Elasto-optical refractive index modulation due to photoacoustic initial pressure transients produced significant reflection of a probe beam when the absorbing interface had an appreciable refractive index difference. This effect was harnessed in a new form of non-contact optical resolution photoacoustic microscopy called photoacoustic remote sensing microscopy. A non-interferometric system architecture with a low-coherence probe beam precludes detection of surface oscillations and other phase-modulation phenomenon. The probe beam was confocal with a scanned excitation beam to ensure detection of initial pressure-induced intensity reflections at the subsurface origin where pressures are largest. Phantom studies confirmed signal dependence on optical absorption, index contrast and excitation fluence. In vivo imaging of superficial microvasculature and melanoma tumors was demonstrated with ~2.7±0.5 μm lateral resolution.
In this Letter, the capability of label-free fiber-based optical-resolution photoacoustic microscopy is demonstrated. This real-time imaging system takes advantage of image-guide fibers and a unique fiber laser. The 800 μm image-guide consists of 30,000 individual single-mode fibers in a bundle and the diode-pumped, pulsed Ytterbium fiber laser is utilized to perform up to 600 kHz repetition rate. Phantom studies indicate 7 μm resolution. The proposed setup keeps many of the powerful properties of previous tabletop OR-PAM systems, but also offers a submillimeter probe footprint and high flexibility due to the nature of the image-guide. This system could have significant clinical impact for endoscopic applications where the thin fiber can be inserted into the body.
Optical-resolution photoacoustic microscopy (OR-PAM) is capable of achieving optical-absorption-contrast images with micron-scale spatial resolution. Previous OR-PAM systems have been frame-rate limited by mechanical scanning speeds and laser pulse repetition rate (PRR). We demonstrate OR-PAM imaging using a diode-pumped nanosecond-pulsed Ytterbium-doped 532-nm fiber laser with PRR up to 600 kHz. Combined with fast-scanning mirrors, our proposed system provides C-scan and 3D images with acquisition frame rate of 4 frames per second (fps) or higher, two orders of magnitude faster than previously published systems. High-contrast images of capillary-scale microvasculature in a live Swiss Webster mouse ear with ~6-µm optical lateral spatial resolution are demonstrated.
Abstract. While more than 90% of cancer deaths are due to metastases, our ability to detect circulating tumor cells (CTCs) is limited by low numbers of these cells in the blood and factors confounding specificity of detection. We propose a magnetic enrichment and detection technique for detecting CTCs with high specificity. We targeted both magnetic and surface-enhanced Raman scattering (SERS) nanoparticles to cancer cells. Only cells that are dual-labeled with both kinds of nanoparticles demonstrate an increasing SERS signal over time due to magnetic trapping.
In this paper a new generation of optical-resolution photoacoustic microscopy (OR-PAM) with a wide range of potential clinical applications is demonstrated. Using fast scanning mirrors, an image guide with 30,000 fiber pixels, a refocusing lens and a unique probe we managed to reduce the footprint of an OR-PAM system from a stationary table-top system to a portable, 4 cm by 6 cm, probe weighing ~500 g tethered to a scanning unit. The phantom studies show that the handheld optical-resolution photoacoustic microscope is able to image with ~7 μm resolution. For in vivo studies images of the microvasculature in a Swiss Webster mouse ear are shown. The compact, flexible nature of the proposed design and the small footprint of the apparatus increase the usability of OR-PAM for potential clinical applications such as in dermatology.
Abstract. Optical-resolution photoacoustic microscopy ͑OR-PAM͒ is a novel imaging technology for visualizing optically absorbing superficial structures in vivo with lateral spatial resolution determined by optical focusing rather than acoustic detection. Since scanning of the illumination spot is required, OR-PAM imaging speed is limited by both scanning speed and laser pulse repetition rate. Unfortunately, lasers with high repetition rates and suitable pulse durations and energies are not widely available and can be cost-prohibitive and bulky. We are developing compact, passively Q-switched fiber and microchip laser sources for this application. The properties of these lasers are discussed, and pulse repetition rates up to 100 kHz are demonstrated. OR-PAM imaging was conducted using a previously developed photoacoustic probe, which enabled flexible scanning of the focused output of the lasers. Phantom studies demonstrate the ability to image with lateral spatial resolution of 7±2 m with the microchip laser system and 15± 5 m with the fiber laser system. We believe that the high pulse repetition rates and the potentially compact and fiber-coupled nature of these lasers will prove important for clinical imaging applications where real-time imaging performance is essential.
Gene expression signatures of toxicity and clinical response benefit both safety assessment and clinical practice; however, difficulties in connecting signature genes with the predicted end points have limited their application. The Microarray Quality Control Consortium II (MAQCII) project generated 262 signatures for ten clinical and three toxicological end points from six gene expression data sets, an unprecedented collection of diverse signatures that has permitted a wide-ranging analysis on the nature of such predictive models. A comprehensive analysis of the genes of these signatures and their nonredundant unions using ontology enrichment, biological network building and interactome connectivity analyses demonstrated the link between gene signatures and the biological basis of their predictive power. Different signatures for a given end point were more similar at the level of biological properties and transcriptional control than at the gene level. Signatures tended to be enriched in function and pathway in an end point and model-specific manner, and showed a topological bias for incoming interactions. Importantly, the level of biological similarity between different signatures for a given end point correlated positively with the accuracy of the signature predictions. These findings will aid the understanding, and application of predictive genomic signatures, and support their broader application in predictive medicine.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.