One of the most pervasive problems afflicting people throughout the world is inadequate access to clean water and sanitation. Problems with water are expected to grow worse in the coming decades, with water scarcity occurring globally, even in regions currently considered water-rich. Addressing these problems calls out for a tremendous amount of research to be conducted to identify robust new methods of purifying water at lower cost and with less energy, while at the same time minimizing the use of chemicals and impact on the environment. Here we highlight some of the science and technology being developed to improve the disinfection and decontamination of water, as well as efforts to increase water supplies through the safe re-use of wastewater and efficient desalination of sea and brackish water.
A simple and effective method is presented for producing light-emitting porous silicon (PSi). A thin (d<10 nm) layer of Au, Pt, or Au/Pd is deposited on the (100) Si surface prior to immersion in a solution of HF and H2O2. Depending on the type of metal deposited and Si doping type and doping level, PSi with different morphologies and light-emitting properties is produced. PSi production occurs on the time scale of seconds, without electrical current, in the dark, on both p- and n-type Si. Thin metal coatings facilitate the etching in HF and H2O2, and of the metals investigated, Pt yields the fastest etch rates and produces PSi with the most intense luminescence. A reaction scheme involving local coupling of redox reactions with the metal is proposed to explain the metal-assisted etching process. The observation that some metal remains on the PSi surface after etching raises the possibility of fabricating in situ PSi contacts.
The extension of microfluidic devices to include three-dimensional fluidic networks allows complex fluidic and chemical manipulations but requires innovative methods to interface fluidic layers. Externally controllable interconnects, employing nuclear track-etched polycarbonate membranes containing nanometer-diameter capillaries, are described that produce hybrid three-dimensional fluidic architectures. Controllable nanofluidic transfer is achieved by controlling applied bias, polarity, and density of the immobile nanopore surface charge and the impedance of the nanocapillary array relative to the microfluidic channels. Analyte transport between vertically separated microchannels has three stable transfer levels, corresponding to zero, reverse, and forward bias. The transfer can even depend on the properties of the analyte being transferred such as the molecular size, illustrating the flexible character of the analyte transfer. In a specific analysis implementation, nanochannel array gating is applied to capillary electrophoresis separations, allowing selected separated components to be isolated for further manipulation, thereby opening the way for preparative separations at attomole analyte mass levels.
Desorption/ionization on porous silicon (DIOS) is a relatively new laser desorption/ionization technique for the direct mass spectrometric analysis of a wide variety of samples without the requirement of a matrix. Porous silicon substrates were fabricated using the recently developed nonelectrochemical H2O2-metal-HF etching as a versatile platform for investigating the effects of morphology and physical properties of porous silicon on DIOS-MS performance. In addition, laser wavelength, mode of ion detection, pH, and solvent contributions to the desorption/ionization process were studied. Other porous substrates such as GaAs and GaN, with similar surface characteristics but differing in thermal and optical properties from porous silicon, allowed the roles of surface area, optical absorption, and thermal conductivities in the desorption/ionization process to be investigated. Among the porous semiconductors studied, only porous silicon has the combination of large surface area, optical absorption, and thermal conductivity required for efficient analyte ion generation under the conditions studied. In addition to these substrate-related factors, surface wetting, determined by the interaction of deposition solvent with the surface, and charge state of the peptide were found to be important in determining ion generation efficiency.
Nanofluidic architectures and devices have already had a major impact on forefront problems in chemical analysis, especially those involving mass-limited samples. This critical review begins with a discussion of the fundamental flow physics that distinguishes nanoscale structures from their larger microscale analogs, especially the concentration polarization that develops at nanofluidic/microfluidic interfaces. Chemical manipulations in nanopores include nanopore-mediated separations, microsensors, especially resistive-pulse sensing of biomacromolecules, fluidic circuit analogs and single molecule measurements. Coupling nanofluidic structures to three-dimensional microfluidic networks is especially powerful and results in applications in sample preconcentration, nanofluidic injection/collection and fast diffusive mixing (160 references).
Molecular transport through nanoporous nuclear-track-etched membranes was investigated with fluorescent probes by manipulating applied electric field polarity, pore size, membrane surface functionality, pH, and the ionic strength. Three forces contribute to analyte transport through membranes: ion migration, electroosmosis, and diffusion. Diffusion dominates under field-free conditions with surface hydrophobicity controlling solvent access to the nanochannels and hence the magnitude of transport by diffusion. In low ionic strength solutions (µ ∼ 10 mM), electroosmosis dominates transport when the membranes are biased, and the charge state of the surface determines the direction of flow. At high ionic strength (µ ∼ 1 M), ion migration dominates in hydrophobic membranes, and diffusion is controlling in hydrophilic membranes. The magnitude and polarity of the interior surface charge is controlled by surface functionality and displays the largest impact on molecular transport. The analyte can migrate in opposite directions under the same applied electric field by modifying either membrane surface charge or solution ionic strength. Transport can be fine-tuned by adjusting pH under low ionic strength conditions in either type of membrane. Increasing the surface charge density, σs, enhances the mobile counterion concentration, increasing the electroosmotically driven flux. Comparisons of behavior under different conditions are understood by reference to the product, κa, of the inverse Debye length, κ, and the pore diameter, a.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.