Due to the unexpected findings of the banned antibiotic chloramphenicol in products of animal origin, feed, and straw, the hypothesis was studied that the drug is naturally present in soil, through production by soil bacteria, and subsequently can be transferred to crops. First, the stability of chloramphenicol in soil was studied. The fate of chloramphenicol highly depends on soil type and showed a half-life of approximately one day in nonsterile topsoil. It was found to be more stable in subsoil and sterile soils. Second, the production of chloramphenicol in soil was studied, and it was confirmed that Streptomyces venezuelae can produce chloramphenicol at appreciable amounts in nonsterile soil. Third, a transfer study was carried out using wheat and maize grown on three different soils that were weekly exposed to aqueous chloramphenicol solutions at different levels. Chloramphenicol was taken up by crops as determined by chiral liquid chromatography coupled to tandem mass spectrometric analysis, and the levels in crops were found to be bioavailability related. It was concluded that chloramphenicol residues can occur naturally in crops as a result of the production of chloramphenicol by soil bacteria in their natural environment and subsequent uptake by crops.
A liquid chromatography–tandem mass spectrometry method for the analysis of seven antiviral drugs, zanamivir, ribavirin, oseltamivir, oseltamivir carboxylate, amantadine, rimantadine and arbidol, in poultry muscle is reported. The antiviral drugs were extracted from the homogenized poultry muscle sample using methanol. The extract was purified using tandem solid-phase extraction combining a cation exchange cartridge and a phenylboronic acid cartridge. To prevent excessive matrix effects, the analytes were separated from the matrix constituents using a column-switch liquid chromatography system combining a reversed-phase and a Hypercarb analytical column. Detection was carried out using tandem mass spectrometry. The method was fully validated according to 2002/657/EC [1] and proved to be adequate for quantification and confirmation of zanamivir and ribavirin at 10 μg kg−1, oseltamivir, oseltamivir carboxylate, amantadine and rimantadine at levels below 1.0 μg kg−1 and for qualitative confirmatory analysis of arbidol at levels below 1 μg kg−1.Electronic supplementary materialThe online version of this article (doi:10.1007/s00216-011-5581-3) contains supplementary material, which is available to authorized users.
A comprehensive method for the quantitative residue analysis of trace levels of 22 ß-lactam antibiotics, including penicillins, cephalosporins, and carbapenems, in poultry muscle by liquid chromatography in combination with tandem mass spectrometric detection is reported. The samples analyzed for ß-lactam residues are hydrolyzed using piperidine in order to improve compound stability and to include the total residue content of the cephalosporin ceftifour. The reaction procedure was optimized using a full experimental design. Following detailed isotope labeling, tandem mass spectrometry studies and exact mass measurements using high-resolution mass spectrometry reaction schemes could be proposed for all ß-lactams studied. The main reaction occurring is the hydrolysis of the ß-lactam ring under formation of the piperidine substituted amide. For some ß-lactams, multiple isobaric hydrolysis reaction products are obtained, in accordance with expectations, but this did not hamper quantitative analysis. The final method was fully validated as a quantitative confirmatory residue analysis method according to Commission Decision 2002/657/EC and showed satisfactory quantitative performance for all compounds with trueness between 80 and 110% and within-laboratory reproducibility below 22% at target level, except for biapenem. For biapenem, the method proved to be suitable for qualitative analysis only.
Abstract. Selectivity of the confirmation of identity in liquid chromatography (tandem) mass spectrometry using Q-Orbitrap instrumentation was assessed using different acquisition modes based on a representative experimental data set constructed from 108 samples, including six different matrix extracts and containing over 100 analytes each. Single stage full scan, all ion fragmentation, and product ion scanning were applied. By generating reconstructed ion chromatograms using unit mass window in targeted MS 2 , selected reaction monitoring (SRM), regularly applied using triplequadrupole instruments, was mimicked. This facilitated the comparison of single stage full scan, all ion fragmentation, (mimicked) SRM, and product ion scanning applying a mass window down to 1 ppm. Single factor Analysis of Variance was carried out on the variance (s 2 ) of the mass error to determine which factors and interactions are significant parameters with respect to selectivity. We conclude that selectivity is related to the target compound (mainly the mass defect), the matrix, sample clean-up, concentration, and mass resolution. Selectivity of the different instrumental configurations was quantified by counting the number of interfering peaks observed in the chromatograms. We conclude that precursor ion selection significantly contributes to selectivity: monitoring of a single product ion at high mass accuracy with a 1 Da precursor ion window proved to be equally selective or better to monitoring two transition products in mimicked SRM. In contrast, monitoring a single fragment in all ion fragmentation mode results in significantly lower selectivity versus mimicked SRM. After a thorough interlaboratory evaluation study, the results of this study can be used for a critical reassessment of the current identification points system and contribute to the next generation of evidence-based and robust performance criteria in residue analysis and sports doping.
