1999
DOI: 10.1016/s0167-8140(99)00143-7
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of a target contouring protocol for 3D conformal radiotherapy in non-small cell lung cancer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
69
1

Year Published

2003
2003
2014
2014

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 133 publications
(71 citation statements)
references
References 21 publications
1
69
1
Order By: Relevance
“…The range of standard deviations of interobserver variations in contoured target volumes determined in the present study was 6.8 to 35.3 cm 3 , agreeing with interobserver variations in PTV with standard deviations ranging from 4.86 to 99.92 cm 3 as reported by Senan et al ( 8 ) for target volumes in lung cancer. A target contouring protocol was designed by Senan et al for multi‐institutional trials to reduce lung target volume variation.…”
Section: Discussionsupporting
confidence: 92%
“…The range of standard deviations of interobserver variations in contoured target volumes determined in the present study was 6.8 to 35.3 cm 3 , agreeing with interobserver variations in PTV with standard deviations ranging from 4.86 to 99.92 cm 3 as reported by Senan et al ( 8 ) for target volumes in lung cancer. A target contouring protocol was designed by Senan et al for multi‐institutional trials to reduce lung target volume variation.…”
Section: Discussionsupporting
confidence: 92%
“…The study methodology, particularly intraobserver variation in contouring, may also contribute to the observed displacements [28] and this may be confounded by the absence of intravenous contrast in ABC scans hampering tumour outlining in or near the mediastinum. The use of rigid manual image registration in the first part of the study could also have introduced a small inaccuracy.…”
Section: Discussionmentioning
confidence: 99%
“…In these cases, however, delineation of the target volume was based on interpretation of the extent of tumor as displayed in an imaging study and not on the assessment of a particular anatomic structure. Prostate target volumes are notable exceptions, because the target volume is often the entire prostate 7 , 9 , 10 . For these cases, delineation of the target volume is tantamount to delineation of the prostate, and variations in the delineated target volume are the result of different interpretations of the extent of the anatomic structure.…”
Section: Introductionmentioning
confidence: 99%