It can be concluded that the effective shielding area is an important parameter in thyroid gland dose reduction. Lead frontal collars with large effective shielding areas (>~300 cm but not necessarily very large) are appropriate for an optimized thyroid gland dose reduction particularly for the critical patients in dental panoramic imaging. Regardless of the shape and thickness, using the Pb-equivalent shields is not justifiable in dental panoramic imaging.
In this work several studies have been conducted on hard x-ray emissions of Damavand tokamak based on radiation dosimetry using the Thermoluminescence method. The goal was to understand interactions of runaway electrons with plasma particles, vessel wall, and plasma facing components. Total of 354 GR-200 (LiF:Mg,Cu,P) thermoluminescence dosimeter (TLD) crystals have been placed on 118 points--three TLDs per point--to map hard x-ray radiation doses on the exterior of the vacuum vessel. Results show two distinctive levels of x-ray radiations doses on the exterior of the vessel. The low-dose area on which measured dose is about 0.5 mSv/shot. In the low-dose area there is no particular component inside the vessel. On the contrary, on high-dose area of the vessel, x-ray radiations dose exceeds 30 mSv/shot. The high-dose area coincides with the position of limiters, magnetic probe ducts, and vacuum vessel intersections. Among the high-dose areas, the highest level of dose is measured in the position of the limiter, which could be due to its direct contact with the plasma column and with runaway electrons. Direct collisions of runaway electrons with the vessel wall and plasma facing components make a major contribution for production of hard x-ray photons in Damavand tokamak.
The type testing of measuring devices is one of the most important parts of a quality management system in a personal dosimetry services program. In this study, based upon the International Electrotechnical Commission (IEC) 62387 criteria, a reader-testing program was performed for a home-made personal thermoluminescent dosimetry (TLD) reader. The stability of the reader, the effects of light exposure, temperature and fluctuations of primary power supply on TLD read-outs as the main parameters were investigated in this program. Moreover, this study assesses some important criteria of dosimetry system including the non-linearity of response, reusability, after effect and overload that may include significant contribution in the performance of a reader. The results showed that the TLD reader met all requirements of the IEC for the reader tests by a large margin.
The general population, everywhere in the world is exposed to a small dose of ionising radiation from natural sources. Stochastic effects such as cancer and genetic disorders are caused when living creatures are exposed to low doses. In Iran, it is measured in some cities, especially in high-background areas such as Ramsar, but so far there is no measurement in the Hamadan province. Hamadan is located in the west of Iran. Measurements were performed using a RDS-110 survey meter, CaSO(4):Dy thermoluminecense dosimetries (TLDs) and a Harshaw 4000 TLD reader. To estimate the dose rate outdoors, four stations along the main directions (north, south, west and east) and one in the town centre were selected. Mean annual X and gamma equivalent dose in Hamadan province are 1.12±0.22 and 1.66±0.07 mSv, which related to RDS-110 survey meter and TLDs measurements, respectively. The TLDs and RDS-110 results are representative of the external photon radiation doses for the selected monitoring locations and for those locations for the hours during which the measurements were taken, respectively. Maximum and minimum of external photon radiation doses are related to Hamadan and Kaboudar-Ahang towns, respectively. According to the results of the study, it seems that the annual X and gamma equivalent dose in Hamadan province exceeded the global mean external exposure amounts by the UNSCEAR, and further studies are needed to measure internal exposures to determine the total environmental radiation level in Hamadan province.
The effect of pre-irradiation annealing in an oven at 240 degrees C/10 min (oven anneal) and in a TLD reader at 6 degrees C s(-1), 10 s dwell time at a maximum temperature 240 degrees C (reader anneal), on the glow curve structure of a home made sample of LiF:Mg,Cu,P powder has been investigated. It is shown that on oven annealing the glow peak areas of peaks 2 and 3 increase and that of peak 4 decreases, while on reader annealing the area of peak 4 increases and those of peaks 2 and 3 effectively decrease. Values of fading during a post-irradiation storage of 6 months were measured to be 26% and 12% for samples undergoing oven and reader annealing respectively. To reduce the effect of fading several pre-heats at temperatures of 100, 110, 120 and 130 degrees C for 10 min were investigated and 120 degrees C/10 min was chosen as the optimal condition for pre-heat. It is also observed that when imposing pre-heat thermal treatment on this dosimeter or storing the irradiated dosimeter the height of peak 4 effectively increases while the integral of TL signals remains constant.
This report presents status of external and internal dose assessment of workers and introducing the structure of National Dose Registry System of Iran (NDRSI). As well as types of individual dosemeters in use, techniques for internal dose assessment are presented. Results obtained from the International Atomic Energy Agency intercomparison programme on measurement of personal dose equivalent H(p) (10) and consistency of the measured doses with the delivered doses are shown. Also, implementation of dosimetry standards, establishment of quality management system, authorisation and approval procedure of dosimetry service providers are discussed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.