This study investigates the effects of five decontamination methods on the filter quality (qf) of three commercially available electret masks—N95, Gauze and Spunlace nonwoven masks. Newly developed evaluation methods, the overall filter quality (qf,o) and the qf ratio were applied to evaluate the effectiveness of decontamination methods for respirators. A scanning mobility particle sizer is utilized to measure the concentration of polydispersed particles with diameter 14.6–594 nm. The penetration of particles and pressure drop (Δp) through the mask are used to determine qf and qf,o. Experimental results reveal that the most penetrating particle size (MPS) for the pre-decontaminated N95, Gauze and Spunlace masks were 118 nm, 461 nm and 279 nm, respectively, and the respective penetration rates were 2.6%, 23.2% and 70.0%. The Δp through the pretreated N95 masks was 9.2 mm H2O at the breathing flow rate of heavy-duty workers, exceeding the Δp values obtained through Gauze and Spunlace masks. Decontamination increased the sizes of the most penetrating particles, changing the qf values of all of the masks: qf fell as particle size increased because the penetration increased. Bleach increased the Δp of N95, but destroyed the Gauze mask. However, the use of an autoclave reduces the Δp values of both the N95 and the Gauze mask. Neither the rice cooker nor ethanol altered the Δp of the Gauze mask. Chemical decontamination methods reduced the qf,o values for the three electret masks. The value of qf,o for PM0.1 exceeded that for PM0.1–0.6, because particles smaller than 100 nm had lower penetration, resulting in a better qf for a given pressure drop. The values of qf,o, particularly for PM0.1, reveal that for the tested treatments and masks, physical decontamination methods are less destructive to the filter than chemical methods. Nevertheless, when purchasing new or reusing FFRs, penetration should be regarded as the priority.
In the present study, a theoretical model was used to examine factors affecting the filtration characteristics of filters used for respiratory protection. This work was designed to support the particulate filter test requirements established in 1996. The major operating parameters examined in this work include face velocity, fiber diameter, packing density, filter thickness, and fiber charge density. Characteristics of the most penetrating particle size were also modeled with the same operating parameters.The results showed that aerosol penetration through electret filter media increases with increasing face velocity and increasing fiber diameter, and decreases as packing density, filter thickness or fiber charge density increase. Face velocity and fiber charge density have more significant effects on filter quality than the other factors. Filter quality increases with decreasing face velocity or increasing fiber charge density. For electret filters, (1) the most penetrating particle size increases with increasing fiber diameter; (2) an increase in packing density, thickness, or fiber charge density would cause the most penetrating particle size to decrease, and (3) the most penetrating particle size through electret filters increases with increasing face velocity and decreasing filter thickness. On the other hand, for non-electret filter media, the most penetrating particle size increases with decreasing face velocity, and the filter quality factor is not affected by filter thickness.
This work measures the penetration of ultrafine particles through a single-stage and a two-stage ESP as a function of particle size. Also studied herein are how parameters including particle size, rate of airflow through the ESP, and voltage of the discharging electrode affect aerosol penetration through the ESP. Monodisperse particles with sizes between 10 and 60 nm were generated as the challenge aerosols to investigate the particle charges given by an ESP. A comparison of experimental and theoretical results confirms that a partial charging regime exists when the particle diameter is several tens of nanometers. Experimental results indicated that aerosol penetration through the single- and two-stage ESPs increased significantly for particles below 20 and 50 nm, respectively. However, the exact regime depends on the parameters including airflow rate, applied voltage, and configuration of the ESP. Phenomena such as ionic flow, particle space charge, and flow turbulence may significantly affect the collection efficiency of an ESP for ultrafine particles. To achieve the same collection efficiency, it is more economical to use single-stage ESPs to collect particles less than 16 nm from the standpoint of energy consumption. However, it is more economical to use two-stage ESPs to collect particles larger than 16 nm.
