2014
DOI: 10.1590/1678-775720140209
|View full text |Cite
|
Sign up to set email alerts
|

Radiopacity and cytotoxicity of Portland cement associated with niobium oxide micro and nanoparticles

Abstract: Objective Mineral Trioxide Aggregate (MTA) is composed of Portland Cement (PC) and bismuth oxide (BO). Replacing BO for niobium oxide (NbO) microparticles (Nbµ) or nanoparticles (Nbη) may improve radiopacity and bioactivity. The aim of this study was to evaluate the radiopacity and cytotoxicity of the materials: 1) PC; 2) White MTA; 3) PC+30% Nbµ; 4) PC+30% Nbη.Material and Methods For the radiopacity test, specimens of the different materials were radiographed along an aluminum step-wedge. For cell culture as… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
16
0
3

Year Published

2016
2016
2021
2021

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(21 citation statements)
references
References 26 publications
2
16
0
3
Order By: Relevance
“…CSC + Nb 2 O 5 had increased ALP activity compared with MTA, demonstrating mineralization potential (Mestieri et al . ).…”
Section: Introductionmentioning
confidence: 97%
See 1 more Smart Citation
“…CSC + Nb 2 O 5 had increased ALP activity compared with MTA, demonstrating mineralization potential (Mestieri et al . ).…”
Section: Introductionmentioning
confidence: 97%
“…Mestieri et al . () showed CSC + Nb 2 O 5 had stable Saos‐2 cell viability and stimulation of alkaline phosphatase (ALP) activity after 7 days of material exposure in a different study. CSC + Nb 2 O 5 had increased ALP activity compared with MTA, demonstrating mineralization potential (Mestieri et al .…”
Section: Introductionmentioning
confidence: 99%
“…It is known that dentin of 1 mm thickness is equivalent to an 1 mm aluminum scale, meaning that the material should have a radiopacity of at least 3 mm Al. 13,[18][19][20] Although these specifications are actually for sealers, they are an equivalence based on the fact that both materials will be in contact with periodontal and periapical tissues under clinical conditions. 18 The aluminum step-wedge is widely used to measure the radiopacity of the material and its measurement made through digital software minimizes potential errors due to visual acuity.…”
Section: Discussionmentioning
confidence: 99%
“…ISO 6876/2001 standards established that endodontic filling materials should present radiopacity higher than 3.0 mm Al. According to ANSI/ADA, endodontic cements should be at least 2.0 mm Al more radiopaque than dentin or bone 7 .…”
Section: Introductionmentioning
confidence: 99%