Using the oscillometric method, indirect mean arterial pressure was measured in 14 pentobarbital-anesthetized dogs (8-24 kg) with mean arterial pressure ranging from 23 to 160 mmHg. The effect of cuff size, in relation to forelimb circumference was investigated. Indirect mean arterial pressure agreed with direct mean arterial pressure when the cuff width was about 40% of the forelimb circumference.
It is sometimes difficult to obtain uninterrupted data sets that are long enough to perform nonlinear analysis, especially in pathological populations. It is currently unclear as to how many data points are needed for reliable entropy analysis. The aims of this study were to determine the effect of changing parameter values of m, r, and N on entropy calculations for long gait data sets using two different modes of walking (i.e., overground versus treadmill). Fourteen young adults walked overground and on a treadmill at their preferred walking speed for one-hour while step time was collected via heel switches. Approximate (ApEn) and sample entropy (SampEn) were calculated using multiple parameter combinations of m, N, and r. Further, r was tested under two cases r*standard deviation and r constant. ApEn differed depending on the combination of r, m, and N. ApEn demonstrated relative consistency except when m=2 and the smallest r values used (rSD=0.015*SD, 0.20*SD; rConstant=0 and 0.003). For SampEn, as r increased, SampEn decreased. When r was constant, SampEn demonstrated excellent relative consistency for all combinations of r, m, and N. When r constant was used, overground walking was more regular than treadmill. However, treadmill walking was found to be more regular when using rSD for both ApEn and SampEn. For greatest relative consistency of step time data, it was best to use a constant r value and SampEn. When using entropy, several r values must be examined and reported to ensure that results are not an artifact of parameter choice.
Sample entropy (SE) has relative consistency using biologically-derived, discrete data >500 data points. For certain populations, collecting this quantity is not feasible and continuous data has been used. The effect of using continuous versus discrete data on SE is unknown, nor are the relative effects of sampling rate and input parameters m (comparison vector length) and r (tolerance). Eleven subjects walked for 10-minutes and continuous joint angles (480 Hz) were calculated for each lower-extremity joint. Data were downsampled (240, 120, 60 Hz) and discrete range-of-motion was calculated. SE was quantified for angles and range-of-motion at all sampling rates and multiple combinations of parameters. A differential relationship between joints was observed between range-of-motion and joint angles. Range-of-motion SE showed no difference; whereas, joint angle SE significantly decreased from ankle to knee to hip. To confirm findings from biological data, continuous signals with manipulations to frequency, amplitude, and both were generated and underwent similar analysis to the biological data. In general, changes to m, r, and sampling rate had a greater effect on continuous compared to discrete data. Discrete data was robust to sampling rate and m. It is recommended that different data types not be compared and discrete data be used for SE.
The aim of this investigation was to compare and contrast the use of cross sample entropy (xSE) and cross recurrence quantification analysis (cRQA) measures for the assessment of coupling of rhythmical patterns. Measures were assessed using simulated signals with regular, chaotic, and random fluctuations in frequency, amplitude, and a combination of both. Biological data were studied as models of normal and abnormal locomotor-respiratory coupling. Nine signal types were generated for seven frequency ratios. Fifteen patients with COPD (abnormal coupling) and twenty-one healthy controls (normal coupling) walked on a treadmill at three speeds while breathing and walking were recorded. xSE and the cRQA measures of percent determinism, maximum line, mean line, and entropy were quantified for both the simulated and experimental data. In the simulated data, xSE, percent determinism, and entropy were influenced by the frequency manipulation. The 1 : 1 frequency ratio was different than other frequency ratios for almost all measures and/or manipulations. The patients with COPD used a 2 : 3 ratio more often and xSE, percent determinism, maximum line, mean line, and cRQA entropy were able to discriminate between the groups. Analysis of the effects of walking speed indicated that all measures were able to discriminate between speeds.
