Documented variations in the isotopic compositions of some chemical elements are responsible for expanded uncertainties in the standard atomic weights published by the Commission on Atomic Weights and Isotopic Abundances of the International Union of Pure and Applied Chemistry. This report summarizes reported variations in the isotopic compositions of 20 elements that are due to physical and chemical fractionation processes (not due to radioactive decay) and their effects on the standard atomic-weight uncertainties. For 11 of those elements (hydrogen, lithium, boron, carbon, nitrogen, oxygen, silicon, sulfur, chlorine, copper, and selenium), standard atomic-weight uncertainties have been assigned values that are substantially larger than analytical uncertainties because of common isotope-abundance variations in materials of natural terrestrial origin. For 2 elements (chromium and thallium), recently reported isotope-abundance variations potentially are large enough to result in future expansion of their atomic-weight uncertainties. For 7 elements (magnesium, calcium, iron, zinc, molybdenum, palladium, and tellurium), documented isotope variations in materials of natural ter- restrial origin are too small to have a significant effect on their standard atomic-weight uncertainties. This compilation indicates the extent to which the atomic weight of an element in a given material may differ from the standard atomic weight of the element. For most elements given above, data are graphically illustrated by a diagram in which the materials are specified in the ordinate and the compositional ranges are plotted along the abscissa in scales of (1) atomic weight, (2) mole fraction of a selected isotope, and (3) delta value of a selected isotope ratio.
New results are reported from an ongoing international research effort to accurately determine the Avogadro constant by counting the atoms in an isotopically enriched silicon crystal. The surfaces of two 28 Si-enriched spheres were decontaminated and reworked in order to produce an outer surface without metal contamination and improved sphericity. New measurements were then made on these two reconditioned spheres using improved methods and apparatuses. When combined with other recently refined parameter measurements, the Avogadro constant derived from these new results has a value of N A = 6.022 140 76(12) × 10 23 mol -1 . The X-ray crystal density method has thus achieved the target relative standard uncertainty of 2.0 × 10 -8 necessary for the realization of the definition of the new kilogram.
The results of an absolute silicon molar mass determination of two independent sets of samples from the highly 28Si-enriched crystal (AVO28) produced by the International Avogadro Coordination are presented and compared with results published by the Physikalisch-Technische Bundesanstalt (PTB, Germany), the National Research Council (NRC, Canada) and the National Metrology Institute of Japan (NMIJ, Japan). This study developed and describes significant changes to the published protocols for producing absolute silicon isotope ratios. The measurements were made at very high resolution on a multi-collector inductively coupled plasma mass spectrometer using tetramethylammonium hydroxide (TMAH) to dissolve and dilute all samples. The various changes in the measurement protocol and the use of TMAH resulted in significant improvements to the silicon isotope ratio precision over previously reported measurements and in particular, the robustness of the 29Si/30Si ratio of the AVO28 material. These new results suggest that a limited isotopic variability is present in the AVO28 material. The presence of this variability is at present singular and therefore its significance is not well understood. Fortunately, its magnitude is small enough so as to have an insignificant effect on the overall uncertainty of an Avogadro constant derived from the average molar mass of all four AVO28 silicon samples measured in this study. The NIST results confirm the AVO28 molar mass values reported by PTB and NMIJ and confirm that the virtual element–isotope dilution mass spectrometry approach to calibrated absolute isotope ratio measurements developed by PTB is capable of very high precision as well as accuracy. The Avogadro constant NA and derived Planck constant h based on these measurements, together with their associated standard uncertainties, are 6.02214076(19) × 1023 mol−1 and 6.62607017(21) × 10−34 Js, respectively.
