We present in-line coating thickness measurements acquired simultaneously using 2 independent sensing modalities: terahertz pulsed imaging (TPI) and optical coherence tomography (OCT). Both techniques are sufficiently fast to resolve the coating thickness of individual pharmaceutical tablets in situ during the film coating operation, and both techniques are direct structural imaging techniques that do not require multivariate calibration. The TPI sensor is suitable to measure coatings greater than 50 μm and can penetrate through thick coatings even in the presence of pigments over a wide range of excipients. Due to the long wavelength, terahertz radiation is not affected by scattering from dust within the coater. In contrast, OCT can resolve coating layers as thin as 20 μm and is capable of measuring the intratablet coating uniformity and the intertablet coating thickness distribution within the coating pan. However, the OCT technique is less robust when it comes to the compatibility with excipients, dust, and potentially the maximum coating thickness that can be resolved. Using a custom-built laboratory scale coating unit, the coating thickness measurements were acquired independently by the TPI and OCT sensors throughout a film coating operation. Results of the in-line TPI and OCT measurements were compared against one another and validated with off-line TPI and weight gain measurements. Compared with other process analytical technology sensors, such as near-infrared and Raman spectroscopy, the TPI and OCT sensors can resolve the intertablet thickness distribution based on sampling a significant fraction of the tablet populations in the process. By combining 2 complementary sensing modalities, it was possible to seamlessly monitor the coating process over the range of film thickness from 20 μm to greater than 250 μm.
Spectral domain optical coherence tomography (OCT) has recently attracted a lot of interest in the pharmaceutical industry as a fast and non-destructive modality for quantification of thin film coatings that cannot easily be resolved with other techniques. Because of the relative infancy of this technique, much of the research to date has focused on developing the in-line measurement technique for assessing film coating thickness. To better assess OCT for pharmaceutical coating quantification, this paper evaluates tablets with a range of film coating thickness measured using OCT and terahertz pulsed imaging (TPI) in an off-line setting. In order to facilitate automated coating quantification for film coating thickness in the range of 30–200 μm, an algorithm that uses wavelet denoising and a tailored peak finding method is proposed to analyse each of the acquired A-scan. Results obtained from running the algorithm reveal an increasing disparity between the TPI and OCT measured intra-tablet variability when film coating thickness exceeds 100 μm. The finding further confirms that OCT is a suitable modality for characterising pharmaceutical dosage forms with thin film coatings, whereas TPI is well suited for thick coatings. © 2015 The Authors. Journal of Pharmaceutical Sciences published by Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci 104:3377–3385, 2015
Layer 3 (a) Input BSSRDF (b) Layered material volume (c) Fabricated Material Volume Figure 1: Our system automatically generates a layered material volume for approximating a custom BSSRDF. (a)The appearance of a real material sample under diffuse lighting and a beam light. (b)A collection of layers generated by our system for assembling the output volume. (c) The appearance of the fabricated material volume under the same diffuse lighting and beam light. AbstractMany real world surfaces exhibit translucent appearance due to subsurface scattering. Although various methods exists to measure, edit and render subsurface scattering effects, no solution exists for manufacturing physical objects with desired translucent appearance. In this paper, we present a complete solution for fabricating a material volume with a desired surface BSSRDF. We stack layers from a fixed set of manufacturing materials whose thickness is varied spatially to reproduce the heterogeneity of the input BSSRDF. Given an input BSSRDF and the optical properties of the manufacturing materials, our system efficiently determines the optimal order and thickness of the layers. We demonstrate our approach by printing a variety of homogenous and heterogenous BSSRDFs using two hardware setups: a milling machine and a 3D printer. 62:8 • Y. Dong et al.
Full-field optical coherence tomography (FF-OCT) using a conventional light-emitting diode and a complementary metal-oxide semiconductor camera has been developed for characterising coatings on small pellet samples. A set of en-face images covering an area of 700 × 700 μm(2) was taken over a depth range of 166 μm. The three-dimensional structural information, such as the coating thickness and uniformity, was subsequently obtained by analysis of the recorded en-face images. Drug-loaded pharmaceutical sustained-release pellets with two coating layers and of a sub-millimetre diameter were studied to demonstrate the usefulness of the developed system. We have shown that both coatings can be clearly resolved and the thickness was determined to be 40 and 50 μm for the outer and inner coating layers, respectively. It was also found that the outer coating layer is relatively uniform, whereas the inner coating layer has many particle-like features. X-ray computed microtomography measurements carried out on the same pellet sample confirmed all these findings. The presented FF-OCT approach is inexpensive and has better spatial resolution compared with other non-destructive analysis techniques such as terahertz pulsed imaging, and is thus considered advantageous for the quantitative analysis of thin coatings on small pellet samples.
