BackgroundOnly limited data on the prevalence of iron deficiency (ID) and its correlation with clinical parameters are available in cancer. ID frequently contributes to the pathogenesis of anemia in patients with cancer and may lead to several symptoms such as impaired physical function, weakness and fatigue.Patients and methodsParameters of iron status and clinical parameters were evaluated in 1528 patients with cancer who presented consecutively within a four-month period at our center. One thousand fifty-three patients had solid tumors and 475 hematological malignancies.ResultsID [transferrin saturation (TSAT) < 20%] was noted in 645 (42.6%) of the 1513 patients with TSAT tests available and 500 (33.0%) were anemic. ID rates were highest in pancreatic (63.2%), colorectal (51.9%) and lung cancers (50.7%). Of the 409 iron-deficient patients in whom serum ferritin levels were available additionally to TSAT, 335 (81.9%) presented with functional ID (FID) (TSAT < 20%, serum ferritin ≥30 ng/ml) and 74 (18.1%) with absolute ID. In patients with solid tumors, prevalence of ID correlated with cancer stage at diagnosis (P = 0.001), disease status (P = 0.001) and ECOG performance status (P = 0.005).ConclusionsID was frequently noted in cancer and was associated with advanced disease, close proximity to cancer therapy, and poor performance status in patients with solid tumors.
The novel heavy/light chain (HLC) assay was used for the detection and measurement of monoclonal immunoglobulins, response evaluation and prognostication. This test allows identification and quantification of the different light chain types of each immunoglobulin class (for example, IgGκ and IgGλ) and enables calculation of ratios of monoclonal/polyclonal immunoglobulin (HLC ratio). Sequential sera of 156 patients with IgG or IgA myeloma started on first-line therapy and followed for a median of 46.1 months were analyzed. Results were compared with those obtained with conventional techniques (serum protein electrophoresis (SPEP), immunofixation electrophoresis (IFE), nephelometry (NEPH), and the free light chain test (FLC)). Our data show that the HLC assay allowed quantification of monoclonal proteins not accurately measurable by SPEP or NEPH. When both HLC and FLC testing were applied for response assessment, clonal excess was noted in 14/31 patients with complete response (CR). HLC ratio indicated presence of disease in 8/31 patients who achieved CR and, in sequential studies indicated evolving relapse in three patients before IFE became positive. Highly abnormal HLC ratios at presentation were significantly associated with shorter overall survival (40.5 months vs median not reached, P=0.016). Multivariate analysis revealed HLC ratio (P=0.03) and β2-microglobulin (P<0.01) as independent risk factors for survival.
In this study, an elevated KFLC-index represented the most sensitive and specific quantitative diagnostic parameter for MS. As it is measured by automated, routinely available laboratory methods, KFLC quantitation can provide a rapid and reproduceable indication of intrathecal immunological processes supporting current MS diagnostic criteria.
Heavy light chain (HLC) assays allow precise measurement of the monoclonal and of the noninvolved polyclonal immunoglobulins of the same isotype as the M‐protein (e.g., monoclonal IgAκ and polyclonal IgAλ in case of an IgAκ myeloma), which was not possible before. The noninvolved polyclonal immunoglobulin is termed ‘HLC‐matched pair’. We investigated the impact of the suppression of the HLC‐matched pair on outcome in 203 patients with multiple myeloma, a phenomenon that likely reflects the host's attempt to control the myeloma clone. Severe (>50%) HLC‐matched pair suppression was identified in 54.5% of the 156 newly diagnosed patients and was associated with significantly shorter survival (45.4 vs. 71.9 months, P = 0.019). This correlation was statistically significant in IgG patients (46.4 vs. 105.1 months, P = 0.017), but not in patients with IgA myelomas (32.9 vs. 54.1 months, P = 0.498). At best response, HLC‐matched pair suppression improved only in patients with ≥VGPR, indicating partial or complete humoral immune reconstitution during remission in those with excellent response. Severe HLC‐matched pair suppression retained its prognostic impact also during follow‐up after first response. In the 47 pretreated patients with relapsed/refractory disease, a similar correlation between severe HLC suppression and survival was noted (22.8 vs. not reached, P = 0.028). Suppression of the polyclonal immunoglobulins of the other isotypes than the myeloma protein correlated neither with HLC‐matched pair suppression, nor with outcome. Multivariate analysis identified severe HLC‐matched pair suppression as independent risk factor for shorter survival, highlighting the impact of isotype specific immune dysregulation on outcome in multiple myeloma. Am. J. Hematol. 91:295–301, 2016. © 2015 The Authors. American Journal of Hematology Published by Wiley Periodicals, Inc.
