Achromatically filtered diamond photoconductive detectors for high power soft x-ray flux measurements

Abstract: A 1 mn-t square diamond photoconductive detector (PCD) has been installed on the LLNL Nova laser system, for use as a broad band soft x-ray power diagnostic. The PCD is installed behind an array of pinholes, which cast multiple, overlapping images of the source onto the diamond. This allows reduction of the x-ray intensity, to avoid saturation problems, while avoiding the spectral dependency of thin film filters. The diode current is read out on a 5 GHz bandwidth scope. The system is calibrated by comparison t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

1999
1999
2024
2024

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 29 publications
(9 citation statements)
references
References 10 publications
0
9
0
Order By: Relevance
“…10 and 19 are equivalent; however, Eq. 19 gives T,(t) as a function of f~, fW, T~, and TW, quantities that can be directly measured as a function of time in a hohlraum experiment [83,[87][88][89][90][91][92][93][94][95][96][97][98][99][100][101][102][103][104][105][106].…”
Section: T (Xw and Qc-in Terms Of Directly-measurable Quantitiesmentioning
confidence: 99%
“…10 and 19 are equivalent; however, Eq. 19 gives T,(t) as a function of f~, fW, T~, and TW, quantities that can be directly measured as a function of time in a hohlraum experiment [83,[87][88][89][90][91][92][93][94][95][96][97][98][99][100][101][102][103][104][105][106].…”
Section: T (Xw and Qc-in Terms Of Directly-measurable Quantitiesmentioning
confidence: 99%
“…19 These x-ray diagnostics were used to confirm the time-, spatially, and spectrally dependent x-ray emission from the hohlraum walls and from the x-ray driven side of the ablator samples. The Dante diagnostic measures hohlraum x-ray reemission flux with an array of ten K-and L-edge filtered photocathode detectors with grazing incidence mirrors on some the low energy channels.…”
Section: Experimental Setup and Diagnostic Techniquesmentioning
confidence: 99%
“…9), with one LOS pipe section extending to 26 m. The LOS 5/6 diagnostics package is designed to provide the primary x-ray energy, power, and spectral measurements of the z-pinch itself. Five port locations exist and are typically used to field instruments including a bolometer array [67], an x-ray diode (XRD) array [68], a photoconducting detector (PCD) array [69][70][71], a transmission grating spectrometer (TGS) [43] (Fig. 10), and a total energy and power (TEP) diagnostic [72] or a calorimeter [73].…”
Section: Iii2 Upgrade Of the Los 5/6 Diagnostics Packagementioning
confidence: 99%
“…Diamond photoconducting detectors (PCDs) [69][70][71] are primary x-ray flux diagnostics on Z that feature fast, stable, flat response out to about 6 keV with a rugged, readily cleanable surface and very limited sensitivity to bremsstrahlung radiation. Initial attempts to calibrate the PCDs with NSLS and dc Henke x-ray sources resulted in unacceptably large error bars because of the variation of detector response across the surface and the spatial nonuniformity of the calibration sources.…”
Section: V2 Calibration Of Z-pinch X-ray Energy and Power Diagnosticsmentioning
confidence: 99%