We demonstrate for the first time the applicability of antenna-coupled field-effect transistors for the detection of terahertz radiation (TeraFETs) for multi-spectral imaging from 0.76 to 4.25 THz. TeraFETs were fabricated in a commercial 90-nm CMOS process and noise-equivalent powers of 59, 20, 63, 85 and 110 pW/√(Hz) at 0.216, 0.59, 2,52, 3.11 and 4.25 THz, respectively, have been achieved. A set of TeraFETs has been applied in raster-scan transmission and reflection imaging of pellets of sucrose and tartaric acid simulating common plastic explosives. Transmittance values are in good agreement with Fourier-transform infrared spectroscopy data. The spatial distribution of the components in the samples has been determined from the transmission data using principal component analysis.
A terahertz (THz) imaging system based on narrow band microbolometer sensors (NBMS) and a novel diffractive lens was developed for spectroscopic microscopy applications. The frequency response characteristics of the THz antenna-coupled NBMS were determined employing Fourier transform spectroscopy. The NBMS was found to be a very sensitive frequency selective sensor which was used to develop a compact all-electronic system for multispectral THz measurements. This system was successfully applied for principal components analysis of optically opaque packed samples. A thin diffractive lens with a numerical aperture of 0.62 was proposed for the reduction of system dimensions. The THz imaging system enhanced with novel optics was used to image for the first time non-neoplastic and neoplastic human colon tissues with close to wavelength-limited spatial resolution at 584 GHz frequency. The results demonstrated the new potential of compact RT THz imaging systems in the fields of spectroscopic analysis of materials and medical diagnostics.
Suitability of InGaAs-based bow-tie diodes for a spectroscopic terahertz imaging is demonstrated by inspecting explosive simulators packed in a thick plastic container. The transmission images were obtained within the frequency range of 0.58-2.52 THz at room temperature using optimized bow-tie diode connection scheme. Content of sucrose and tartaric acid in the test samples was discriminated. Measured absorbance was found to be in a good correlation with Fourier spectroscopy data. Performance of room temperature THz imaging using the bow-tie diode was compared versus a commercial pyro-electric sensor.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.