Estudo multicêntrico dos resultados das trocas valvares com o uso da bioprótese Biocor no Estado de Minas Gerais

Abstract: Centros do Estado de Minas Gerais. Este estudo inclui somente a análise dos pacientes submetidos a troca valvar aórtica (n = 603) e mitral (n = 1110), isoladamente. Neste grupo (n = 1713), a mortalidade hospitalar foi de 104 pacientes (6,1%). Dos 1609 pacientes que receberam alta do hospital, conseguimos o seguimento de 1101 pacientes (64,3). Esta análise corresponde a um período de 1 a 84 meses, com média de 48 meses e com um seguimento cumulativo de : aórticas (n = 385) = 1230 pacientes/ano ; mitrais (n = 71… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0
2

Year Published

2005
2005
2021
2021

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 20 publications
(1 reference statement)
0
4
0
2
Order By: Relevance
“…Initial tests in a pulse simulator identified the possibility of early structural failure [10], but changes in the project and in the technique of tissue preparation gave favorable hemodynamic and clinical results [11,12]. Their use in Brazil was publicized by Braile et al [13] and the St Jude Medical-Biocor TM prosthesis (SJM-Biocor TM ) was introduced in 1982 [14]. This model incorporates structural changes in the pericardial membrane that give a better durability and a satisfactory hemodynamical result [6].…”
Section: Introductionmentioning
confidence: 99%
“…Initial tests in a pulse simulator identified the possibility of early structural failure [10], but changes in the project and in the technique of tissue preparation gave favorable hemodynamic and clinical results [11,12]. Their use in Brazil was publicized by Braile et al [13] and the St Jude Medical-Biocor TM prosthesis (SJM-Biocor TM ) was introduced in 1982 [14]. This model incorporates structural changes in the pericardial membrane that give a better durability and a satisfactory hemodynamical result [6].…”
Section: Introductionmentioning
confidence: 99%
“…Initial tests in a pulse simulator identified the possibility of early structural failure [10], but changes in the project and in the technique of tissue preparation gave favorable hemodynamic and clinical results [11,12]. Their use in Brazil was publicized by Braile et al [13] and the St Jude Medical-Biocor TM prosthesis (SJM-Biocor TM ) was introduced in 1982 [14]. This model incorporates structural changes in the pericardial membrane that give a better durability and a satisfactory hemodynamical result [6].…”
Section: Introductionmentioning
confidence: 99%
“…It can be observed in most of existing publications that the risk of reoperation begins to grow after 10 years of surgery to implant of valve substitute, probably due to dysfunction of the prosthesis, and increases progressively over time, decreasing with advancing age [17,24,26,32,[36][37][38][39][40][41][42]. In this cohort, a trend was observed for reoperation after 10 years of follow-up (P=0.057), which is probably at the borderline sample descriptive level.…”
Section: Reoperationmentioning