Anterior and posterior corneal surface height data obtained by elevation-based tomography provide useful information in improving keratoconus diagnostic accuracy and in grading the severity of keratoconus.
Aspherical- and multi-curve rigid gas-permeable hard contact lenses (HCLs) have a flattened curve in the peripheral zone and are mostly used for patients with keratoconus who cannot wear glasses, soft contact lenses, or spherical HCLs. In this retrospective study, a total of 95 eyes of 77 patients who used aspherical- or multi-curve HCLs (mean age: 40.0 ± 11.0 years) were evaluated. This study examined the types of aspherical- and multi-curve HCLs, best-corrected visual acuity (BCVA) values before and after wearing HCLs, the association with the Amsler-Krumeich classification, duration of wear, corneal/conjunctival disorder, and the frequency of changing HCLs. There were 78 eyes that used aspherical-curve HCLs and 17 that used multi-curve HCLs. BCVA significantly improved from 0.42 logMAR to 0.06 logMAR after wearing either form of HCL. The Amsler-Krumeich classification showed that aspherical-curve HCLs were commonly used for patients with stage 2 keratoconus, and multi-curve HCLs were commonly used for stage 4 patients. The BCVA values were worse when the disease stage was more severe (stages 3 and 4) regardless of HCL type. The mean base curve of the lenses was steeper in multi-curve HCLs than in aspherical-curve HCLs. The more severe the disease stage, the steeper the base curve in both aspherical- and multi-curve HCLs. The duration of wear significantly improved from 2.1 h to 10.2 h, and corneal/conjunctival disorder similarly improved. The mean frequency of changing HCL types was 1.1 times. This study suggests that a flat peripheral curve design with aspherical- and multi-curve HCLs is useful for patients with keratoconus.
Two cases involving retinal detachment caused by breaks in the pars plicata of the ciliary body are presented. In both, retinal detachment developed following surgery for atopic cataract. The residual lens capsules contracted with evidence of fibrotic change. Nonpigmented ciliary epithelium appeared to have become detached and torn by traction through the zonules of Zinn.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.