2003
DOI: 10.1590/s0104-11692003000600005
|View full text |Cite
|
Sign up to set email alerts
|

Alterações morfológicas em traquéias de pacientes intubados em função do tempo de intubação

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0
3

Year Published

2006
2006
2014
2014

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 15 publications
(9 reference statements)
0
2
0
3
Order By: Relevance
“…These values are considered safe to prevent ischemic injuries and other important early tracheal mucosa changes, such as cell edema, loss of cilia and epithelium desquamation, which may be triggered by cuff hyperinflation. (6) Laryngeal and tracheal stenosis after intubation ranges between 1.5% and 19%. (7) For some authors (8) the form to prevent or minimize future injuries is to inflate the cuff with the minimal effective pressure, just enough to seal the trachea and prevent air leakage during ventilation, without surpassing 25 cmH 2 O, the threshold value for tracheal mucosa perfusion.…”
mentioning
confidence: 99%
“…These values are considered safe to prevent ischemic injuries and other important early tracheal mucosa changes, such as cell edema, loss of cilia and epithelium desquamation, which may be triggered by cuff hyperinflation. (6) Laryngeal and tracheal stenosis after intubation ranges between 1.5% and 19%. (7) For some authors (8) the form to prevent or minimize future injuries is to inflate the cuff with the minimal effective pressure, just enough to seal the trachea and prevent air leakage during ventilation, without surpassing 25 cmH 2 O, the threshold value for tracheal mucosa perfusion.…”
mentioning
confidence: 99%
“…Estas normalmente apresentam um balonete, denominado cuff 2,4,5 , em sua extremidade inferior, com o objetivo de garantir a ventilação pulmonar adequada sem permitir escape aéreo 2,3,7,8,[10][11][12][13][14][15][16] , e evitar a aspiração de conteúdo orofaríngeo e gastroesofágico para os pulmões, 2,3,8,[10][11][12][13][16][17][18][19] uma causa comum de pneumonia. 2,10,12,13,16,17,20,21 A pressão intracuff transmitida para a traquéia é lesiva 3,5,11,13,14 , principalmente quando o ajuste é feito de forma inadequada, além dos valores considerados seguros, podendo ocorrer lesões ainda mais importantes na parede da traquéia justaposta ao cuff [2][3][4][5]11,13,14,[16][17][18][19]22 . É recomendado que a insuflação do cuff seja feita...…”
unclassified
“…Ainda não há consenso quanto ao valor máximo de pressão no balonete do tubo traqueal. A fi m de minimizar a isquemia da mucosa, a pressão deve fi car entre 20-25 mmHg, pressão esta menor que a capilar pulmonar, que é em torno de 25-30 mmHg [15][16][17][18][19][20][21] . Salientamos que essa peculiaridade anatômica facilita a mobilização do TOT, propiciando a extubação acidental ou intubação seletiva.…”
Section: Resultados E Análise Dos Dadosunclassified