This study quantitatively determined the effect of electrostatic charge on the performance of an electret filtering facepiece. Monodisperse challenge corn oil aerosols with uniform charges were generated using a modified vibrating orifice monodisperse aerosol generator. The aerosol size distributions and concentrations upstream and downstream of an electret filter were measured using an aerodynamic particle sizer, an Aerosizer, and a scanning mobility particle sizer. The aerosol charge was measured by using an aerosol electrometer. The tested electret filter had a packing density of about 0.08, fiber size of 3 microns, and thickness of 0.75 mm. As expected, the primary filtration mechanisms for the micrometer-sized particles are interception and impaction, especially at high face velocities, while electrostatic attraction and diffusion are the filtration mechanisms for submicrometer-sized aerosol particles. The fiber charge density was estimated to be 1.35 x 10(-5) coulomb per square meter. After treatment with isopropanol, most of fiber charges were removed, causing the 0.3-micron aerosol penetration to increase from 36 to 68%. The air resistance of the filter increased slightly after immersion in the isopropanol, probably due to the coating of impurities in isopropanol. The aerosol penetration decreased with increasing aerosol charge. The most penetrating aerosol size became larger as the aerosol charge increased, e.g., from 0.32 to 1.3 microns when the aerosol charge increased from 0 to 500 elementary charges.
Humans produce exhaled breath particles (EBPs) during various breath activities, such as normal breathing, coughing, talking, and sneezing. Airborne transmission risk exists when EBPs have attached pathogens. Until recently, few investigations had evaluated the size and concentration distributions of EBPs from mechanically ventilated patients with different ventilation mode settings. This study thus broke new ground by not only evaluating the size concentration distributions of EBPs in mechanically ventilated patients, but also investigating the relationship between EBP level and positive expiratory end airway pressure (PEEP), tidal volume, and pneumonia. This investigation recruited mechanically ventilated patients, with and without pneumonia, aged 20 years old and above, from the respiratory intensive care unit of a medical center. Concentration distributions of EBPs from mechanically ventilated patients were analyzed with an optical particle analyzer. This study finds that EBP concentrations from mechanically ventilated patients during normal breathing were in the range 0.47–2,554.04 particles/breath (0.001–4.644 particles/mL). EBP concentrations did not differ significantly between the volume control and pressure control modes of the ventilation settings in the mechanically ventilated patients. The patient EBPs were sized below 5 µm, and 80% of them ranged from 0.3 to 1.0 µm. The EBPs concentrations in patients with high PEEP (> 5 cmH2O) clearly exceeded those in patients with low PEEP (≤ 5 cmH2O). Additionally, a significant negative association existed between pneumonia duration and EBPs concentration. However, tidal volume was not related to EBPs concentration.
BackgroundDNMT3A gene mutation has been associated with poor prognosis in acute myeloid leukemia, but its clinical implications in myelodysplastic syndrome (MDS) and dynamic changes during disease progression remain controversial.ResultsIn this study, DNMT3A mutation was identified in 7.9% of 469 de novo MDS patients. DNMT3A-mutated patients had higher platelet counts at diagnosis, and patients with ring sideroblasts had the highest incidence of DNMT3A mutations, whereas those with multilineage dysplasia had the lowest incidence. Thirty-one (83.8%) of 37 DNMT3A-mutated patients had additional molecular abnormalities at diagnosis, and DNMT3A mutation was highly associated with mutations of IDH2 and SF3B1. Patients with DNMT3A mutations had a higher risk of leukemia transformation and shorter overall survival. Further, DNMT3A mutation was an independent poor prognostic factor irrespective of age, IPSS-R, and genetic alterations. The sequential study demonstrated that the original DNMT3A mutations were retained during follow-ups unless allogeneic hematopoietic stem cell transplantation was performed, while DNMT3A mutation was rarely acquired during disease progression.ConclusionsDNMT3A mutation predicts unfavorable outcomes in MDS and was stable during disease evolutions. It may thus be a potential biomarker to predict prognosis and monitor the treatment response.Electronic supplementary materialThe online version of this article (10.1186/s13148-018-0476-1) contains supplementary material, which is available to authorized users.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.