Optimal Network Reconfiguration (NR) is a well-accepted approach to minimize power loss and enhance voltage profile in the Electrical Distribution Networks (EDN). Since the NR problem contains huge combinational search space, most researchers consider the meta-heuristic techniques to attain NR solution. However, these meta-heuristic techniques do not guarantee to obtain the optimal solution besides they require large processing time to converge. This is mainly due to (1) random initialization and updating of population and (2) the continuous verification of population during the search process. With the aim of reducing the computational time and improving the consistency in obtaining the optimal solution as well as minimizing power loss and enhancing the voltage profile of the EDN, this work proposes a new method based on two-stage optimizations. The proposed method introduces an approach to simplify the network into simplified network graph. Then, this approach is utilized for guided initializations and generations of the population and for the proper population's codification. The proposed method is implemented using the firefly algorithm and verified on 33-bus and 118-bus test systems. The results show the ability of the proposed method to obtain the optimal solution within fast computational time and with superior consistency compared to the conventional methods.
This paper proposed an improved structure of Proportional Integral Derivative (PID) controller called as Integral Proportional Derivative (I-PD), applied for Automatic Generation Control (AGC) of Multi-Source Interconnected Power System (IPS). The parameters of the proposed controller are optimized with a newly developed, powerful, nature-inspired meta-heuristic technique known as Fitness Dependent Optimizer (FDO). To show the efficacy of the proposed controller and the technique used, they have been tested on three different system models. Initially, a two-equal area of diverse source generation including reheat-thermal, gas, and hydro power system is considered. In the second scenario, the same power system model is used with addition of two non-linearities; Generation Rate Constraint (GRC) and Governor Dead Band (GDB). Lastly, multiple non-linearities including Governor Dead Band (GDB), Time Delay (TD), Generation Rate Constraint (GRC), and Boiler Dynamics (BD) have been considered to make the initial system more realistic and practical. The outcome from the proposed techniques is also compared with some recently meta-heuristic algorithms such as Teaching Learning Based Optimization (TLBO), Particle Swarm Optimization (PSO) and Firefly Algorithm (FA). From the results, it has been perceived that the proposed technique shows superior performance in respect of Overshoot (Osh), Undershoot (Ush) and Settling Time (Ts) of the system frequency.
Technology advancement for renewable energy resources and its integration to the distribution network (DN) has garnered substantial interest in the last few decades. Integrating such resources has proven to reduce power losses and improve the reliability of DN. However, the growing number of these resources in DN has imposed additional operational and control issues in voltage regulation, system stability, and protection coordination. Incorporation of various types of distributed generators (DG) into DN causes significant changes in the system. These including new fault current sources, new fault levels, a blinding effect in the protection scheme, reduction in the reach of relays, and decrement in the detection of lowlevel fault currents for existing relays. Such changes will jeopardize the effectiveness of the entire protection scheme in the DN. This research aims to propose a robust protection scheme in which the relay coordination settings are optimized based on the network layout. The potential impacts of DGs on the DN are mitigated by utilizing a user-defined overcurrent-based relay characteristic to obtain the minimum operating time while satisfying protection coordination constraints. A hybrid optimization algorithm based on Metaheuristic and Linear Programming that has the capability to attain the optimal solution and reduces computational time is proposed in this work. The performance of the proposed technique is tested on radial DN integrated with microgrid (MG). The results obtained show the proposed technique has successfully reduced the relay operating time while meeting the protection coordination requirements for dynamic operating modes of a network.
This paper presents a Fractional Order Integral-Proportional Derivative (FOI-PD) controller for Automatic Generation Control (AGC) of two-area Interconnected Power System (IPS) with six multiple generations units in a restructured environment. Further, the two-area IPS is composed of multiple nonlinearities with Time Delay (TD), Boiler Dynamic (BD), Governor Dead Zone/ Band (GDZ/ GDB) and Generation Rate Constraint (GRC). The gains of the proposed controller are optimized by a most recent powerful meta-heuristic algorithm known as Improved-Fitness Dependent Optimizer (I-FDO). The efficiency of the proposed approach is compared with other techniques such as Firefly Algorithm (FA), Fitness Dependent Optimizer (FDO) and Teaching Learning Based Optimization (TLBO) algorithms. Further, to enhance the performance of the system, Redox Flow Batteries (RFB) is incorporated in each area and Thyristor Controlled Series Compensator (TCSC) in the tie-line of the power system. Results reveal that our proposed approach performs superior in terms of less Overshoot (Os), Settling time (Ts) and Undershoot (Us). Robustness of the proposed controller is verified by changing system parameters within a range of ± (25) %.
Modern societies these days are more dependent on electrical energy and they expect a continuous supply as per demand. In this regard, the complex power system is designed to supply electrical energy with a certain level of quality and continuity though it is still susceptible to vandalism, natural disasters, and extreme weather. The black sky event where the power grid goes down is more of a possibility nowadays than ever due to more frequent severe weather events. This in turn has increased the need to study resilience in the context of the power system. This study presents a comprehensive review of the literature on power system resilience from various perspectives. First, well‐developed power system safety concepts are discussed and critically reviewed in view of large‐scale power outages. Then, the various definitions and confounding features of resilience in the power system domain are presented. Subsequently, several frameworks, resilience curves, and quantitative metrics proposed in recent years for power system resilience are investigated, followed by a summary of hardening strategies. Next, a case study is presented to illustrate how the resilience of a 69‐bus system is assessed against a hurricane. Finally, the study highlights challenges and proposes several future works to achieve a resilient power grid.
Technology advancement in the last few decades allows large penetration of renewable energy resources in the distribution network (DN). The integration of such resources has shown a substantial impact on DN through power loss reduction and improved network reliability. Besides this, the existing protection system has encountered coordination challenges due to the bidirectional power flow, different types and capacity of generation sources, and changes in fault levels due to network operating modes (grid-connected or islanded). Such conditions may cause the relays to malfunction and imperil the effectiveness of the existing protection scheme. Therefore, an efficient and robust protection coordination scheme is imperative to avoid network reliability and stability issues to the grid. This review paper presents a comparative analysis of various protection techniques implemented to alleviate the impact of integrated resources into DN. Moreover, a comparison of classical and modified protection approaches in terms of advantages, shortcomings, and implementation costs is presented. The prime objective of this study is to highlight the prominence of utilizing user-defined programmable relays for modern DNs. Moreover, recommendations are presented by considering the application of user-defined relay characteristics that can be proved as a robust protection scheme to cope with the protection challenges in existing and future power systems developments.INDEX TERMS Distribution networks (DN), microgrids (MG), protection coordination scheme, renewable energy resources (RES), user-defined characteristics (UDC).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.