The ability to accelerate the spatial encoding process during a chemical shift imaging (CSI) scan of hyperpolarized compounds is demonstrated through parallel imaging. A hardware setup designed to simultaneously acquire (13)C data from multiple receivers is presented here. A system consisting of four preamplifiers, four gain stages, a transmit coil, and a four receive channel rat coil was built for single channel excitation and simultaneous multi-channel detection of (13)C signals. The hardware setup was integrated with commercial scanner electronics, allowing the system to function similar to a conventional proton multi-channel setup, except at a different frequency. The ability to perform parallel imaging is demonstrated in vivo. CSI data from the accelerated scans are reconstructed using a self-calibrated multi-spectral parallel imaging algorithm, by using lower resolution coil sensitivity maps obtained from the central region of k-space. The advantages and disadvantages of parallel imaging in the context of imaging hyperpolarized compounds are discussed.
MR-guided interventional procedures can be performed with full patient access with use of an open-configuration, superconducting MR magnet with near real-time imaging and interactive image plane control.
Deep lying soft tissue tumors may be treated by a nonincisional surgical procedure executed inside an MR imaging system using a thermal effect delivered by a focused ultrasound transducer. A prototype system is constructed to assess MRI thermal monitoring and the localization of the heat zone in muscle. The temperature distribution of the focal spot is imaged with MRI while mechanically moving the transducer with an hydraulic 3-axis positioner. Acoustic power is applied with a spherical shell transducer using 1- to 10-s duration pulses at frequencies of 1.5 MHz to selectively coagulate tissue at 60-70 degrees C. The procedure is monitored with a series of fast second gradient echo, T1-weighted, temperature sensitive MR sequences. Acquisitions are optimized for high temperature sensitive images that yield the thermal diffusivity, heat flow time constant and the focal spot size in muscle. MR temperature maps of muscle provide localization and dosimetry both in the focal region and near field.
A demonstration of MR guided thermal surgery involved experiments with imaging of focused ultrasound in an MRI system, measurements of the thermal transients and a thermal analysis of the resulting images. Both the heat distribution and the creation of focused ultrasound lesions in gel phantoms, in vitro bovine muscle and in vivo rabbit muscle were monitored with magnetic resonance imaging. Thermal surgical procedures were modeled by an elongated gaussian heat source where heat flow is controlled by tissue thermal properties and tissue perfusion. Temperature profiles were measured with thermocouples or calculated from magnetic resonance imaging in agreement with the model. A 2-s T1-weighted gradient-refocused acquisition provided thermal profiles needed to localize the heat distribution produced by a 4-s focused ultrasound pulse. Thermal analysis of the images give an effective thermal diffusion coefficient of 0.0015 cm2/s in gel and 0.0033 cm2/s in muscle. The lesions were detected using a T2-weighted spin-echo or fast spin-echo pulse sequence in agreement with muscle tissue sections. Potential thermal surgery applications are in the prostate, liver, kidney, bladder, breast, eye and brain.
Purpose
A novel prospective motion correction technique for brain MRI is presented that uses miniature wireless radio-frequency (RF) coils, or “wireless markers”, for position tracking.
Methods
Each marker is free of traditional cable connections to the scanner. Instead, its signal is wirelessly linked to the MR receiver via inductive coupling with the head coil. Real-time tracking of rigid head motion is performed using a pair of glasses integrated with three wireless markers. A tracking pulse-sequence, combined with knowledge of the markers’ unique geometrical arrangement, is used to measure their positions. Tracking data from the glasses is then used to prospectively update the orientation and position of the image-volume so that it follows the motion of the head.
Results
Wireless-marker position measurements were comparable to measurements using traditional wired RF tracking coils, with the standard deviation of the difference < 0.01 mm over the range of positions measured inside the head coil. RF safety was verified with B1 maps and temperature measurements. Prospective motion correction was demonstrated in a 2D spin-echo scan while the subject performed a series of deliberate head rotations.
Conclusion
Prospective motion correction using wireless markers enables high quality images to be acquired even during bulk motions. Wireless markers are small, avoid RF safety risks from electrical cables, are not hampered by mechanical connections to the scanner, and require minimal setup times. These advantages may help to facilitate adoption in the clinic.
Noninvasive magnetic resonance temperature maps that are used to monitor thermal ablation of tissue are described. In magnetic resonance images, thermally induced proton nuclear magnetic resonance frequency shifts, and changes in the longitudinal relaxation time produce both phase and magnitude changes in the MR signal. Temperature maps with improved sensitivity are derived from the complex-difference nuclear magnetic resonance signal. Bovine muscle specimens were heated with focused ultrasound to model thermal surgery and create a known thermal distribution to test the method. Resulting MR images acquired in 2 s produce temperature maps with 1 min resolution and 2 degrees C temperature sensitivity. The temperature sensitivity was increased by extending the acquisition to 5 s, by decreasing the receiver bandwidth, and increasing the echo time.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.