2016
DOI: 10.1016/j.microc.2016.01.009
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of four antimigraine drugs in two ternary mixtures by sweeping-micellar electrokinetic chromatography with retention factor gradient effect and dynamic pH junction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 21 publications
0
9
0
Order By: Relevance
“…Belal et al. reported a simple and specific sweeping‐MEKC method with dynamic pH junction for the analysis of pharmaceutical mixtures containing paracetamol, caffeine, drotaverine and dipyrone. The BGE consisted of 10 mM disodium tetraborate buffer at pH 9.30 with 75 mM SDS.…”
Section: Electrokinetic Chromatography Techniquesmentioning
confidence: 99%
“…Belal et al. reported a simple and specific sweeping‐MEKC method with dynamic pH junction for the analysis of pharmaceutical mixtures containing paracetamol, caffeine, drotaverine and dipyrone. The BGE consisted of 10 mM disodium tetraborate buffer at pH 9.30 with 75 mM SDS.…”
Section: Electrokinetic Chromatography Techniquesmentioning
confidence: 99%
“…In dynamic pH junction‐sweeping , the analytes included drugs , neurotransmitters , nucleosides , amino acids , and food and cosmetic preservatives . The samples were pharmaceutical formulations, food and beverages, and human serum and urine.…”
Section: Sequential Stacking Methodsmentioning
confidence: 99%
“…The samples were pharmaceutical formulations, food and beverages, and human serum and urine. The sample preparations included homogenization and dilution of the food and beverage samples , protein precipitation and further SPE treatment of the biological samples. Detection of the analytes was performed using direct UV or indirect detection at wavelengths of 200–257 nm.…”
Section: Sequential Stacking Methodsmentioning
confidence: 99%
“…The sweeping‐MEKC with dynamic pH junction and RFGE (Retention Factor Gradient Effect) was developed for the simultaneous analysis of four different analytes (i.e., drotaverine hydrochloride and caffeine combined with paracetamol or dipyrone) in pharmaceutical formulations. Signal enhancement of up to eightfold was achieved by the proposed techniques [119]. Simultaneous analysis of tricyclic antidepressant and β‐blockers (i.e., alprenolol, labetalol, and propranolol) in wastewater was also improved using sweeping–MEKC with signal enhancements of up to 305‐fold [120].…”
Section: Strategies For Sensitivity Enhancement In Cementioning
confidence: 99%