1. Increasing evidence indicates that hydrogen sulphide (H₂S) may serve as an important biological cytoprotective agent. Heat shock protein (Hsp) 90 can attenuate stress-induced injury. However, whether Hsp90 mediates the cytoprotective effect of H₂S against chemical hypoxia-induced injury in PC12 cells is not known. 2. In the present study, CoCl₂ (a chemical hypoxia mimetic) was used to treat PC12 cells to create a model of chemical hypoxia. To explore the role of Hsp90 in the cytoprotection afforded by H₂S against chemical hypoxia-induced injury, 2 μmol/L 17-allylaminogeldanamycin (17-AAG), a selective inhibitor of Hsp90, was administered for 30 min prior to preconditioning with 400 μmol/L NaHS, followed by chemical hypoxia. 3. Cobalt chloride reduced cell viability (by 52.7 ± 1.5%), increased PC12 cell apoptosis (by 42.1 ± 1.5%), induced reactive oxygen species (ROS) by 3.79% compared with control and induced the dissipation of mitochondrial membrane potential (MMP) by 2.56% compared with control. 4. Pretreatment of PC12 cells with 100-400 μmol/L sodium hydrosulphide (NaHS), an H₂S donor, for 3 h prior to exposure to 600 μmol/L CoCl₂ provided significant, concentration-dependant protection to PC12 cells against CoCl₂-induced cytotoxicity. Specifically, pretreatment of PC12 cells with 400 μmol/L NaHS decreased apoptosis to 16.77 ± 1.77% and blocked the CoCl₂-induced increase in ROS production and loss of MMP. 5. At 400 μmol/L, NaHS upregulated Hsp90 in a time-dependant manner (over the period 0-180 min). In addition to its effects on Hsp90 expression, NaHS pretreatment of PC12 cells augmented the overexpression of Hsp90 induced by 600 μmol/L CoCl₂ by 1.38-fold (P < 0.01). 6. Treatment of PC12 cells with 2 μmol/L 17-AAG for 30 min prior to NaHS pretreatment blocked the overexpression of Hsp90 induced by NaHS preconditioning, as evidenced by decreased cell viability (by 54.2 + 1.2%; P < 0.01), increased PC12 cell apoptosis (by 36.6 ± 1.2%; P < 0.01) and increasing ROS production. 7. The findings of the present study provide novel evidence that Hsp90 mediates H₂S-induced neuroprotection against chemical hypoxia-induced injury via anti-oxidant and anti-apoptotic effects.
We report the development of a Spectral Domain Line Field Optical Coherence Tomography (LF-OCT) system, using a broad bandwidth and spatial coherent Super-Continuum (SC) source. With conventional quasi-Continuous Wave (CW) setup we achieve axial resolutions up to 2.1 μm in air and 3D volume imaging speeds up to 213 kA-Scan/s. Furthermore, we report the use of a single SC pulse, of 2 ns duration, to temporally gate an OCT B-Scan image of 70 A-Scans. This is the equivalent of 35 GA-Scans/s. We apply the CW setup for high resolution imaging of the fine structures of a human cornea sample ex-vivo. The single pulse setup is applied to imaging of a coated pharmaceutical tablet. The fixed pattern noise due to spectral noise is removed by subtracting the median magnitude A-Scan. We also demonstrate that the Fourier phase can be used to remove aberration caused artefacts.
Optical coherence tomography (OCT) can monitor human donor corneas non-invasively during the de-swelling process following storage for corneal transplantation, but currently only resultant thickness as a function of time is extracted. To visualize and quantify the mechanism of de-swelling, we present a method exploiting the nanometer sensitivity of the Fourier phase in OCT data to image deformation velocities. The technique was demonstrated by non-invasively showing during de-swelling that osmotic flow through an intact epithelium is negligible and removing the endothelium approximately doubled the initial flow at that interface. The increased functional data further enabled the validation of a mathematical model of the cornea. Included is an efficient method of measuring high temporal resolution (1 minute demonstrated) corneal thickness, using automated collection and semi-automated graph search segmentation. These methods expand OCT capabilities to measure volume change processes for tissues and materials.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.