2018
DOI: 10.2967/jnumed.117.200790
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Penalized-Likelihood Estimation Reconstruction on a Digital Time-of-Flight PET/CT Scanner for 18F-FDG Whole-Body Examinations

Abstract: The resolution and quantitative accuracy of PET are highly influenced by the reconstruction method. Penalized-likelihood estimation algorithms allow for fully convergent iterative reconstruction, generating a higher image contrast than ordered-subsets expectation maximization (OSEM) while limiting noise. In this study, a type of penalized reconstruction known as block-sequential regularized expectation maximization (BSREM) was compared with time-of-flight OSEM (TOF OSEM). Various strengths of noise penalizatio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

12
91
2
2

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 77 publications
(107 citation statements)
references
References 17 publications
12
91
2
2
Order By: Relevance
“…We showed that SUV recoveries achieved using BPL with β-values of 450 to 700 always exceed those achieved by OSEM with or without PSF. In support of our findings others already showed that SUV recoveries achieved when optimizing OSEM+PSF do never reach the same levels as achieved using BPL [27]. With phantom studies with spheres sized 4-37 mm, we demonstrated improved small lesion detectability for spherical lesions down to 5 mm in diameter due to high levels of convergence achieved with BPL, which extends the findings of an earlier phantom study with spheres sized 10-37 mm [14].…”
Section: Discussionsupporting
confidence: 90%
See 1 more Smart Citation
“…We showed that SUV recoveries achieved using BPL with β-values of 450 to 700 always exceed those achieved by OSEM with or without PSF. In support of our findings others already showed that SUV recoveries achieved when optimizing OSEM+PSF do never reach the same levels as achieved using BPL [27]. With phantom studies with spheres sized 4-37 mm, we demonstrated improved small lesion detectability for spherical lesions down to 5 mm in diameter due to high levels of convergence achieved with BPL, which extends the findings of an earlier phantom study with spheres sized 10-37 mm [14].…”
Section: Discussionsupporting
confidence: 90%
“…However, this comes with somewhat less small lesion detectability and lower SUV recovery values (Figs 1-2). Other studies showed that lowering β-values down to 100 has a positive effect on contrast recovery though with higher noise levels, in general they conclude that for 18 F-FDG whole body scans a β-value of 400-500 would be optimal [14,16,27]. We showed that SUV recoveries achieved using BPL with β-values of 450 to 700 always exceed those achieved by OSEM with or without PSF.…”
Section: Discussionmentioning
confidence: 51%
“…The clinical study showed that the SUV mean was signi cantly higher using SiPM-PET than PMT-PET and did not correlate with the delay of the time from the injection (38). The superior spatial resolution by SiPM-PET not only improved image contrast but also increased the SUV mean in the cortex (39). The higher Z-scores determined using SiPM-PET was affected by higher SUV mean .…”
Section: Fovmentioning
confidence: 97%
“…the positive penalization parameter, is named the β factor. Q.Clear has been shown to provide better quantitation accuracy and image quality than OSEM in both phantom and clinical 18 F-FDG studies [5][6][7][8]. An optimal penalization parameter of 400 has been de ned for 18 F-FDG examinations [5,7].…”
Section: Introductionmentioning
confidence: 99%