1994
DOI: 10.1002/bms.1200230807
|View full text |Cite
|
Sign up to set email alerts
|

A highly sensitive assay of melatonin at the femtogram level in human plasma by gas chromatography/negative ion chemical ionization mass spectrometry

Abstract: A highly sensitive and specific assay was developed for routine analysis of melatonin at the femotogram level in human plasma. Melatonin and the deuterated internal standard [(2H4)melatonin] were measured by gas chromatography/negative ion chemical ionization mass spectrometry with methane as the reagent gas. A simple liquid-liquid extraction procedure was used to isolate the two compounds of interest from the complex biological matrix. Melatonin was converted to the fluorinated derivative with pentafluoroprop… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
34
0

Year Published

1999
1999
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 54 publications
(35 citation statements)
references
References 15 publications
(1 reference statement)
1
34
0
Order By: Relevance
“…Until now, various analytical methods, such as enzyme immunoassay, [18][19][20][21]28 GC-MS [22][23][24] and HPLC methods, [25][26][27]29,30 have been reported for the determination of melatonin. Enzymatic methods (both RIA and ELISA) are frequently used, and various assay kits are commercially available.…”
Section: Development Of a Fully-automated On-line Oxidation Columnswimentioning
confidence: 99%
See 3 more Smart Citations
“…Until now, various analytical methods, such as enzyme immunoassay, [18][19][20][21]28 GC-MS [22][23][24] and HPLC methods, [25][26][27]29,30 have been reported for the determination of melatonin. Enzymatic methods (both RIA and ELISA) are frequently used, and various assay kits are commercially available.…”
Section: Development Of a Fully-automated On-line Oxidation Columnswimentioning
confidence: 99%
“…However, enzymatic immunoassays are widely known to show crossreactions or non-specific bindings, [17][18][19][20][21]28 especially for the determination of trace amounts of an analyte like melatonin. GC-MS methods with N-trimethylsilyl or pentafluoropropionic derivatization are sensitive, [22][23][24] however, both derivatization procedures require skillful techniques. Concerning HPLC, various methods combining an electrochemical detector, 25 a fluorescence detector 26 or MS 27,29,30 have been reported.…”
Section: Development Of a Fully-automated On-line Oxidation Columnswimentioning
confidence: 99%
See 2 more Smart Citations
“…There are many methods reported for quantification of melatonin with different kind of matrix like plasma, saliva, pineal gland and biological samples by GC-MS Chemical ionisation (Fourtillan et al 1994), LC-MS/MS (Eriksson et al 2003;Cao et al 2006), GC-ECD (Greiner and Chan 1978), HPLC-FLD (Rizzo et al 2002;Vitale et al 1996;Iinuma et al 1999;Munoz et al 2009;Lizuka et al 2007;Itoh et al 1997), HPLC-Electrochemical detector (Chanut et al 1998) and HPLC chemiluminesence (Lu et al 2002). Melatonin in human milk was reported by RIA and the method was validated by GC-MS (Illnerova et al 1993).…”
Section: Introductionmentioning
confidence: 99%