The purpose of the study was to compare the effects of a feedback-controlled treadmill (FeedbackTM) to a traditional fixed-speed treadmill (FixedTM) on spatiotemporal gait means, variability, and dynamics. The study also examined inter-session reliability when using the FeedbackTM. Ten young adults walked on the FeedbackTM for a 5-minute familiarization followed by a 16-minute experimental trial. They returned within one week and completed a 5minute familiarization followed by a 16-minute experimental trial each for FeedbackTM and FixedTM conditions. Mean walking speed and step time, length, width, and speed means and coefficient of variation were calculated from all experimental conditions. Step time, length, width, and speed gait dynamics were analyzed using detrended fluctuation analysis. Mean differences between experimental trials were determined using ANOVAs and reliability between FeedbackTM sessions was determined by intraclass correlation coefficient. No difference was found in mean walking speed nor spatiotemporal variables, with the exception of step width, between the experimental trials. All mean spatiotemporal variables demonstrated good to excellent reliability between sessions, while coefficient of variation was not reliable. Gait dynamics of step time, length, width, and speed were significantly more persistent during the FeedbackTM condition compared to FixedTM, especially step speed. However, gait dynamics demonstrated fair to poor reliability between FeedbackTM sessions. When walking on the FeedbackTM, users maintain a consistent set point, yet the gait dynamics around the mean are different when compared to walking on a FixedTM. In addition, spatiotemporal gait dynamics and variability may not be consistent across separate days when using the FeedbackTM.
Sample entropy (SaEn) has been used to assess the regularity of lower limb joint angles during walking. However, changing sampling frequency and the number of included strides can potentially affect the outcome. The present study investigated the effect of sample frequency and the number of included strides on the calculations of SaEn in joint angle signals recorded during treadmill walking. Eleven subjects walked at their preferred walking speed for 10 minutes, and SaEn was calculated on sagittal plane hip, knee and ankle angle signals extracted from 50, 100, 200, 300 and 400 strides at sampling frequencies of 60, 120, 240 and 480Hz. Increase in sampling frequency decreased the SaEn significantly for the three joints. The number of included strides had no effect on the SaEn calculated on the hip joint angle and only limited effect on the SaEn calculated on the knee and ankle joint signals. The present study suggests that the number of data points within each stride to a greater extent determines the size of the SaEn compared to the number of strides and emphasizes the use of a fixed number of data points within each stride when applying SaEn to lower limb joint angles during walking.
The present study aimed at identifying a suitable multiscale entropy (MSE) algorithm for assessment of complexity in a stride-to-stride time interval time series. Five different algorithms were included (the original MSE, refine composite multiscale entropy (RCMSE), multiscale fuzzy entropy, generalized multiscale entropy and intrinsic mode entropy) and applied to twenty iterations of white noise, pink noise, or a sine wave with added white noise. Based on their ability to differentiate the level of complexity in the three different generated signal types, and their sensitivity and parameter consistency, MSE and RCMSE were deemed most appropriate. These two algorithms were applied to stride-to-stride time interval time series recorded from fourteen healthy subjects during one hour of overground and treadmill walking. In general, acceptable sensitivity and good parameter consistency were observed for both algorithms; however, they were not able to differentiate the complexity of the stride-to-stride time interval time series between the two walking conditions. Thus, the present study recommends the use of either MSE or RCMSE for quantification of complexity in stride-to-stride time interval time series.
The reliability of the treadmill belt speed using a feedback-controlled treadmill algorithm was analyzed in this study. Using biomechanical factors of the participant’s walking behavior, an estimated walking speed was calculated and used to adjust the speed of the treadmill. Our proposed algorithm expands on the current hypotheses of feedback-controlled treadmill algorithms and is presented below. Nine healthy, young adults walked on a treadmill controlled by the algorithm for three trials over two days. Each participant walked on the feedback-controlled treadmill for one 16-minute and one five-minute trial during day one and one 16-minute trial during day two. Mean, standard deviation, interclass correlation coefficient (ICC), and standard error of measurement (SEM) were analyzed on the treadmill belt speed mean, standard deviation, and coefficient of variation. There were significantly high ICC for mean treadmill speed within- and between-days. Treadmill speed standard deviation and coefficient of variation were significantly reliable within-day. These results suggest the algorithm will reliably produce the same treadmill belt speed mean, but may only produce a similar treadmill belt speed standard deviation and coefficient of variation if the trials are performed in the same day. A feedback-controlled treadmill algorithm that accounts for the user’s behavior provides a greater level of control and minimizes any possible constraints of walking on a conventional treadmill.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.