1999
DOI: 10.1002/(sici)1099-0801(199902)13:1<24::aid-bmc765>3.0.co;2-i
|View full text |Cite
|
Sign up to set email alerts
|

Capillary gc-ms determination of melatonin in several pharmaceutical tablet formulations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0

Year Published

2000
2000
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(4 citation statements)
references
References 12 publications
0
3
0
Order By: Relevance
“…Melatonin was extracted using a method developed based on published protocols. [48][49][50][51] Briefly, about 300 mg of D. citri adults was homogenized to fine powder using 200 μL of ethyl acetate containing 100 mg L −1 butylated hydroxytoluene (as an antioxidant). After total homogenization, additional 550 μL of ethyl acetate was added.…”
Section: Melatonin Extraction and Purificationmentioning
confidence: 99%
“…Melatonin was extracted using a method developed based on published protocols. [48][49][50][51] Briefly, about 300 mg of D. citri adults was homogenized to fine powder using 200 μL of ethyl acetate containing 100 mg L −1 butylated hydroxytoluene (as an antioxidant). After total homogenization, additional 550 μL of ethyl acetate was added.…”
Section: Melatonin Extraction and Purificationmentioning
confidence: 99%
“…Although a good agreement between the two methods was obtained, a larger blood sample was needed for the headspace method (500 mL). More recently, Aboul-Enein et al (1999) reported a simple capillary GC-MS for the determination of the pineal gland hormone, melatonin, in pharmaceutical preparations. Excellent reproducibility was obtained by the splitless injection with an RSD of AE2%.…”
Section: Gc-msmentioning
confidence: 99%
“…Over the past decades, MT analysis has gained increasing significance, where confirmatory techniques, such as radioimmunoassay [11], calorimetry [12], enzyme-linked immunoassay [13], high-resolution nuclear magnetic resonance spectroscopy [14], highperformance liquid chromatography [15,16], mass spectrometry [17,18], and electrochemical approaches [19], have been used to detect MT levels. However, owing to the low concentrations of MT (0.043 µM in the day and 0.86 µM in the night [20]) and co-existence of several endogenous metabolites in biological fluids, the accurate detection of MT at low concentrations with sufficient anti-interference ability remains a challenge.…”
Section: Introductionmentioning
confidence: 99%