2019 IEEE International Ultrasonics Symposium (IUS) 2019
DOI: 10.1109/ultsym.2019.8925588
|View full text |Cite
|
Sign up to set email alerts
|

AlN Checker-mode Resonators with Routing Structures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 12 publications
0
4
0
Order By: Relevance
“…The Q s values and k 2 eff are important parameters for the LWRs, and both of them were extracted based on the measured results by using Equations (5) and (6) [ 22 ]. The Q s value and the k 2 eff of the LWR with d = 12 μm were up to 4019.8 and 0.6%, respectively.…”
Section: Measurement and Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The Q s values and k 2 eff are important parameters for the LWRs, and both of them were extracted based on the measured results by using Equations (5) and (6) [ 22 ]. The Q s value and the k 2 eff of the LWR with d = 12 μm were up to 4019.8 and 0.6%, respectively.…”
Section: Measurement and Discussionmentioning
confidence: 99%
“…The top IDT electrodes are patterned by a 200 nm-thick Al layer, connected to alternate between the ground and RF signals, and the bottom electrodes are patterned by a 200 nm-thick Mo layer. The top IDT electrodes and bottom electrodes are combined to actuate the S0 mode in the AlN film and the frequency of LWRs is mainly dependent on the p of IDTs, which can be expressed in Equation (1) [ 22 ]. For LWRs, the IDTs’ central regions located at the potential maximums and displacement-amplitude minimums can contribute to achieving ideal harmonic conditions.…”
Section: Design and Micro-fabricationmentioning
confidence: 99%
“…The small deviation may have been caused by the fabrication errors of the geometric dimensions and by the slight discrepancy of AlN Young’s modulus between the simulation and the actual fabrication. The effective electromechanical coupling coefficient ( k 2 eff ) can be extracted as 1% via Equation (4) [ 19 ]: …”
Section: Measurement and Discussionmentioning
confidence: 99%
“…27) J. Y. Liu et al found that CKMRs with circle-shaped checker electrodes can achieve a K eff 2 of 5.12% and fewer spurious modes. 28) Here, we design CKMRs with circle-shaped checker electrodes and adopt four types of acoustic excitation configurations. The influence of electrode metallization rate on the K eff 2 is investigated by changing the ratio of the top electrode pad radius (R/r).…”
Section: Introductionmentioning
confidence: 99%