Clinical studies have established a strong benefit from adjuvant mild hyperthermia (HT) to radio- and chemotherapy for many tumor sites, including the head and neck (H&N). The recently developed HYPERcollar allows the application of local radiofrequency HT to tumors in the entire H&N. Treatment quality is optimized using electromagnetic and thermal simulators and, whenever placement risk is tolerable, assessed using invasively placed thermometers. To replace the current invasive procedure, we are investigating whether magnetic resonance (MR) thermometry can be exploited for continuous and 3D thermal dose assessment. In this work, we used our simulation tools to design an MR compatible laboratory prototype applicator. By simulations and measurements, we showed that the redesigned patch antennas are well matched to 50 Ω (S11<-10 dB). Simulations also show that, using 300 W input power, a maximum specific absorption rate (SAR) of 100 W kg(-1) and a temperature increase of 4.5 °C in 6 min is feasible at the center of a cylindrical fat/muscle phantom. Temperature measurements using the MR scanner confirmed the focused heating capabilities and MR compatibility of the setup. We conclude that the laboratory applicator provides the possibility for experimental assessment of the feasibility of hybrid MR-HT in the H&N region. This versatile design allows rigorous analysis of MR thermometry accuracy in increasingly complex phantoms that mimic patients' anatomies and thermodynamic characteristics.
Mobile medical imaging devices are invaluable for clinical diagnostic purposes both in and outside healthcare institutions. Among the various imaging modalities, only a few are readily portable. Magnetic resonance imaging (MRI), the gold standard for numerous healthcare conditions, does not traditionally belong to this group. Recently, low-field MRI technology companies have demonstrated the first decisive steps towards portability within medical facilities and vehicles. However, these scanners’ weight and dimensions are incompatible with more demanding use cases such as in remote and developing regions, sports facilities and events, medical and military camps, or home healthcare. Here we present in vivo images taken with a light, small footprint, low-field extremity MRI scanner outside the controlled environment provided by medical facilities. To demonstrate the true portability of the system and benchmark its performance in various relevant scenarios, we have acquired images of a volunteer’s knee in: (i) an MRI physics laboratory; (ii) an office room; (iii) outside a campus building, connected to a nearby power outlet; (iv) in open air, powered from a small fuel-based generator; and (v) at the volunteer’s home. All images have been acquired within clinically viable times, and signal-to-noise ratios and tissue contrast suffice for 2D and 3D reconstructions with diagnostic value. Furthermore, the volunteer carries a fixation metallic implant screwed to the femur, which leads to strong artifacts in standard clinical systems but appears sharp in our low-field acquisitions. Altogether, this work opens a path towards highly accessible MRI under circumstances previously unrealistic.
We present a magnet and high power electronics for Prepolarized Magnetic Resonance Imaging (PMRI) in a homemade, special-purpose preclinical system designed for simultaneous visualization of hard and soft biological tissues. PMRI boosts the signal-to-noise ratio (SNR) by means of a long and strong magnetic pulse which must be rapidly switched off prior to the imaging pulse sequence, in timescales shorter than the spin relaxation (or 𝑇 1 ) time of the sample. We have operated the prepolarizer at up to 0.5 T and demonstrated enhanced magnetization, image SNR and tissue contrast with PMRI of tap water, an ex vivo mouse brain and food samples. These have 𝑇 1 times ranging from hundreds of milli-seconds to single seconds, while the preliminary high-power electronics setup employed in this work can switch off the prepolarization field in tens of milliseconds. In order to make this system suitable for solid-state matter and hard tissues, which feature 𝑇 1 times as short as 10 ms, we are developing new electronics which can cut switching times to ∼ 300 μs. This does not require changes in the prepolarizer module, opening the door to the first experimental demonstration of PMRI on hard biological tissues.
The techniques presented here may be used to simplify calibration experiments that use an interstitial heating device, or any heating method that provides rapid and spatially localised heat distributions. Overall, the experimental verification of the data registration and PRFS thermal coefficient calibration technique provides a useful benchmarking method to maximise MRT accuracy in any similar context.
We describe with a theoretical and numerical analysis the use of small permanent magnets moving along prescribed helical paths for 3D spatial encoding and imaging without sample adjustment in ultra-low field magnetic resonance imaging (ULF-MRI). With our developed method the optimal magnet path and orientation for a given encoding magnet number and instrument architecture can be determined. As a proof-of-concept, we studied simple helical magnet paths and lengths for one and two encoding magnets to evaluate the imaging efficiency for a mechanically operated ULF-MRI instrument with permanent magnets. We demonstrate that a single encoding magnet moving around the sample in a single revolution suffices for the generation of a 3D image by back projection.
Air-core magnetometers are amongst the most commonly used magnetic field detectors in biomedical instruments. They offer excellent sensitivity, low fabrication complexity and a robust, cost-effective solution. However, air-core magnetometers must be tailored to the specific application to achieve high sensitivity, which can be decisive in the accuracy of the diagnoses and the time required for the examination. Existing methods proposed for the design of air-core magnetometers are based on simplified models and simulations using a reduced number of variables, potentially leading to sensitivity that is suboptimal. To circumvent this we chose a method with fewer assumptions and a larger number of decision variables which employed a genetic algorithm, a global optimisation method. Experimental validation shows that the model is appropriate for the design of highly sensitive air-core magnetometers. Moreover, our results support the suitability of a genetic algorithm for optimization in this context. The new method described herein will be made publicly available via our website to facilitate the development of less costly biomedical instruments using air-core magnetometers with unprecedented sensitivity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.