Recent developments in morphing aircraft research have motivated investigation into conformal morphing systems, that is, shape change without discrete moving parts or abrupt changes in the airfoil profile. In this study, implementation of a continuous span morphing wing is described. The system consists of two primary components: (1) zero-Poisson ratio morphing core and (2) fiber-reinforced elastomeric matrix composite skin with a nearly zero-Poisson ratio in-plane. The main goal for improved air vehicle efficiency was a nominal 100% change in area of the active wing section with less than 2.54 mm out-of-plane deflection under representative aerodynamic loading. Objectives of this study included exploring fabrication techniques for advanced morphing core shapes (i.e., having airfoil-shaped cross-section), exploiting customizable design parameters of in-house fabricated skin and core material, designing a prototype wing structure such that integration with a candidate UAV was feasible, and experimentally evaluating a laboratory prototype. As a result of this study, the ability to physically build and test a viable airfoil structure capable of increasing its planform area by 100% (doubling span with constant chord) was demonstrated on a prototype hardware demonstration article. Satisfying objectives of designing, fabricating, and testing a prototype morphing wing section capable of 100% span extension, while maintaining constant chord, a wind tunnel test highlighted the resulting viable aerodynamic surface in a wind tunnel test up to 130 km/h wind speeds. The prototype wing in its resting condition had a span of 61.0 cm, which could be extended to 122.0 cm, with less than 2.54 mm out-of-plane deflection in dynamic pressures consistent with the maximum speed, 130 km/h, of a candidate unmanned aerial vehicle platform. In meeting these goals, the morphing core was successfully transitioned from a simple 1D concept into a complex, cambered airfoil with sufficient free volume to house an actuation system. A refined elastomer matrix composite skin fabrication technique was also devised and experimentally validated on skins of various thicknesses and overall dimensions.
Revised delta(34)S reference values with associated expanded uncertainties (95% confidence interval (C.I.)) are presented for the sulfur isotope reference materials IAEA-S-2 (22.62 +/- 0.16 per thousand) and IAEA-S-3 (-32.49 +/- 0.16 per thousand). These revised values are determined using two relative-difference measurement techniques, gas source isotope ratio mass spectrometry (GIRMS) and double-spike multi-collector thermal ionization mass spectrometry (MC-TIMS). Gas analyses have traditionally been considered the most robust for relative isotopic difference measurements of sulfur. The double-spike MC-TIMS technique provides an independent method for value-assignment validation and produces revised values that are both unbiased and more precise than previous value assignments. Unbiased delta(34)S values are required to anchor the positive and negative end members of the sulfur delta (delta) scale because they are the basis for reporting both delta(34)S values and the derived mass-independent Delta(33)S and Delta(36)S values.
The continuous improvement of analytical procedures using multi‐collector technologies in ICP‐mass spectrometry has led to an increased demand for isotope standards with improved homogeneity and reduced measurement uncertainty. For magnesium, this has led to a variety of available standards with different quality levels ranging from artefact standards to isotope reference materials certified for absolute isotope ratios. This required an intercalibration of all standards and reference materials, which we present in this interlaboratory comparison study. The materials Cambridge1, DSM3, ERM‐AE143, ERM‐AE144, ERM‐AE145, IRMM‐009 and NIST SRM 980 were cross‐calibrated with expanded measurement uncertainties (95% confidence level) of less than 0.030‰ for the δ25/24Mg values and less than 0.037‰ for the δ26/24Mg values. Thus, comparability of all magnesium isotope delta (δ) measurements based on these standards and reference materials is established. Further, ERM‐AE143 anchors all magnesium δ‐scales to absolute isotope ratios and therefore establishes SI traceability, here traceability to the SI base unit mole. This applies especially to the DSM3 scale, which is proposed to be maintained. With ERM‐AE144 and ERM‐AE145, which are product and educt of a sublimation–condensation process, for the first time a set of isotope reference materials is available with a published value for the apparent triple isotope fractionation exponent θapp, the fractionation relationship ln α(25/24Mg)/ln α(26/24Mg).
Evaporation experiments were undertaken to determine the volatility of parts-per-million concentrations of boron in water and dilute HCl in the presence and absence of equimolar mannitol and/or cesium. Multiple 10 mL aliquots prepared identically were evaporated to various extents or just to dryness and heated 10-20 min after reaching dryness under filtered air at 60 °C. Boron was only retained quantitatively in water during evaporation and after reaching dryness in the presence of equimolar mannitol and cesium. Boron was retained quantitatively in dilute HCl solution during evaporation, without mannitol or cesium. But it could be retained when the dilute HCl just reached dryness and thereafter only in the presence of equimolar mannitol. Isotopic measurements of the evaporating solutions and residues indicate that the heavier isotope, 11 B, is preferentially lost from the nearneutral and acidic solutions examined. The results are pertinent for procedures requiring preconcentration of boron.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.