The sensitivity of monocrystalline solar module towards dust accumulation and cloud cover is investigated from May to August 2015 for Niamey's environment. Two solar modules with the same characteristics have been used to assess the impacts of the dust on the solar PV module. One of the modules is being cleaned every morning and the second one was used for monitoring the effect of dust accumulation onto the surface of the unclean module for May and June. Results show that dust accumulation has a great effect on decreasing the daily energy yield of the unclean module. But this effect is a long-term effect. For the cloud cover, the effect is immediate. It was estimated that exposing the module into the environment in 23 days in June 2015 has reduced the daily energy yield by 15.29%. This limitation makes solar PV an unreliable source of power for remote devices and thus strongly suggests the challenges of cleaning the module's surface regularly.
In this work, the influence of magnetic field on I-V characteristics of bifacial silicon solar cell n+-p-p+ structure is studied under constant multispectral illumination. After resolution of continuity equation related to photogenerated minority carriers’ density in the base region of this cell, MATLAB numerical simulations of excess minority carriers’, photocurrent densities and junction photovoltage profiles, have been developed with magnetic field in the bulk of the base region. In the same way, the IV characteristics have been studied with magnetic field. It has been demonstrated that the I–V characteristics decreased. It also has shown how the I–V characteristics changed.
PurposeTo study the management and evaluate anatomical and functional outcomes of patients with ipsilateral proximal and shaft femoral fractures.MethodsA retrospective, descriptive and analytic study lasted for ten years and a half ranging from January 1, 2005 to June 30, 2015. The following parameters were studied: epidemiology, fracture characteristics, therapeutic, anatomical and functional outcomes. The correlation between different parameters was analyzed with Fischer test. The significant threshold was defined for p value <0.05.ResultsTen medical files were registered. There were 7 men and 3 women, with a sex ratio of 2.33. The average age was 46 years (range: 29–62 years). It was about traffic road accidents in all cases. Motorcycle–motorcycle and motorcycle–car collision were most frequent. Average admission delay was 7 h (range: 1.5–24 h). Left side was most reached in 8 cases. According to Garden classification, there was type III cervical fracture in 2 cases, type II in 1 case and type IV in 1 case. According to Ender classification, there was type I trochanteric fracture in 3 cases, type VI in 2 cases and type VII in 1 case. According to AO classification, there was type A shaft fracture in 6 cases (A2 in 4 cases and A3 in 2 cases), type B in 2 cases (B1 in 1 case and B2 in 1 case) and type C in 2 cases (C1 in 1 case and C2 in 1 case). Average surgical delay was 28.7 days (range: 11–61 days). For proximal femoral fracture, Moore prosthesis was used in 1 case, blade plate 130° in 2 cases, long Gamma nail in 4 cases, double screwing in 2 cases and dynamic hip screw in 1 case. For shaft femoral fracture, blade plate 95° was used in 3 cases, low compressive plate in 2 cases. Osseous contention was achieved in 4 cases with long Gamma nail and in 1 case with long blade plate 130°. Nonunion of cervical fracture was achieved in 2 cases. The average osseous healing delay was 5.14 months (range: 3–12 months) for proximal femoral fracture and 5 months (range: 3–8 months) for shaft femoral fractures. According to Friedman and Wyman criteria, functional results were good in 4 cases, average in 4 cases and bad in 2 cases. Regarding implants, healing delay showed no statistic difference between one-implant group and two-implant group (p = 0.52), and among the patients with different functional outcomes (p = 0.52). Functional outcomes showed no statistic difference between one-implant group and two-implant group (p = 0.46).ConclusionIpsilateral proximal and shaft femoral fractures are relatively uncommon in our daily activities. It is difficult to recognize proximal femoral fractures which are unnoticed. Results are generally good if the doctors take the two fractures into account in the management.
We use two series of eight-month UHF radar observations collected during the dry and wet seasons of AMMA field campaign. The ultimate goal is to do preliminary work to know whether the lowest layers are suitable for wind energy applications. Surface wind is usually weak in West Africa, but the regular occurrence of a nocturnal low level jet (NLLJ) could provide interesting conditions for wind energy. This work is two-fold: it first aims at improving our knowledge about the NLLJ in West Africa regarding its structure and its variability during the year. Then, special attention is paid to the first 200 m agl, to study the possibility to use the sub-jet wind as a source of energy. A set of enhanced radiosoundings is taken to help to understand the dynamics and thermodynamics and to find a way to extrapolate the wind at low level, where the UHF radars do not provide data.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.