The effect of a mixture of vitamins in modifying the efficacy of commonly used drugs in the treatment of human melanoma has not been studied. Vitamin C and d-alpha-tocopheryl succinate (alpha-TS) alone reduced the growth of human melanoma (SK-30) cells in culture, whereas beta-carotene (BC), 13-cis-retinoic acid (RA), or sodium selenite alone was ineffective. RA caused morphological changes, as evidenced by flattening of cells and formation of short cytoplasmic processes. A mixture of four vitamins (vitamin C, BC, alpha-TS, and RA) was more effective in reducing growth of human melanoma cells than a mixture of three vitamins. The growth-inhibitory effect of cis-platin, decarbazine, tamoxifen, and recombinant interferon-alpha 2b was enhanced by vitamin C alone, a mixture of three vitamins (BC, alpha-TS, and RA), and a mixture of four vitamins (vitamin C, BC, alpha-TS, and RA) that contained 50 micrograms/ml of vitamin C. These data show that a mixture of three or four vitamins can enhance the growth-inhibitory effect of currently used chemotherapeutic agents on human melanoma cells.
Background:Robotic-arm-assisted unicompartmental knee arthroplasty (UKA) has been shown to result in high short- and mid-term survivorship. However, it is not known whether these outcomes are maintained at long-term follow-up. This study aimed to evaluate long-term implant survivorship, modes of failure, and patient satisfaction following robotic-arm-assisted medial UKA.Methods:A prospective multicenter study of 474 consecutive patients (531 knees) undergoing robotic-arm-assisted medial UKA was conducted. A cemented, fixed-bearing system with a metal-backed onlay tibial implant was used in all cases. Patients were contacted at 10-year follow-up to determine implant survivorship and satisfaction. Survival was analyzed using Kaplan-Meier models.Results:Data were analyzed for 366 patients (411 knees) with a mean follow-up of 10.2 ± 0.4 years. A total of 29 revisions were reported, corresponding to a 10-year survivorship of 91.7% (95% confidence interval, 88.8% to 94.6%). Of all revisions, 26 UKAs were revised to total knee arthroplasty. Unexplained pain and aseptic loosening were the most commonly reported modes of failure, accounting for 38% and 35% of revisions, respectively. Of patients without revision, 91% were either satisfied or very satisfied with their overall knee function.Conclusions:This prospective multicenter study found high 10-year survivorship and patient satisfaction following robotic-arm-assisted medial UKA. Pain and fixation failure remained common causes for revision following cemented fixed-bearing medial UKA, despite the use of a robotic-arm-assisted technique. Prospective comparative studies are needed to assess the clinical value of robotic assistance over conventional techniques in UKA.Level of Evidence:Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.