This study was conducted to investigate the protection of disposable filtering half-facepiece respirators of different grades against particles between 0.093 and 1.61 μm. A personal sampling system was used to particle size-selectively assess the protection of respirators. The results show that about 10.9% of FFP2 respirators and 28.2% of FFP3 respirators demonstrate assigned protection factors (APFs) below 10 and 20, which are the levels assigned for these respirators by the British Standard. On average, the protection factors of FFP respirators were 11.5 to 15.9 times greater than those of surgical masks. The minimum protection factors (PFs) were observed for particles between 0.263 and 0.384 μm. No significant difference in PF results was found among FFP respirator categories and particle size. A strong association between fit factors and protection factors was found. The study indicates that FFP respirators may not achieve the expected protection level and the APFs may need to be revised for these classes of respirators.
In the present study, a theoretical model was used to examine factors affecting the filtration characteristics of filters used for respiratory protection. This work was designed to support the particulate filter test requirements established in 1996. The major operating parameters examined in this work include face velocity, fiber diameter, packing density, filter thickness, and fiber charge density. Characteristics of the most penetrating particle size were also modeled with the same operating parameters.The results showed that aerosol penetration through electret filter media increases with increasing face velocity and increasing fiber diameter, and decreases as packing density, filter thickness or fiber charge density increase. Face velocity and fiber charge density have more significant effects on filter quality than the other factors. Filter quality increases with decreasing face velocity or increasing fiber charge density. For electret filters, (1) the most penetrating particle size increases with increasing fiber diameter; (2) an increase in packing density, thickness, or fiber charge density would cause the most penetrating particle size to decrease, and (3) the most penetrating particle size through electret filters increases with increasing face velocity and decreasing filter thickness. On the other hand, for non-electret filter media, the most penetrating particle size increases with decreasing face velocity, and the filter quality factor is not affected by filter thickness.
Humans produce exhaled breath particles (EBPs) during various breath activities, such as normal breathing, coughing, talking, and sneezing. Airborne transmission risk exists when EBPs have attached pathogens. Until recently, few investigations had evaluated the size and concentration distributions of EBPs from mechanically ventilated patients with different ventilation mode settings. This study thus broke new ground by not only evaluating the size concentration distributions of EBPs in mechanically ventilated patients, but also investigating the relationship between EBP level and positive expiratory end airway pressure (PEEP), tidal volume, and pneumonia. This investigation recruited mechanically ventilated patients, with and without pneumonia, aged 20 years old and above, from the respiratory intensive care unit of a medical center. Concentration distributions of EBPs from mechanically ventilated patients were analyzed with an optical particle analyzer. This study finds that EBP concentrations from mechanically ventilated patients during normal breathing were in the range 0.47–2,554.04 particles/breath (0.001–4.644 particles/mL). EBP concentrations did not differ significantly between the volume control and pressure control modes of the ventilation settings in the mechanically ventilated patients. The patient EBPs were sized below 5 µm, and 80% of them ranged from 0.3 to 1.0 µm. The EBPs concentrations in patients with high PEEP (> 5 cmH2O) clearly exceeded those in patients with low PEEP (≤ 5 cmH2O). Additionally, a significant negative association existed between pneumonia duration and EBPs concentration. However, tidal volume was not related to EBPs concentration.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.