We report an empirical study of the Ibovespa index of the São Paulo Stock Exchange in which we detect the existence of long-range correlations. To analyze our data we introduce a rescaled variant of the usual Detrended Fluctuation Analysis that allows us to obtain the Hurst exponent through a one-parameter fitting. We also compute a time-dependent Hurst exponent H(t) using three-year moving time windows. In particular, we find that before the launch of the Collor Plan in 1990 the curve H(t) remains, in general, well above 1/2, while afterwards it stays close to 1/2. We thus argue that the structural reforms set off by the Collor Plan has lead to a more efficient stock market in Brazil. We also suggest that the time dependence of the Ibovespa Hurst exponent could be described in terms of a multifractional Brownian motion.
Two new gated x-ray imaging cameras have recently been designed, constructed, and delivered to the National Ignition Facility in Livermore, CA. These gated x-Ray detectors are each designed to fit within an aluminum airbox with a large capacity cooling plane and are fitted with an array of environmental housekeeping sensors. These instruments are significantly different from earlier generations of gated x-ray images due, in part, to an innovative impedance matching scheme, advanced phosphor screens, pulsed phosphor circuits, precision assembly fixturing, unique system monitoring, and complete remote computer control. Preliminary characterization has shown repeatable uniformity between imaging strips, improved spatial resolution, and no detectable impedance reflections.
Gated, microchannel-plate-based (MCP) framing cameras have been deployed worldwide for 0.2-9 keV x-ray imaging and spectroscopy of transient plasma phenomena. For a variety of spectroscopic and imaging applications, the angular sensitivity of MCPs must be known for correctly interpreting the data. We present systematic measurements of angular sensitivity at discrete relevant photon energies and arbitrary MCP gain. The results can been accurately predicted by using a simple 2D approximation to the 3D MCP geometry and by averaging over all possible photon ray paths.
A 1 mn-t square diamond photoconductive detector (PCD) has been installed on the LLNL Nova laser system, for use as a broad band soft x-ray power diagnostic. The PCD is installed behind an array of pinholes, which cast multiple, overlapping images of the source onto the diamond. This allows reduction of the x-ray intensity, to avoid saturation problems, while avoiding the spectral dependency of thin film filters. The diode current is read out on a 5 GHz bandwidth scope. The system is calibrated by comparison to an absolutely calibrated array of filtered vacuum x-ray photodiodes (XRD's) ("dante"). The time response of the PCD and its bias electronics have been characterized using the 5th harmonic (210 run) of a short pulse (< 1 ps) Ti:sapphire laser. The data show a fast rise, limited by the 5 GHz scope bandwidth, and a slower fall off, characterized by an RC time of order 200 ps. Abstract A 1 mm square diamond photoconductive detector (PCD) has been installed on the LLNL Nova laser system, for use as a broad band soft x-ray power diagnostic. The PCD is installed behind an array of pinholes, which cast multiple, overlapping images of the source onto the diamond. This allows reduction of the x-ray intensity, to avoid saturation problems, while avoiding the spectral dependency of thin film filters. The diode current is read out on a 5 GHz bandwidth scope. The system is calibrated by comparison to an absolutely calibrated array of filtered vacuum x-ray photodiodes (XRD's) ("dante"). The time response of the PCD and its bias electronics have been characterized using the 5th harmonic (210 nm) of a short pulse (< 1 ps) Ti:sapphire laser. The data show a fast rise, limited by the 5 GHz scope bandwidth, and a slower fall off, characterized by an RC time of order 200 ps.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.