2002
DOI: 10.1590/s0004-282x2002000500015
|View full text |Cite
|
Sign up to set email alerts
|

Valor preditivo da dor à compressão do globo ocular nas síndromes meníngeas

Abstract: RESUMO -As síndromes meníngeas podem ser bem avaliadas clinicamente através dos sinais clássicos de irritação meníngea com boa sensibilidade e especificidade, apesar de algumas limitações. Nesse estudo, foi avaliada a dor à compressão do globo ocular (DCGO) como sinal propedêutico nas síndromes meníngeas. Foram estudados 160 pacientes de ambos os gêneros e com ampla distribuição etária, distribuídos em dois grupos: grupo I, de portadores de síndrome meníngea; grupo II, sem síndrome meníngea . No grupo I (n=80)… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0
2

Year Published

2005
2005
2022
2022

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 8 publications
(7 reference statements)
0
3
0
2
Order By: Relevance
“…KamLAND is a first experiment to deal with these solar neutrino parameters completely from manufactured source instead of from the sun. This reactor neutrino experiment convinces scientists that the Large Mixing MSW is the solution of the solar neutrino problem [10,12,13].…”
Section: Manufactured Neutrinosmentioning
confidence: 86%
See 1 more Smart Citation
“…KamLAND is a first experiment to deal with these solar neutrino parameters completely from manufactured source instead of from the sun. This reactor neutrino experiment convinces scientists that the Large Mixing MSW is the solution of the solar neutrino problem [10,12,13].…”
Section: Manufactured Neutrinosmentioning
confidence: 86%
“…So, we uses free 8 B flux method [10], i.e., we float the flux near the central value given in paper [11] within 1σ uncertainty range, then find out which flux gives the minimal χ 2 . The χ 2 formula changes a little as…”
Section: Solar Neutrinosmentioning
confidence: 99%
“…A previous study reported the sensitivity and specificity (respectively) of meningeal tests as follows: nuchal rigidity (46.1%, 71.3%), jolt accentuation test (52.4%, 71.1%), Kernig's sign (22.9%, 91.2%), and Brudzinski's sign (27.5%, 88.8%). 2 The ocular globe compression sign (applying digital pressure to both eyeballs and observing the presence and degree of pain reaction to the stimulus) was proposed in 2002, 3 and has a sensitivity and specificity of 34.5% and 78.6%, respectively. 4 In our patient, all the meningeal signs, except for the ocular globe compression sign, were negative.…”
Section: Discussionmentioning
confidence: 99%
“…Foi proposto por Holanda 6 e Holanda e cols 7 , que a dor à compressão do globo ocular (DCGO), a exemplo dos sinais clássicos de irritação meníngea, pode ser facilmente pesquisada nos pacientes com síndrome meníngea. Esse sinal propedêutico alcançou, naquele estudo 6 7 , sensibilidade de 97,5%, especificidade de 98,8%, valor preditivo positivo de 98,7% e valor preditivo negativo de 98,1%.…”
unclassified
“…Esses resultados, no entanto, devem ser analisados com cautela, pois a literatura médica não faz qualquer referência a esse sinal, além de que o trabalho 6 7 é passível de críticas metodológicas. Por isso, o presente estudo foi realizado para avaliar a DCGO em portadores de síndrome meníngea infecciosa, seguindo metodologia diferente do pioneiro estudo de Holanda 6 . O estudo foi de corte transversal, para validação diagnóstica, e mantendo os 2 observadores desinformados dos resultados observados entre si.…”
unclassified