Purpose To analyze dynamics of retinal vessel dilation response to flicker light in patients with glaucoma and ocular hypertension. Patients and methods Response to flicker light was measured in retinal vessels by means of Retinal Vessel Analyzer. After the baseline 50 seconds long diameter recording of inferior and superior temporal artery and vein, three flicker stimulations of 20 seconds duration was applied, with a 80 seconds break in between. Area under the curve of the vessel diameter (AUC) was compared during 3 flicker periods in the open angle glaucoma patients group (POAG, n=47) and ocular hypertensives (OHT, n=46) and age-matched healthy controls (n=56) Results POAG eyes demonstrated smaller response of all vessels to flicker light in general than the other two groups (p=0.0008), but the response dynamics was significantly different between the groups (p=0.038), showing in three flicker periods a delayed increasing response in the POAG and OHT groups, and remaining stable in healthy subjects. Conclusion General vessel response to flicker light was decreased in POAG patients despite the slow improvement in repeated flicker stimulation, indicating an altered response pattern.
The maximum dilatory amplitude was significantly lower in vessels in the vasospastic group. An augmentation of the maximum vasodilation was observed in the nonvasospastic group after repeated flicker stimulations, a phenomenon that was missing in arterioles of vasospastic subjects. It seems that such different behavior is due to the opposite baseline offsets in interflicker periods in the two groups.
ABSTRACT.Purpose: This study aimed to determine whether ocular pulse amplitude (OPA) measured with dynamic contour tonometry (DCT) is related to systemic blood pressure (BP) parameters. Methods: Blood pressure was measured continuously and simultaneously with OPA in one randomly selected eye in 29 healthy subjects. Systemic parameters of interest were: systolic and diastolic BPs and their difference (BP amplitude), and left ventricle ejection time (LVET; defined as the time between the diastolic trough and the incisural notch in the BP curve). In addition, the axial length (AL) of the eye was measured. Associations between OPA, AL and systemic cardiovascular parameters were analysed in a multivariate regression model. Results: Measurements of OPA ranged from 1.0 mmHg to 4.9 mmHg (mean 2.3 ± 0.9 mmHg, median 1.9 mmHg). In a univariate analysis with one predictor at a time, means of intraocular pressure (IOP) (p = 0.008), AL (p = 0.046) and LVET (p = 0.037) were significantly correlated with OPA, whereas systolic and diastolic BPs and their amplitude were not. A multiple linear regression analysis showed that mean IOP (p < 0.005), AL (p = 0.01) and LVET (p = 0.002) all independently contributed to OPA. Conclusions: The OPA readings measured with DCT in healthy subjects were not related to BP levels and amplitude. It seems that the OPA strongly depends on the time)course of the cardiac contraction. Regulating mechanisms in the carotid system as well as scleral rigidity may be responsible for dampening the direct effect of BP variations.
General vessel response to flicker light was decreased in POAG patients, compared to normal controls and OHT patients. In contrast to significant correlation between the two contralateral eyes of the flicker response itself, only its borderline correlation to IOP was seen. There was no correlation to the level of damage, altogether indicating a systemic dysregulation phenomenon. GRANTS: Swiss National Foundation Grant 3200B0-113685, Velux Stiftung Grant, Freie Akademische Gesellschaft (FAG) Grant, Pfizer Inc. Grant CLINICAL TRIAL REGISTRATION REFERENCE NUMBER: ClinicalTrials.gov NCT00430209.
ABSTRACT.Purpose: To evaluate the potential of brilliant blue G (BBG) for intraoperative staining of the inner limiting membrane (ILM) with respect to staining properties and surgical outcome. Methods: In a retrospective, non-comparative clinical case series, we analysed 17 consecutive chromovitrectomy interventions for surgery of macular holes, ERMs, vitreoretinal traction syndromes and cystoid macular oedema. Following complete posterior vitreous detachment, BBG was injected into the vitreous cavity at a concentration of 0.25 mg ⁄ ml, followed by immediate washout. Main outcome measures were staining properties, visual acuity, central visual field testing and optical coherence tomography (OCT) measurements over a mean follow-up period of 3 months. Results: ILM staining was somewhat less intensive for BBG than for average indocyanine green (ICG) chromovitrectomy. However, the ILM was removed successfully without additional ICG in 15 ⁄ 17 patients. Postoperative visual acuity was improved in 16 ⁄ 17 patients and remained unchanged in one patient. Central retinal OCT thickness showed a postoperative reduction, with values ranging from +7 to )295 lm (median )89 lm). Neither visual field defects nor any other adverse events were recorded. Conclusion: BBG permits sufficient staining for safe ILM removal. In this short-term study, good anatomical and functional results were achieved and no adverse events were observed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.