Assessment of a single-piece hydrophilic acrylic IOL for piggyback sulcus fixation in pseudophakic cadaver eyes

Abstract: The new IOL has large optic and overall diameters, smooth and undulating haptics, and a convex-concave optic profile. Results show that these characteristics minimize the possibility of interaction with the primary IOL and uveal tissues, decreasing the likelihood of optical aberrations and pigmentary dispersion.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

1
13
1
2

Year Published

2012
2012
2019
2019

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 26 publications
(17 citation statements)
references
References 24 publications
(25 reference statements)
1
13
1
2
Order By: Relevance
“…This explains why, as previously mentioned, the study lens exhibited a greater ILD than the Sulcoflex relative to the primary IOL in cadaver eyes. 23 Our current results did not demonstrate a correlation between ILD and severity of Soemmering's ring, and also no correlation of ILD with primary IOL thickness, which may be due to the relatively small sample size. In a similar cadaver eye study evaluating the Sulcoflex, the ILD appeared mostly dependent on the primary IOL, but it is not known if the correlation was strong as the thickness of the primary IOL was not measured in that study.…”
Section: Discussioncontrasting
confidence: 92%
See 2 more Smart Citations
“…This explains why, as previously mentioned, the study lens exhibited a greater ILD than the Sulcoflex relative to the primary IOL in cadaver eyes. 23 Our current results did not demonstrate a correlation between ILD and severity of Soemmering's ring, and also no correlation of ILD with primary IOL thickness, which may be due to the relatively small sample size. In a similar cadaver eye study evaluating the Sulcoflex, the ILD appeared mostly dependent on the primary IOL, but it is not known if the correlation was strong as the thickness of the primary IOL was not measured in that study.…”
Section: Discussioncontrasting
confidence: 92%
“…In our study, in all cases a satisfactory ILD was found (range: 0.34-1.24 mm). This distance is likely adequate to prevent opacification as our laboratory previously reported the Rayner Sulcoflex to have a smaller ILD of 0.23-0.78 mm also in cadaver eyes, 23 and to our knowledge there do not exist any reports in the literature of ILO with the Sulcoflex lens. Like the add-on lenses currently on the market, the study lens has a convex-concave configuration in order to maximize the ILD.…”
Section: Discussionmentioning
confidence: 68%
See 1 more Smart Citation
“…We describe 2 cases of calcification after Descemet membrane endothelial keratoplasty (DMEK). 9 Of particular interest is that 1 of the calcified IOLs was a sulcus-fixated supplementary IOL [10][11][12] and the other was a hydrophilic acrylic IOL with a hydrophobic surface. 13 To our knowledge, these are the first described cases of calcification with these IOL designs.…”
mentioning
confidence: 99%
“…Kahraman publizierte vielversprechende Ergebnisse mit der Rayner Sulcoflex ® IOL [1] und Gerten präsentierte sehr gute Ergebnisse mit der HumanOptics MS 714 PB ® Linse [2]. In einer In-vitro-Studie zeigte Werner für die Sulcoflex IOL sehr positive anatomische Ergebnisse [3].…”
unclassified