Bone mechanical properties are typically evaluated at relatively low strain rates. However, the strain rate related to traumatic failure is likely to be orders of magnitude higher and this higher strain rate is likely to affect the mechanical properties. Previous work reporting on the effect of strain rate on the mechanical properties of bone predominantly used nonhuman bone. In the work reported here, the effect of strain rate on the tensile and compressive properties of human bone was investigated. Human femoral cortical bone was tested longitudinally at strain rates ranging between 0.14-29.1 s(-1) in compression and 0.08-17 s(-1) in tension. Young's modulus generally increased, across this strain rate range, for both tension and compression. Strength and strain (at maximum load) increased slightly in compression and decreased (for strain rates beyond 1 s(-1)) in tension. Stress and strain at yield decreased (for strain rates beyond 1 s(-1)) for both tension and compression. In general, there seemed to be a relatively simple linear relationship between yield properties and strain rate, but the relationships between postyield properties and strain rate were more complicated and indicated that strain rate has a stronger effect on postyield deformation than on initiation of yielding. The behavior seen in compression is broadly in agreement with past literature, while the behavior observed in tension may be explained by a ductile to brittle transition of bone at moderate to high strain rates.
95/5 Poly(L-lactide-co-glycolide) was investigated for the role of a porous scaffold, using the selective laser sintering (SLS) fabrication process, with powder sizes of 50-125 and 125-250 microm. SLS parameters of laser power, laser scan speed, and part bed temperature were altered and the degree of sintering was assessed by scanning electron microscope. Composites of the 125-250 microm polymer with either hydroxylapatite or hydroxylapatite/beta-tricalcium phosphate (CAMCERAM II were sintered, and SLS settings using 40 wt % CAMCERAM II were optimized for further tests. Polymer thermal degradation during processing led to a reduction in number and weight averaged molecular weight of 9% and 12%, respectively. Compression tests using the optimized composite sintering parameters gave a Young's modulus, yield strength, and strain at 1% strain offset of 0.13 +/- 0.03 GPa, 12.06 +/- 2.53 MPa, and 11.39 +/- 2.60%, respectively. Porosity was found to be 46.5 +/- 1.39%. CT data was used to create an SLS model of a human fourth middle phalanx and a block with designed porosity was fabricated to illustrate the process capabilities. The results have shown that this composite and fabrication method has potential in the fabrication of porous scaffolds for bone tissue engineering.
The effect of temperature on the optical properties of human dermis and subdermis as a function of near-infrared wavelength has been studied between 25 degrees C and 40 degrees C. Measurements were performed ex vivo on a total of nine skin samples taken from the abdomen of three individuals. The results show a reproducible effect of temperature on the transport scattering coefficient of dermis and subdermis. The relative change of the transport scattering coefficient showed an increase for dermis ((4.7+/-0.5) x 10(-3) degrees C(-1)) and a decrease for subdermis ((-1.4+/-0.28) x 10(-3) degrees C(-1)). Note that the magnitude of the temperature coefficient of scattering was greater for dermis than subdermis. A reproducible effect of temperature on the absorption coefficient could not be found within experimental errors. System reproducibility in transport scattering coefficient with repeated removal and repositioning of the same tissue sample at the same temperature was excellent at +/-0.35% for all measurements. This reproducibility enabled such small changes in scattering coefficient to be detected.
The vast majority of "non-invasive" measurements of human tissues using near infrared spectroscopy rely on passing light through the dermis and subdermis of the skin. Accurate knowledge of the optical properties of these tissues is essential to put into models of light transport and predict the effects of skin perfusion on measurements of deep tissue. Additionally, the skin could be a useful accessible organ for non-invasively determining the constituents ofblood flowing though it.Samples of abdominal human skin (including subdermal tissue) were obtained from either post mortem examinations or plastic surgery. The samples were separated into a dermal layer (epidermis and dermis, 1 .5 to 2 mm thick), and a sub-cutaneous layer comprised largely of fat. They were enclosed between two glass coverslips and placed in an integrating sphere to measure their reflectance and transmittance over a range of wavelengths from 600 to 1000 urn. The reflectance and transmittance values were converted into average absorption and reduced scattering coefficients by comparison with a Monte Carlo model of light transport. Improvements to the Monte Carlo model and measurement technique removed some previous uncertainties.The results show excellent separation of reduced scattering and absorption coefficient, with clear absorption peaks of hemoglobin, water and lipid. The effect oftissue storage upon measured optical properties was investigated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.