The purpose of this work was to define all features, and show the potential, of the novel HYPERcollar applicator system for hyperthermia treatments in the head and neck region. The HYPERcollar applicator consists of (1) an antenna ring, (2) a waterbolus system and (3) a positioning system. The specific absorption rate (SAR) profile of this applicator was investigated by performing infra-red measurements in a cylindrical phantom. Mandatory patient-specific treatment planning was performed as an object lesson to a patient with a laryngeal tumour and an artificial lymph node metastasis. Comfort tests with healthy volunteers have revealed that the applicator provides sufficient comfort to maintain in treatment position for an hour: the standard hyperthermia treatment duration in our centre. By phantom measurements, we established that a central focus in the neck can be obtained, with 50% iso-SAR lengths of 3.5 cm in transversal directions (x/y) and 9-11 cm in the axial direction (z). Using treatment planning by detailed electromagnetic simulations, we showed that the SAR pattern can be optimised to enable simultaneous encompassing of a primary laryngeal tumour and a lymph node metastasis at the 25% iso-SAR level. This study shows that the applicator enables a good control, and sufficient possibilities for optimisation, of the SAR pattern. In an ongoing clinical feasibility study, we will investigate the possibilities of heating various target regions in the neck with this apparatus.
To apply high-quality hyperthermia treatment to tumours at deep locations in the head and neck (H&N), we have designed and built a site-specific phased-array applicator. Earlier, we demonstrated its features in parameter studies, validated those by phantom measurements and clinically introduced the system. In this paper we will critically review our first clinical experiences and demonstrate the pivotal role of hyperthermia treatment planning (HTP). Three representative patient cases (thyroid, oropharynx and nasal cavity) are selected and discussed. Treatment planning, the treatment, interstitially measured temperatures and their interrelation are analysed from a physics point of view. Treatments lasting 1 h were feasible and well tolerated and no acute treatment-related toxicity has been observed. Maximum temperatures measured are in the range of those obtained during deep hyperthermia treatments in the pelvic region but mean temperatures are still to be improved. Further, we found that simulated power absorption correlated well with measured temperatures illustrating the validity of our treatment approach of using energy profile optimizations to arrive at higher temperatures. This is the first data proving that focussed heating of tumours in the H&N is feasible. Further, HTP proved a valuable tool in treatment optimization. Items to improve are (1) the transfer of HTP settings into the clinic and (2) the registration of the thermal dose, i.e. dosimetry.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.