Besides the identification point system to assure adequate set-up of instrumentation, European Commission Decision 2002/657/ EC includes performance criteria regarding relative ion abundances in mass spectrometry and chromatographic retention time. In confirmatory analysis, the relative abundance of two product ions, acquired in selected reaction monitoring mode, the ion ratio should be within certain ranges for confirmation of the identity of a substance. The acceptable tolerance of the ion ratio varies with the relative abundance of the two product ions and for retention time, CD 2002/657/EC allows a tolerance of 5%. Because of rapid technical advances in analytical instruments and new approaches applied in the field of contaminant testing in food products (multi-compound and multi-class methods) a critical assessment of these criteria is justified. In this study a large number of representative, though challenging sample extracts were prepared, including muscle, urine, milk and liver, spiked with 100 registered and banned veterinary drugs at levels ranging from 0.5 to 100 μg/kg. These extracts were analysed using SRM mode using different chromatographic conditions and mass spectrometers from different vendors. In the initial study, robust data was collected using four different instrumental set-ups. Based on a unique and highly relevant data set, consisting of over 39 000 data points, the ion ratio and retention time criteria for applicability in confirmatory analysis were assessed. The outcomes were verified based on a collaborative trial including laboratories from all over the world. It was concluded that the ion ratio deviation is not related to the value of the ion ratio, but rather to the intensity of the lowest product ion. Therefore a fixed ion ratio deviation tolerance of 50% (relative) is proposed, which also is applicable for compounds present at sub-ppb levels or having poor ionisation efficiency. Furthermore, it was observed that retention time shifts, when using gradient elution, as is common practice nowadays, are mainly observed for early eluting compounds. Therefore a maximum retention time deviation of 0.2 min (absolute) is proposed. These findings should serve as input for discussions on the revision of currently applied criteria and the establishment of a new, globally accepted, criterion document for confirmatory analysis.
A non-targeted workflow is reported for the isolation and identification of antimicrobial active compounds using bioassay-directed screening and LC coupled to high-resolution MS. Suspect samples are extracted using a generic protocol and fractionated using two different LC conditions (A and B). The behaviour of the bioactive compound under these different conditions yields information about the physicochemical properties of the compound and introduces variations in co-eluting compounds in the fractions, which is essential for peak picking and identification. The fractions containing the active compound(s) obtained with conditions A and B are selected using a microbiological effect-based bioassay. The selected bioactive fractions from A and B are analysed using LC combined with high-resolution MS. Selection of relevant signals is automatically carried out by selecting all signals present in both bioactive fractions A and B, yielding tremendous data reduction. The method was assessed using two spiked feed samples and subsequently applied to two feed samples containing an unidentified compound showing microbial growth inhibition. In all cases, the identity of the compound causing microbiological inhibition was successfully confirmed. ARTICLE HISTORY
Monitoring strategies for veterinary drugs in products of animal origin are shifting towards a more risk-based approach. Such strategies not only target a limited number of predefined .substances but also facilitate detection of unexpected substances. By combining the use of archive matrices such as feather meal with suspect-screening methods, early detection of new hazards in the food and feed industry can be achieved. Effective application of such strategies is hampered by complex data interpretation and therefore, targeted data analysis is commonly applied. In this study, the performance of a suspect-screening data processing workflow using a suspect list or the online spectral database mzCloud TM was explored to facilitate detection of veterinary drugs in archive matrices. Data evaluation parameters specifically investigated for application of a suspect list were mass tolerance and the addition or omission of retention times. Application of a mass tolerance of 1.5 ppm leads to an increase in the number of false positives, as does omission of retention times in the suspect list. Different acquisition modes yielding different qualities of MS2 data were studied and proved to be a critical factor, where data-dependent acquisition is preferred when matching to the mzCloud TM database. Using this approach, it is possible to search for compounds on a dedicated suspect list based on the exact mass and retention times and, at the same time, detect unexpected compounds without a priori information. A pilot study was conducted and fourteen different antibiotics were detected (and confirmed by MS/MS). Three of these antibiotics were not included in the suspect list. The optimised suspect-screening method proved to be fit for the purpose of finding veterinary drugs in feather meal, which are not in the scope of the current monitoring methods and therefore, it gives added value in the perspective of a risk-based monitoring.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.