In the present phase II study, we tested the efficacy of a single course of rituximab (375 mg/m2 on days 1, 8, 15 and 22) as treatment for relapsed myeloma. The rationale for this study was the identification of a population of clonotypic CD20+ B cells that are believed to be precursors of malignant plasma cells. In addition, CD20 was expressed on 10% and 50% of bone marrow plasma cells in two of the ten patients enrolled. Following rituximab treatment, none of the patients achieved an objective response. Two patients had stable disease at month 6, the predefined end of the study, while, at that time, two patients were classified as having progressive disease. One patient opted to withdraw from the study at month 3, at which time he had stable disease. The other five patients had to be withdrawn early from the post-treatment observation because of need of salvage therapy for progressive disease. WHO grade
SummaryReduced antiplatelet effect of clopidogrel assessed with multiple electrode aggregometry (MEA) and vasodilator stimulated phosphoprotein-phosphorylation (VASP-P) assay has been proven to predict major adverse cardiovascular events (MACE) after coronary stenting. So far no consecutive registry has evaluated the usefulness of different adenosine diphosphate-based platelet function tests to predict outcome in unselected patients. Hence, our objective was to determine the feasibility of MEA and VASP-P for clinical routine and whether low-response to clopidogrel as determined by MEA and/or the VASP-P assays predicts MACE in a "real-life" population undergoing coronary stenting. Threehundred consecutive patients were included in this prospective registry. Blood was sampled 6-24 hours after stenting to measure MEA and VASP-P. The use of glycoprotein-IIb/IIIa-blockers limited MEA to 196 measurements. Concerning the VASP-P assay, 300 measurements were achieved. Receiver Operating Characteristics (ROC)-curves of sensitiv- ity and specificity estimates for MACE were plotted for VASP-P assay. The area under the ROC-curve was 0.683 (p=0.014) for the platelet reactivity index (PRI) calculated from median fluorescence intensities (FI) with an optimal cut-off at 60.2% PRI. Patients above 60.2% had a significantly increased risk for MACE at six months follow-up (p=0.007). Estimating the cut-offs for the PRI from mean FI (52%) or from geometric mean FI (56.6%) led to clinically relevant differences. VASP-P assay is feasible for clinical routine to measure clopidogrel effects and to predict post-procedural MACE in unselected patients. With regard to differing cut-offs, exact standardisation of the VASP-P assay is mandatory. The use of GP-IIb/IIIa-blockers prevents MEA testing and limits its usability in unselected patients.
Background: Increased platelet turnover and high platelet reactivity are associated with short-term major adverse cardiovascular events (MACE) after percutaneous coronary intervention (PCI) for acute coronary syndrome (ACS) or stable coronary artery disease (SCAD). We investigated the impact of platelet turnover on long-term MACE. Methods: Consecutive patients presenting with ACS or SCAD undergoing PCI between 2009 and 2010 were included. All patients received clopidogrel and aspirin as dual antithrombotic therapy regimen. Multivariable Cox proportional hazard models were applied to assess the prognostic impact of platelet turnover (reticulated platelet count [RPC], mean platelet volume [MPV]) and function on long-term MACE, a composite of cardiovascular death, nonfatal myocardial infarction and nonfatal stroke. Results: In total, 477 patients were eligible. Mean age was 64.3 ± 12.7 years, 68.8% were male. Median follow-up was 5.8 (IQR 4.2-6.5) years. Median RPC was 7.6 (IQR 5.6-10.4) g/L and median MPV was 10.7 (IQR 10.1-11.3) fL. In univariable analysis, RPC was associated with MACE, both as continuous (HR 1.064 [95%CI 1.021-1.111]; P = .006) and dichotomized (HR 1.693 [95%CI 1.156-2.481]; P = .006) variable. After adjustment, continuous RPC (HR 1.055 [95%CI 1.012-1.099]; P = .010) and dichotomized RPC (HR 1.716 [95%CI 1.152-2.559]; P = .007) remained significantly associated with MACE. Neither MPV nor platelet function testing was associated with long-term adverse outcome.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.