Antimicrobial resistance (AMR) is a serious threat to global public health, but obtaining representative data on AMR for healthy human populations is difficult. Here, we use metagenomic analysis of untreated sewage to characterize the bacterial resistome from 79 sites in 60 countries. We find systematic differences in abundance and diversity of AMR genes between Europe/North-America/Oceania and Africa/Asia/South-America. Antimicrobial use data and bacterial taxonomy only explains a minor part of the AMR variation that we observe. We find no evidence for cross-selection between antimicrobial classes, or for effect of air travel between sites. However, AMR gene abundance strongly correlates with socio-economic, health and environmental factors, which we use to predict AMR gene abundances in all countries in the world. Our findings suggest that global AMR gene diversity and abundance vary by region, and that improving sanitation and health could potentially limit the global burden of AMR. We propose metagenomic analysis of sewage as an ethically acceptable and economically feasible approach for continuous global surveillance and prediction of AMR.
The use of beta-agonists as growth promoters in cattle breeding is forbidden in many countries for reasons of fair trade and consumer protection. In recent years the use of liquid chromatography (LC) tandem mass spectrometry (MS/MS) has been shown to be the method of choice for the control of beta-agonists. In this study an LC-MS/MS multiresidue analysis method is presented for trace analysis of 22 beta-agonists. A truly generic concept has been designed based on mixed-mode solid-phase extraction and positive electrospray ionisation LC-MS/MS operated in the multiple reaction monitoring mode. This method allows application to a wide variety of sample matrices such as urine, feed and hair, following minor modifications to the analysis procedure only. The method features fit-for-purpose sensitivity in urine as shown by CCalpha and CCbeta values of less than 0.2 and less than 0.5 microg/l respectively, for all beta-agonists studied (terbutaline and reproterol, less than 0.3 and less than 1.0 respectively). Similar but semiquantitative application to feed and hair showed CCbeta values of less than 10.0 and less than 5.0 microg/kg, respectively. A further simplification and improvement is demonstrated using Ultra Performance LC (UPLC) and fast-switching MS/MS. The successful validation of this method following the latest EU requirements and its application to real samples demonstrate that a new versatile tool has been achieved for veterinary control of beta-agonists.
There is a strong need for the development of relatively cheap and rapid bioassays for the determination of dioxins and related compounds in food. A newly developed CALUX (Chemical-Activated LUciferase gene eXpression) bioassay was tested for its possible use to determine low levels of dioxins in bovine milk. Data show that this mammalian cell-based test is very sensitive for 2,3,7,8-substituted dioxins and related PCBs, thereby reflecting the relative potencies of these compounds in comparison to TCDD (TEF-values). The limit of detection was about 50 fg of TCDD. Furthermore, the response obtained with a mixture of dioxins was additive, in accordance with the TEF-principle. Milk fat was isolated by centrifugation followed by clean-up of the fat with n-pentane, removal of the fat on a 33% H2SO4 silica column, and determination of Ah receptor agonist activity with the CALUX-bioassay. An equivalent of 67 mg fat was tested per experimental unit, resulting in a limit of quantification around 1 pg i-TEQ/g fat. To investigate the performance of the method, butter fat was cleaned and spiked with a mixture of 17 different 2,3,7,8-substituted PCDD and PCDF congeners at 1, 3, 6, 9, 12 and 15 pg TEQ/g fat, as confirmed by GC/MS. In this concentration range, the method showed a recovery of TEQs around 67% (58-87%). The reproducibility, determined in three independent series showed a CV varying between 4% and 54%, with the exception of the sample spiked at 1 pg i-TEQ (CV 97%). The repeatability determined with the sample spiked at 6 pg i-TEQ/g showed a CV of 10%. Testing of 22 bovine milk samples, taken at different sites in The Netherlands, in the CALUX-assay showed combined dioxin and dioxin-like PCB levels equivalent to 1.6 pg TCDD/g fat (range 0.2-4.6). GC/MS analysis of these samples revealed an average level of 1.7 pg i-TEQ/g fat, varying between 0.5 and 4.7 pg i-TEQ/g fat. All five samples showing a GC/MS determined dioxin content of more than 2 pg i-TEQ/g fat gave a response in the CALUX-assay corresponding to more than 2 pg TCDD/g fat. These data clearly show that the CALUX-bioassay is a promising method for the rapid and low cost screening of dioxins in bovine milk.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.