The resolution and quantitative accuracy of PET are highly influenced by the reconstruction method. Penalized-likelihood estimation algorithms allow for fully convergent iterative reconstruction, generating a higher image contrast than ordered-subsets expectation maximization (OSEM) while limiting noise. In this study, a type of penalized reconstruction known as block-sequential regularized expectation maximization (BSREM) was compared with time-of-flight OSEM (TOF OSEM). Various strengths of noise penalization factor β were tested along with various acquisition durations and transaxial fields of view (FOVs) with the aim of evaluating the performance and clinical use of BSREM for F-FDG PET/CT, both quantitatively and in a qualitative visual evaluation. Eleven clinical whole-body F-FDG PET/CT examinations acquired on a digital TOF PET/CT scanner were included. The data were reconstructed using BSREM with point-spread function recovery and β-factors of 133, 267, 400, and 533-and using TOF OSEM with point-spread function-for various acquisition times per bed position and various FOVs. Noise level, signal-to-noise ratio (SNR), signal-to-background ratio (SBR), and SUV were analyzed. A masked evaluation of visual image quality, rating several aspects, was performed by 2 nuclear medicine physicians to complement the analysis. The lowest levels of noise were reached with the highest β-factor, resulting in the highest SNR, which in turn resulted in the lowest SBR. A β-factor of 400 gave noise equivalent to TOF OSEM but produced a significant increase in SUV (11%), SNR (22%), and SBR (12%). BSREM with a β-factor of 533 at a decreased acquisition duration (2 min/bed position) was comparable to TOF OSEM at a full acquisition duration (3 min/bed position). Reconstructed FOV had an impact on BSREM outcome measures; SNR increased and SBR decreased when FOV was shifted from 70 to 50 cm. The evaluation of visual image quality resulted in similar scores for reconstructions, although a β-factor of 400 obtained the highest mean whereas a β-factor of 267 was ranked best in overall image quality, contrast, sharpness, and tumor detectability. In comparison with TOF OSEM, penalized BSREM reconstruction resulted in an increased tumor SUV and an improved SNR and SBR at a matched level of noise. BSREM allowed for a shorter acquisition than TOF OSEM, with equal image quality.
In idiopathic Parkinson disease and atypical parkinsonian disorders, central dopaminergic and overall brain functional activity are altered to different degrees, causing difficulties in achieving an unambiguous clinical diagnosis. A dual examination using 123 I-FP-CIT ( 123 I-N-ω-fluoropropyl-2β-carbomethoxy-3β-(4-iodophenyl)nortropane, or 123 I-ioflupane) SPECT and 18 F-FDG PET provides complementary information on dopamine transporter (DAT) availability and overall brain functional activity, respectively. Parametric images based on a single, dynamic 11 C-PE2I (N-(3-iodoprop-2E-enyl)-2β-carbomethoxy-3β-(4-methyl-phenyl)nortropane) scan potentially supply both DAT availability (nondisplaceable binding potential [BP ND ]) and relative cerebral blood flow (relative delivery [R 1 ]) at voxel level. This study aimed to evaluate the validity of 11 C-PE2I PET against the dualmodality approach using 123 I-FP-CIT SPECT and 18 F-FDG PET. Methods: Sixteen patients with parkinsonian disorders had a dual examination with 18 F-FDG PET and 123 I-FP-CIT SPECT following clinical routines and additionally an experimental 11 C-PE2I PET scan. Parametric BP ND and R 1 images were generated using receptor parametric mapping with the cerebellum as a reference. T1-weighted MR imaging was used for automated definition of volumes of interest (VOI). The DAT VOIs included the basal ganglia, whereas the overall brain functional activity was examined using VOIs across the brain. BP ND and R 1 values were compared with normalized 123 I-FP-CIT and 18 F-FDG uptake values, respectively, using Pearson correlations and regression analyses. In addition, 2 masked interpreters evaluated the images visually, in both the routine and the experimental datasets, for comparison of patient diagnoses. Results: Parametric 11 C-PE2I BP ND and R 1 images showed high consistency with 123 I-FP-CIT SPECT and 18 F-FDG PET images. Correlations between 11 C-PE2I BP ND and 123 I-FP-CIT uptake ratios were 0.97 and 0.76 in the putamen and caudate nucleus, respectively. Regional 11 C-PE2I R 1 values were moderately to highly correlated with normalized 18 F-FDG values (range, 0.61-0.94). Visual assessment of DAT availability showed a high consistency between 11 C-PE2I BP ND and 123 I-FP-CIT images, whereas the consistency was somewhat lower for appraisal of overall brain functional activity using 123 I-FP-CIT and 18 F-FDG images. Substantial differences were found between clinical diagnosis and both neuroimaging diagnoses. Conclusion: A single, dynamic 11 C-PE2I PET investigation is a powerful alternative to a dual examination with 123 I-FP-CIT SPECT and 18 F-FDG PET for differential diagnosis of parkinsonian disorders. A large-scale patient study is, however, needed to further investigate distinct pathologic patterns in overall brain functional activity for various parkinsonian disorders.
The presence and termination of early seizure manifestations may be favourable prognostic factors in patients with low-grade gliomas.
Twelve children, all boys, aged 4 to 7 years, with a diagnosis of autistic disorder and low concentrations of spinal 6R-l-erythro-5,6,7,8-tetrahydrobiopterin (tetrahydrobiopterin) were selected to participate in a double-blind, randomized, placebo-controlled, crossover study. The children received a daily dose of 3 mg tetrahydrobiopterin per kilogram during 6 months alternating with placebo. Treatment-induced effects were assessed with the Childhood Autism Rating Scale every third month. The results showed small nonsignificant changes in the total scores of Childhood Autism Rating Scale after 3- and 6-month treatment. Post hoc analysis looking at the 3 core symptoms of autism, that is, social interaction, communication, and stereotyped behaviors, revealed a significant improvement of the social interaction score after 6 months of active treatment. In addition, a high positive correlation was found between response of the social interaction score and IQ. The results indicate a possible effect of tetrahydrobiopterin treatment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.