• Contrast material and haemorrhage have similar density on conventional 120-kV CT. • Contrast material hinders interpretation of CT in stroke patients after recanalisation. • Iodine and haemorrhage have different attenuation at lower kVs. • Dual energy CT improves accuracy in early differentiation of haemorrhage and contrast extravasation. • Early differentiation between iodine and haemorrhage helps to initiate therapy promptly.
Background and Purpose-The aim of this study was to evaluate the sensitivity and specificity of MR angiography (MRA) in the diagnosis of ruptured and unruptured intracranial aneurysms. Methods-A systematic search was performed on 4 electronic databases on relevant articles that were published from January 1998 to October 2013. Inclusion criteria were met by 12 studies that compared MRA with digital subtraction angiography as reference standard. Two independent reviewers evaluated the methodological quality of the studies. Data from eligible studies were extracted and used to construct 2×2 contingency tables on a per-aneurysm level. Pooled estimates of sensitivity and specificity were calculated for all studies and subgroups of studies. Heterogeneity was tested, and risk for publication bias was assessed. Results-Included studies were of high methodological quality. Studies with larger sample size tended to have higher diagnostic performance. Most studies used time-of-flight MRA technique. Among the 960 patients assessed, 772 aneurysms were present. Heterogeneity with reference to sensitivity and specificity was moderate to high. Pooled sensitivity of MRA was 95% (95% confidence interval, 89%-98%), and pooled specificity was 89% (95% confidence interval, 80%-95%). False-negative and false-positive aneurysms detected on MRA were mainly located at the skull base and middle cerebral artery. Freehand 3-dimensional reconstructions performed by the radiologist significantly increased diagnostic performance. Studies performed on 3 Tesla showed a trend toward higher performance (P=0.054).
Conclusions-Studies
Serum hsCRP was related to the severity of PAD, showing a relation to future hemodynamic function and cardiovascular events in PAD patients. In addition to coronary plaques, aneurysmal aortas, and failed venous coronary bypasses, femoral plaques also produce CRP, thus illustrating that the production of CRP may represent a universal response to vascular injury and suggesting that vascular CRP may contribute to plaque development.
The efficacy of radiation protection glasses depends on the orientation of the operator's head relative to the irradiated volume. Glasses can offer good protection to the eye under clinically relevant conditions. However, the performance in clinical practice in our study was lower than expected. This is likely related to nonoptimized room geometry and training of the staff as well as measurement methodology.
Short-term clinical results using the sinus Venous stent are excellent, with significant symptom reduction, low morbidity rates, and no mortality. Loss of stent patency is seen less often compared with arterial stents described in the literature.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.