BackgroundApproximately 30% of patients treated with cardiac resynchronization therapy (CRT) do not achieve favourable response. The purpose of the present study was to identify echocardiographic and clinical predictors of a positive response to CRT.MethodsThe study included 82 consecutive heart failure (HF) patients in New York Heart Association (NYHA) functional class III or IV with left bundle branch block (LBBB), QRS duration ≥ 120 ms and left ventricular ejection fraction (LVEF) ≤ 35%. Statistical analysis was performed using IBM SPSS statistical software (SPSS v.21.0 for Mac OS X). A p value < 0.05 was considered statistically significant.ResultsEchocardiographic response was established in 81.6% and clinical response was achieved in 82.9% of patients. Significant univariate predictors of favourable echocardiographic response after 12 months were smaller left ventricular end-diastolic diameter (LVEDD) (odds ratio [OR] 0.89; 95% confidence interval [CI] 0.82 - 0.97, p = 0.01), and smaller left ventricular end-systolic diameter (LVESD) (OR 0.91; 95% CI 0.85 - 0.98, p = 0.01). Lower uric acid concentration was associated with better echocardiographic response (OR 0.99; 95% CI 0.99 - 1.0, p = 0.01). Non-ischemic HF etiology (OR 4.89; 95% CI 1.39 - 17.15, p = 0.01) independently predicted positive clinical response. Multiple stepwise regression analysis demonstrated that LVEDD lower than 75 mm (OR 5.60; 95% confidence interval [CI] 1.36 - 18.61, p = 0.01) was the strongest independent predictor of favourable echocardiographic response.ConclusionsSmaller left ventricular end-diastolic and end-systolic diameters and lower serum uric acid concentration were associated with better response to CRT. Left ventricular end-diastolic diameter and non-ischemic heart failure etiology were the strongest independent predictors of positive response to CRT.
Idiopathic ventricular tachycardia is a rare condition, and there is a lack of clear guidelines for the necessity and indications for prophylactic antiarrhythmic or curative treatment.The aim of this study was to review the clinical picture of idiopathic ventricular tachycardia and evaluate the efficacy and safety of radiofrequency ablation therapy in children.Material and methods. The subjects of this study were 16 children with idiopathic ventricular tachycardia. The mean age at onset of idiopathic ventricular tachycardia was 12 years. All patients underwent electrophysiological examination. Nonfluoroscopic mapping technology (Carto TM ) was used in one case. Radiofrequency ablation was performed in all children (mean duration of follow-up was 46 months).Results. Six children with idiopathic ventricular tachycardia were free of symptoms. Palpitation was the only complain in four patients, and six patients presented with symptoms of circulatory disorder (the tendency of the higher rate of ventricular tachycardia and more premature contractions and episodes of ventricular tachycardia in one day were noticed in five of them). All children after radiofrequency ablation were alive, and only one complication (complete right bundle branch block) occurred. Success at last follow-up included five children with left and six with right idiopathic ventricular tachycardia.Conclusions. Catheter ablation seems a promising therapeutic option with the outlook possible of the idiopathic ventricular tachycardia in children. It is safe enough and should be considered as the therapy of choice even in children without of symptoms if they wish to live active social and physical life.
Eighty-two patients with ectopic atrial tachycardia (EAT) were subjected to radical closed heart surgery (without cardiopulmonary bypass). The age of the patients ranged from 1 to 51 years. Permanent EAT was present in 19 patients, incessant EAT in 14, and paroxysmal EAT in 49 patients. Preoperative electrophysiological study included computed analysis of the P wave vector. Ectopic foci were established in the right atrium in 34 patients, in the left atrium in 11, in the interatrial septum in 32, and extracardially in 5 patients. For ablation or isolation of the foci, the cryogenic technique was used in 74 patients, cryo- and laser techniques in 4, and the laser technique alone in 1 patient. In 3 patients resection of the atrial auricles including the ectopic focus was undertaken. In 4 patients complete AV block was induced and a cardiac pacemaker implanted. After primary surgery, favourable results were obtained in 71 patients. In 11 patients recurrences were observed; 8 of these patients underwent successful repeat surgery. In 3 patients medical treatment was effective. Finally, the follow-up results have been promising-79 patients (96.4%) (including 4 patients in whom a complete AV block was created) have become arrhythmia-free. When EAT is resistant to medical treatment, closed heart ablation of the ectopic focus has proved to be safe (no mortality or morbidity) and effective. It can therefore be recommended not only for the termination of EAT but also for the prevention of dilated cardiomyopathy.
Objectives. The aim of the study was to study some anatomic and electrophysiological features of the right atrium, related to the presence of atrial flutter. Materials and methods. A total 23 patients with type I atrial flutter and 22 patients without atrial flutter were studied. Right atrium size was assessed using echocardiography before intracardiac examination and radiofrequency ablation. Results. Effective refractory periods of coronary sinus, high right atrium, low right atrium were different comparing with the control group (P<0.05). A stimulus–response time between high right atrium and low right atrium positions in anterograde and retrograde ways, an impulse propagation speed along the lateral wall of the right atrium were statistically different comparing both groups (P<0.05). There was a significant correlation among effective refractory periods measured in different sites of the right atrium (r²=0.64, 0.44, 0.44, respectively). All measured effective refractory periods also correlated with stimulus–response time in anterograde way (P<0.05) and impulse propagation speed (P<0.05). Right atrium dimensions were significantly larger in atrial flutter group. There was no correlation between the right atrium dimensions and measured electrophysiological parameters in both groups.Conclusions. The presence of atrial flutter associates with diffuse alterations of the right atrium, but not the focal or single changes of refractoriness.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.