Although this study was limited because it did not consider all risk factors, categorical chewing number was related independently to body weight increments of more than 10 kg from 20 years of age.
Background Head elevation can restore airway patency during anesthesia, although its effect may be offset by concomitant bite opening or accidental neck flexion. The aim of this study is to examine the effect of head elevation on the passive upper airway collapsibility during propofol anesthesia. Method Twenty male subjects were studied, randomized to one of two experimental groups: Fixed-jaw or Free-jaw. Propofol infusion was used for induction and to maintain blood concentration constant at a target level between 1.5 and 2.0 μg/ml. Nasal mask pressure (PN) was intermittently reduced to evaluate the upper airway collapsibility (passive PCRIT) and upstream resistance (RUS) at each level of head elevation (0, 3, 6, & 9 cm). We measured the Frankfort plane (head flexion) and the mandible plane (jaw opening) angles at each level of head elevation. Analysis of variance was used to determine effect of head elevation on PCRIT, head flexion and jaw opening within each group. Results In both groups the Frankfort plane and mandible plane angles increased as with head elevation (P < 0.05), although the mandible plane angle was lower in the Free-jaw group (i.e., increased jaw opening). In the Fixed-jaw group, head elevation decreased upper airway collapsibility (PCRIT ~ −7 cmH2O at greater than 6 cm elevation) compared to the baseline position (PCRIT ~ −3 cmH2O at 0 cm elevation; P < 0.05). Conclusion We demonstrate that elevating the head position by 6 cm while ensuring mouth closure (centric occlusion) produces substantial decreases in upper airway collapsibility and maintains upper airway patency during anesthesia.
Neurological conditions, such as stroke, can leave the affected individual with hand motor impairment despite intensive treatments. Novel technologies, such as brain-computer interface (BCI), may be able to restore or augment impaired motor behaviors by engaging relevant cortical areas. Here, we developed and tested an electroencephalogram (EEG) based BCI system for control of hand orthosis. An able-bodied subject performed contralateral hand grasping to achieve continuous online control of the hand orthosis, suggesting that the integration of a noninvasive BCI with a hand orthosis is feasible. The adoption of this technology to stroke survivors may provide a novel neurorehabilitation therapy for hand motor impairment in this population.
Stroke survivors are typically affected by hand motor impairment. Despite intensive rehabilitation and spontaneous recovery, improvements typically plateau a year after a stroke. Therefore, novel approaches capable of restoring or augmenting lost motor behaviors are needed. Brain-computer interfaces (BCIs) may offer one such approach by using neurophysiological activity underlying hand movements to control an upper extremity orthosis. To test the performance of such a system, we developed an electroencephalogram-based BCI controlled electrically actuated hand orthosis. Six able-bodied participants voluntarily grasped/relaxed one hand to elicit BCI-mediated closing/opening of the orthosis mounted on the opposite hand. Following a short training/calibration procedure, participants demonstrated real-time, online control of the orthosis by following computer cues. Their performances resulted in an average of 1.15 (standard deviation: 0.85) false alarms and 0.22 (0.36) omissions per minute. Analysis of signals from electrogoniometers mounted on both hands revealed an average correlation between voluntary and BCI-mediated movements of 0.58 (0.13), with all but one online performance being statistically significant. This suggests that a BCI driven hand orthosis is feasible, and therefore should be tested in stroke individuals with hand weakness. If proven viable, this technology may provide a novel approach to the neuro-rehabilitation of hand function after stroke.
Abstract-An innovative sensor is developed to evaluate hardness of human soft tissue. This sensor provides easy and accurate hardness measurements based on a unique sensing mechanism. Hardness of soft materials is often evaluated by using international standards of hardness such as IRHD (International Rubber Hardness Degree) and durometer hardness. However the conventional scales based on these standards requires a stable pressuring condition to the target. Therefore, these scales cannot be used for targets that are in motion or targets that require quick measurement such as human muscles during exercises and a liver exposed at a surgery. The prototyped sensor has a compact body and allows continuous hardness measurement with an arbitrary pressing force. This sensor always monitors the force exerted on the sensor and automatically eliminates the unintended effect from the fluctuation of the pressing force. Therefore, continuous time series of the hardness data is real-timely available. This paper reports results of a test as well as the detail of the mechanism and data processing technique of the latest version of the sensor.
Continuous maintenance of an appropriate position of the mandible and head purely by manual manipulation is difficult, although the maneuver can restore airway patency during sleep and anesthesia. The aim of this paper was to examine the effect of head elevation with jaw closure using a remote-controlled airbag device, such as the airbag system, on passive upper airway collapsibility during propofol anesthesia. Seven male subjects were studied. Propofol infusion was used for anesthesia induction and maintenance, with a target blood propofol concentration of 1.5–2 \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{upgreek} \usepackage{mathrsfs} \setlength{\oddsidemargin}{-69pt} \begin{document} }{}\(\mu \) \end{document}g/ml. Nasal mask pressure (\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{upgreek} \usepackage{mathrsfs} \setlength{\oddsidemargin}{-69pt} \begin{document} }{}\({P}_{\text {N}}\) \end{document}) was intermittently reduced to evaluate upper airway collapsibility (passive \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{upgreek} \usepackage{mathrsfs} \setlength{\oddsidemargin}{-69pt} \begin{document} }{}\({P}_{_{\text {CRIT}}}\) \end{document}) and upstream resistance (\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{upgreek} \usepackage{mathrsfs} \setlength{\oddsidemargin}{-69pt} \begin{document} }{}\({R}_{_{\text {US}}}\) \end{document}) at three different head and jaw positions, jaw opening position in the supine position, jaw opening position in the sniffing position with 6-cm head elevation, and jaw closure at a 6-cm height sniffing position. The 6-cm height sniffing position with jaw closure was achieved by an airbag device that was attached to the subject’s head-like headgear. Patient demographics, \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{upgreek} \usepackage{mathrsfs} \setlength{\oddsidemargin}{-69pt} \begin{document} }{}\({P}_{_{\text {CRIT}}}\) \end{document} and \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{upgreek} \usepackage{mathrsfs} \setlength{\oddsidemargin}{-69pt} \begin{document} }{}\({R}_{_{\text {US}}}\) \end{document} in each condition were compared using one-way ANOVA with a post hoc Tukey test. \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{upgreek} \usepackage{mathrsfs} \setlength{\oddsidemargin}{-69pt} \begin{document} }{}\({\rm P}<0.05\) \end{document} was considered ...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.