In situ phosphorous MRS was employed to study the metabolites of normal and cancerous breasts, and the alterations of tumor response to therapy. In a group of 7 normal volunteers and 12 patients, the total mobile phosphate content of breast carcinomas was found to be at least two to three times higher than that of the normal breast measured off menstruation. The metabolite profiles of normal and tumorous breasts are coarsely similar. In both cases the intracellular pH (pHi) was either neutral or slightly alkaline (pH greater than 7.0). Prior to treatments, the metabolite levels of phosphoryl monoester-to-ATP ratio of breast neoplasms were higher than those of the controls and decreased after the patients received a few treatments while the pHi fluctuated at a value greater than 7.0. The phosphoryl diester-to-ATP ratio also demonstrated to a lesser extent a decreasing trend in response to therapy.
Pan T, helper, and cytotoxic lymphocytes were isolated from the human peripheral blood mononuclear cell fraction by antibody staining, ferritin labeling, and deposition on glass slides. Two distinct forms of ferritin were used: one was native horse spleen ferritin, and the other was magnetoferritin. Magnetoferritin was obtained by reconstituting the horse spleen ferritin iron core with superparamagnetic magnetite instead of the usual paramagnetic ferrihydrite crystal. The cell deposition on microscopic glass slides in the magnetic field was obtained by an instrument that was adapted from an industrial magnetic deposition analyzer, the ferrograph. The identity of cells in the magnetic deposits was confirmed by comparing the cell fractions in the feed and in the eluate with the use of flow cytometry. The immunostaining protocol amplified the number of ferritin molecules per cell surface antigen 20-70 times. Magnetoferritin, but not native ferritin, imparted a sufficient magnetic moment to cells to deplete the labeled cell population between 67 and 88% of its initial concentration in a magnetic field of 1.67 Tesla (T), a field gradient of 2.57 T/mm, and a flow rate of 0.01 ml/min. This study showed that the magnetic moment of magnetoferritin was sufficient for immunomagnetic isolation of lymphocytes from mononuclear cell preparations in the modified ferrograph.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.