The purpose of this study was to determine the performance of low-dose computed tomography (CT) scanning with integrated circuit (IC) detector in defining fine structures of temporal bone in children by comparing with the conventional detector.The study was performed with the approval of our institutional review board and the patients’ anonymity was maintained. A total of 86 children <3 years of age underwent imaging of temporal bone with low-dose CT (80 kV/150 mAs) equipped with either IC detector or conventional discrete circuit (DC) detector. The image noise was measured for quantitative analysis. Thirty-five structures of temporal bone were further assessed and rated by 2 radiologists for qualitative analysis. κ Statistics were performed to determine the agreement reached between the 2 radiologists on each image. Mann–Whitney U test was used to determine the difference in image quality between the 2 detector systems.Objective analysis showed that the image noise was significantly lower (P < 0.001) with the IC detector than with the DC detector. The κ values for qualitative assessment of the 35 fine anatomical structures revealed high interobserver agreement. The delineation for 30 of the 35 landmarks (86%) with the IC detector was superior to that with the conventional DC detector (P < 0.05) although there were no differences in the delineation of the remaining 5 structures (P > 0.05).The low-dose CT images acquired with the IC detector provide better depiction of fine osseous structures of temporal bone than that with the conventional DC detector.
Background Isthmic spondylolisthesis (IS) is a common clinical disease with a high incidence rate. However, most current researches explain the clear pathogenesis from a single perspective. The aim of our study was to explore the relationships between multiple parameters in patients and find the potential risk factors of this disease. Methods Our study retrospectively included 115 patients who were diagnosed with isthmic spondylolisthesis and the same number of individuals without spondylolisthesis. The following parameters were measured or collected: age, pelvic incidence (PI), facet joint angle (FJA) and pedicle-facet angle (P-F angle). The radiographic files were imported into Mimics Medical 20.0 and all collected data were analyzed using SPSS, version 26.0, statistical software. Results The age was higher in IS group than in control group. PI was also higher in the IS group (50.99 ± 7.67) than in the control group (43.77 ± 9.30) significantly (P = 0.009). There was significant difference in cranial and average FJA tropism in L3-L4 level (P = 0.002, P = 0.006, respectively) and in L4-L5 level (P < 0.001). P-F angle of L4-L5 level showed significantly larger in IS group than in control group (P = 0.007).The logistic regression analysis showed a larger age, a greater L3-L4 cranial FJA tropism, and a greater L4-L5 cranial FJA tropism were potential predictors of IS, with an OR of 1.07, 1.28, and 1.39 respectively. The thresholds of the predictors were 60 years, 5.67°, and 8.97° according to the ROC curve. The linear regression equation was established: degree of slippage (%) = 0.220*age − 0.327* L3-4 cranial FJA tropism − 0.346* L4-5 average FJA tropism (F = 3.460, P = 0.011, r = 0.659). Conclusions Our study revealed that isthmic spondylolisthesis may be related to multiple factors rather than a single factor. Age, PI, PJA and P-F angle are potentially associated with spondylolisthesis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.