The performance of two knee simulators designed by ProSim (Manchester, UK) was evaluated by comparison of the wear seen in the press-fit condylar (PFC) Sigma (DePuy) knee prosthesis. Twelve specimens of the same design and manufacturing specification, were subjected to a wear test of 2 x 10(6) cycles duration using bovine serum as a lubricant. The anterior/posterior displacement and internal/external rotation inputs were based on the kinematics of the natural knee. International Standards Organization (ISO) standards were used for the flexion and axial load. The wear rates and wear scar areas were compared across all stations. The mean wear rates found were 17.6+/-5 mm3/10(6) cycles for stations 1 to 6 and 19.6+/-4 mm3/10(6) cycles for stations 7 to 12, resulting in an overall mean wear rate of 18.1+/-3 mm3/10(6) cycles. The differences between the two simulators were not significant. The average wear scar area seen on inserts from stations I to 6 was calculated at 32.4+/-1 per cent of the intended articulating surface. Similarly on stations 7 to 12 the average wear scar area was 30.7+/-3 per cent. The wear scars seen were a good physiological representation of those found from clinical explant data. This study has shown good repeatability from the simulator, both within and between the simulators.
This study isolated and characterized UHMWPE particles from 3 explant groups: early Charnley hip failures (ECE; < 10 years), late Charnley hip failures (LCE; > 10 years) and early knee failures (EKE; < 10 years). Debris isolated from the 3 groups had percentage particle number and percentage volumetric concentration distributions that were not significantly different. The greatest number of particles were found in the 0.1-0.5 microm size range and 19-20.6% of the volumetric concentration was below 1 microm in size in all groups. However, there were significant differences in the total volumetric concentration of debris isolated per g of tissue. LCE had significantly higher volumes of debris than ECE and EKE, there was no significant difference in the volume of debris from the EKE and ECE. The mean aspect ratio and mean irregularity ratio of the LCE group were also significantly higher than the ECE and EKE, suggesting that different wear mechanisms were occurring in the late Charnley group compared to the early Charnley and knee groups. These results also suggest that early knees, with normal surface wear, may have similar wear mechanisms to early Charnley hips and indicate that similar volumes of biologically active micrometer and sub-micrometer UHMWPE particles were produced. This may have important implications in the longer-term outcome of total knee arthroplasties, because it indicates a similar potential for osteolysis induced by wear debris.
This study isolated and characterized UHMWPE particles from 3 explant groups: early Charnley hip failures (ECE; < 10 years), late Charnley hip failures (LCE; > 10 years) and early knee failures (EKE; < 10 years). Debris isolated from the 3 groups had percentage particle number and percentage volumetric concentration distributions that were not significantly different. The greatest number of particles were found in the 0.1-0.5 m size range and 19 -20.6% of the volumetric concentration was below 1 m in size in all groups. However, there were significant differences in the total volumetric concentration of debris isolated per g of tissue. LCE had significantly higher volumes of debris than ECE and EKE, there was no significant difference in the volume of debris from the EKE and ECE. The mean aspect ratio and mean irregularity ratio of the LCE group were also significantly higher than the ECE and EKE, suggesting that different wear mechanisms were occurring in the late Charnley group compared to the early Charnley and knee groups. These results also suggest that early knees, with normal surface wear, may have similar wear mechanisms to early Charnley hips and indicate that similar volumes of biologically active micrometer and sub-micrometer UHM-WPE particles were produced. This may have important implications in the longer-term outcome of total knee arthroplasties, because it indicates a similar potential for osteolysis induced by wear debris.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.