A novel impedimetric disposable immunosensor for rapid detection of a potential cancer biomarker

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
20
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
3
1

Relationship

1
7

Authors

Journals

citations
Cited by 43 publications
(20 citation statements)
references
References 33 publications
0
20
0
Order By: Relevance
“…Likewise, the imaginary portion of the experimental data was used to calculate the real part of a stable, linear, and causal circuit. By this calculation, "Goodness of Fit" values were also procured (Asav and Sezgintürk, 2014;Şimşek et al, 2015). Goodness of fit values can be seen in Supplemental information Table 1.…”
Section: Analytical Characteristics Of the Biosensormentioning
confidence: 99%
“…Likewise, the imaginary portion of the experimental data was used to calculate the real part of a stable, linear, and causal circuit. By this calculation, "Goodness of Fit" values were also procured (Asav and Sezgintürk, 2014;Şimşek et al, 2015). Goodness of fit values can be seen in Supplemental information Table 1.…”
Section: Analytical Characteristics Of the Biosensormentioning
confidence: 99%
“…Lately, nanomaterials based electrochemical immunosensors have become popular since they offer enhanced biomolecule loading capacity to increase the dynamic range of measurements. The technique has been extended by employing various nano-architectured electrode surfaces for determination of several carcinoma biomarkers-CA125 [14,15], human epidermal growth factor receptor [16], human chorionic gonadotropin [17] to biomolecules-interleukin-6 [18] and inorganic molecules-dopamine [19] and okadaic acid [20]. The reports for impedimetric immunosensor for CA125 are limited.…”
Section: Introductionmentioning
confidence: 99%
“…When the I-V behavior of TRIS-PAGE-PGEs and PAGE-PGEs is compared with the PGEs, a reduction in anodic and cathodic current (Figure 3) is demonstrated due to the reduced electron transfer rate of the redoks pair as a result of the polymer coating [16]. The decrease in oxidative and reductive peak current may be due to the changes in load transfer resistance of electrode surface [19,20].…”
Section: Discussionmentioning
confidence: 99%
“…For the electrochemical analysis, 20 mM K 3 [Fe(CN) 6 ] redox pair in phosphate buffer solution was used (redoks-PBS, 137mM NaCl, 2.7mM KCl, 10mM Na 2 HPO 4 , 1.8mM KH 2 PO 4 , pH 7.4) [14][15][16].…”
Section: Materials and Experimental Methodsmentioning