Polymerase chain reaction (PCR)-based STR DNA typing systems are used extensively in the field of human identification. Under optimal PCR conditions, the amplicon yield from both alleles of an STR locus is expected to be approximately equivalent. However, it is reasonable to expect that rare genomic sequence polymorphisms will co-localize with well-designed primer sets and induce allele imbalance or "dropouts". Two samples were identified in the course of genotyping thousands of individuals with AmpF/STR R Profiler Plus TM that showed strong disparity in amplitude peak height of heterozygous peaks at the loci vWA and FGA. These samples were reamplified at reduced annealing temperature in an attempt to balance the peak heights. Nucleotide sequencing documented polymorphisms at the PCR primer binding sites of the affected alleles. The results indicate that reducing the annealing temperature to improve primer-binding efficiency at the mismatch and employing an alternative multiplex enhanced the data from both samples. Reducing annealing temperatures could provide a simple general solution to improving data quality for samples where polymorphisms are suspected to cause allele imbalance. Finally, we report on additional polymorphisms surrounding the vWA locus in a genetically diverse population.
A population study of Caucasians residing in Maine was conducted using the AmpF1STR™ Profiler PCR Amplification Kit and the AmpF1STR™ Profiler Plus PCR Amplification Kit (Applied Biosystems Division (ABD) of Perkin Elmer, Foster City, CA). The kits contain the reagents necessary to amplify 12 different STR loci and the gender marker Amelogenin using two multiplex PCR, each containing nine STR loci. Thus, there is an overlap of six STR loci. The 12 STR loci are TH01, TPOX, CSF1PO, D3S1358, vWA, FGA, D8S1179, D21S11, D18S51, D5S818, D13S317, and D7S820. These loci represent 12 of the 13 core loci selected by the CODIS STR standardization project. Dye-labeled amplification products were separated and detected using the capillary electrophoresis instrument ABI Prism™ 310 Genetic Analyzer. Allele frequencies were determined for the 12 STR loci. Statistical analysis of the data included Hardy-Weinburg equilibrium (HWE) analysis, pairwise independence testing, power of discrimination (PD), and probability of exclusion (PE).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.