Multiparametric magnetic resonance imaging (MP-MRI) has emerged as a promising method for the detection of prostate cancer. The functional MRI components of the MP-MRI consist of the diffusion weighted MRI, dynamic contrast enhanced MRI, and magnetic resonance spectroscopic imaging. The purpose of this paper is to review the existing literature about the use of functional MRI in prostate cancer detection.
Acute pathology of the biliary tract including cholangitis and cholecystitis can lead to biliary sepsis if early decompression is not performed. This article provides an overview of the presenting signs and symptoms and role of interventional radiology in the management of patients with acute cholangitis or acute cholecystitis. It is especially important to understand the role of IR in the context of other treatment options including medical management, endoscopy, and surgery.
Purpose. To determine to what extent an inflatable endorectal coil (ERC) affects whole prostate (WP) volume and shape during prostate MRI. Materials and Methods. 79 consecutive patients underwent T2W MRI at 3T first with a 6-channel surface coil and then with the combination of a 16-channel surface coil and ERC in the same imaging session. WP volume was assessed by manually contouring the prostate in each T2W axial slice. PSA density was also calculated. The maximum anterior-posterior (AP), left-right (LR), and craniocaudal (CC) prostate dimensions were measured. Changes in WP prostate volume, PSA density, and prostate dimensions were then evaluated. Results. In 79 patients, use of an ERC yielded no significant change in whole prostate volume (0.6 ± 5.7%, P = 0.270) and PSA density (−0.2 ± 5.6%, P = 0.768). However, use of an ERC significantly decreased the AP dimension of the prostate by −8.6 ± 7.8% (P < 0.001), increased LR dimension by 4.5 ± 5.8% (P < 0.001), and increased the CC dimension by 8.8 ± 6.9% (P < 0.001). Conclusion. Use of an ERC in prostate MRI results in the shape deformation of the prostate gland with no significant change in the volume of the prostate measured on T2W MRI. Therefore, WP volumes calculated on ERC MRI can be reliably used in clinical workflow.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.