Electronic cigarettes (ECs) are nicotine delivery devices that are proposed as tobacco harm reduction products to smokers. Nicotine delivery from ECs is potentially important in their efficacy as smoking substitutes. Herein, nicotine delivery from using a new-generation EC device (variable-wattage, set at 9 W) was evaluated, comparing experienced (vapers) with naïve users (smokers). Twenty-four vapers and 23 smokers participated to the study. They were asked to obtain 10 puffs in 5 minutes and then use the EC ad lib for 60 more minutes (total duration of use: 65 minutes). An 18 mg/mL nicotine-containing liquid was used. Blood samples were obtained at baseline, 5-minutes and every 15 minutes thereafter, while number of puffs and average puff duration were recorded. Although at baseline both groups had similar plasma nicotine levels, smokers consistently exhibited lower levels at all time-periods; at 5-minutes the levels were lower by 46%, while during the subsequent period they were lower by 43% (at 65-minutes) to 54% (at 20-minutes). Both groups took similar number of puffs, but smokers had average puff duration of 2.3 s compared to 3.5 s in vapers. Even in vapers, plasma nicotine levels at 5 minutes were lower than those observed after smoking 1 tobacco cigarette.
Aims The purpose of this study is to identify echocardiography predictors of clinical response and reverse left ventricular (LV) remodelling in patients with functional mitral regurgitation (FMR) treated with MitraClip. Method and results We retrospectively analysed 86 high surgical risk patients with severe FMR; of those, 58 were implanted a MitraClip, and 28 received medical treatment and served as controls. At baseline and at 1-year follow-up, we performed clinical and echocardiography evaluation to assess global longitudinal strain (GLS) and myocardial work [global work index (GWI), global constructive work (GCW), global wasted work (GWW), global work efficiency (GWE)]. Mitral regurgitation was significantly reduced after MitraClip implantation (3.7 ± 0.4 vs. 1.7 ± 0.8, P < 0.001), and the procedure was associated with improvement in brain natriuretic peptide levels (980 ± 1027 vs. 420 ± 338 pg/mL, P < 0.001), New York Heart Association class status (3.2 ± 0.55 vs. 2.0 ± 0.6, P < 0.001), 6-min walking test (233 ± 154 vs. 286 ± 114 m, P = 0.01) at follow-up and reduction of left ventricle end-systolic (LVESV) and left ventricle end-diastolic volumes (LVEDV) (152 ± 68 vs. 136 ± 43 mL, P = 0.004 & 219 ± 74 vs. 193 ± 66 mL, P = 0.001, respectively). MitraClip procedure was associated with improvement of LV performance and significant increase of GWI (607 ± 282 vs. 650 ± 260 mmHg%, P = 0.045) and GCW (854 ± 288 vs. 949 ± 325 mmHg%, P < 0.001). Baseline ejection fraction (EF), GLS, GWI, GCW, and effective regurgitant orifice area were the variables that were associated with reduction of LVEDV 1 year after intervention (P < 0.05 for all) and baseline GCW of the LV was the only variable associated with reduction of LVESV (P = 0.002). Receiver operating characteristic curve analysis identified that a GLS cutoff value of À8.65% (AUC 0.815, P = 0.007) was associated with a 20% reduction of the LVEDV with a sensitivity and specificity of 72% and 70%, respectively, and that a GCW cutoff value of 846 mmHg% (AUC 0.759, P = 0.007) was associated with a 10% reduction of LVESV with sensitivity and specificity 79% and 74%, respectively. Conclusions Mitral valve repair with MitraClip has positive clinical and echocardiographic impact in patients with FMR 1 year after implantation. Preserved GLS and GCW values appear to be associated with LV reverse remodelling post intervention.
The incidence of depressive symptomatology in patients with CHD is rather high and is associated with poorer prognosis. The BDI seems to independently predict adverse clinical outcome. Standardized screening tools and psychosocial interventions to improve the well being of these patients should be a priority in the overall care of this population.
Carotid atherosclerosis represents a primary cause for cerebrovascular ischemic events and its contemporary management includes surgical revascularization for moderate to severe symptomatic stenoses. However, the role of invasive therapy seems to be questioned lately for asymptomatic cases. Numerous reports have suggested that the presence of neovessels within the atherosclerotic plaque remains a significant vulnerability factor and over the last decade imaging modalities have been used to identify intraplaque neovascularization in an attempt to risk-stratify patients and offer management guidance. Contrast-enhanced ultrasonography of the carotid artery is a relatively novel diagnostic tool that exploits resonated ultrasound waves from circulating microbubbles. This property permits vascular visualization by producing superior angiography-like images, and allows the identification of vasa vasorum and intraplaque microvessels. Moreover, plaque neovascularization has been associated with plaque vulnerability and ischemic symptoms lately as well. At the same time, attempts have been made to quantify contrast-enhanced ultrasonography signal using sophisticated software packages and algorithms, and to correlate it with intraplaque microvascular density. The aim of this review was to collect all recent data on the characteristics, performance, and prognostic role of contrast-enhanced ultrasonography regarding carotid stenosis management, and to produce useful conclusions for clinical practice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.