2015
DOI: 10.1007/s13361-015-1275-y
|View full text |Cite
|
Sign up to set email alerts
|

3D ToF-SIMS Analysis of Peptide Incorporation into MALDI Matrix Crystals with Sub-micrometer Resolution

Abstract: Abstract. The analytical sensitivity in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is largely affected by the specific analyte-matrix interaction, in particular by the possible incorporation of the analytes into crystalline MALDI matrices. Here we used time-of-flight secondary ion mass spectrometry (ToF-SIMS) to visualize the incorporation of three peptides with different hydrophobicities, bradykinin, Substance P, and vasopressin, into two classic MALDI matrices, 2,5-dihydroxybenz… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
39
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 34 publications
(41 citation statements)
references
References 34 publications
(44 reference statements)
2
39
0
Order By: Relevance
“…2A). Nor-GGG-YIGSR peptide positive ion fragment signals were identified and were corroborated to literature 30,31 (see fragment structures of identified signals in Fig. S23 †).…”
Section: Electrospun Scaffold Fabrication and Characterisationsupporting
confidence: 80%
“…2A). Nor-GGG-YIGSR peptide positive ion fragment signals were identified and were corroborated to literature 30,31 (see fragment structures of identified signals in Fig. S23 †).…”
Section: Electrospun Scaffold Fabrication and Characterisationsupporting
confidence: 80%
“…Interestingly, alternative ionization methods (e.g., SIMS) have been used to characterize the analyte incorporation into spots and, although difficult to implement, similar imaging-based studies would be interesting. 25 Homogenous application has also been a major focus, and researchers have utilized alternative application methods to improve this facet in the past few years. One example is electrospray deposition, for which units tend to be home-built.…”
Section: Sample Preparationmentioning
confidence: 99%
“…During the preparation of the MALDI sample, SOMs incorporate the analyte into their crystal lattice, and ideally, a homogenous and defect free crystal lattice is targeted to ensure a high ionization efficiency and successful measurements, and the correlation between the matrix crystal forms and the analyte signal distribution was intensively studied . Crystal formation and analyte incorporation are influenced by the sample preparation method and several method related parameters; e. g. it was reported that the commonly used air‐dried‐droplet method leads to poor homogeneity, while electrospray sample preparation gives evenly sized matrix crystals with well‐distributed analyte incorporation . Furthermore, a low vapor pressure of the used solvent and a longer drying time improves the crystal formation and promotes homogeneous incorporation of the analyte .…”
Section: Introductionmentioning
confidence: 99%