2002
DOI: 10.1016/s0731-7085(01)00554-4
|View full text |Cite
|
Sign up to set email alerts
|

A new HPLC method for azithromycin quantitation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
25
0

Year Published

2003
2003
2017
2017

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 55 publications
(25 citation statements)
references
References 4 publications
0
25
0
Order By: Relevance
“…6 However, the disadvantages of this method are time-consuming and cumbersome, many impact factors and bigger error etc. According to reported, liquid chromatography, [7][8][9][10][11] reverse liquid phase chromatography, 12 UV irradiation 13,14 and liquid chromatography-mass spectrometry (LC-MS) [15][16][17] were used to analyse azithromycin and its related substances. Owing to no conjugated double bonds in the chemical structure of azithromycin, the end absorption just existed in the vicinity of 190-200 nm wavelength.…”
Section: Introductionmentioning
confidence: 99%
“…6 However, the disadvantages of this method are time-consuming and cumbersome, many impact factors and bigger error etc. According to reported, liquid chromatography, [7][8][9][10][11] reverse liquid phase chromatography, 12 UV irradiation 13,14 and liquid chromatography-mass spectrometry (LC-MS) [15][16][17] were used to analyse azithromycin and its related substances. Owing to no conjugated double bonds in the chemical structure of azithromycin, the end absorption just existed in the vicinity of 190-200 nm wavelength.…”
Section: Introductionmentioning
confidence: 99%
“…On the other hand, the development of HPLC methods with UV detection is not a common subject because of the extremely low absorption capacity of the azithromycin in this spectral range. Nevertheless, Zubata et al 15 proposed a simple and lowsensitivity methodology for the azithromycin determination in pharmaceuticals using this approach.…”
Section: Introductionmentioning
confidence: 99%
“…1,2 It is used in respiratory tract infections, like pharyngitis, pneumonia, chronic bronchitis, bronchopneumonia, skin and soft tissue infections and some sexually transmitted diseases. [2][3][4][5] Several methods have been described in the literature for the determination of AZ in pharmaceutical formulations and biological fluids, including spectrophotometry, 2,6-10 spectrofluorometry, 11 voltammetry, 4,5,12,13 high-performance liquid chromatography using electrochemical, 14,15 amperometric, 16 fluorescence, 17 UV, 18,19 and electrospray ionization mass spectrometry, 20 detection and bioassay. 21,22 Some of these methods display good detection limits and accuracy.…”
Section: Introductionmentioning
confidence: 99%
“…21,22 Some of these methods display good detection limits and accuracy. 5,[11][12][13][14][15][16][17][18]20,22 However, most of them are time-consuming 2,4-9,11 -13,15,17,21,22 and in some cases require expensive equipment. 11,[14][15][16][17][18][19][20] The United States Pharmacopeia 23 proposes a chromatographic method with amperometric detection that needs the use of a specific "Gamma-alumina" column, which is expensive and difficult to obtain commercially.…”
Section: Introductionmentioning
confidence: 99%