These results indicate that RNFL and macula thickness, as well as macula volume measurements are reduced in schizophrenic patients. The degree of thinning and reduction was more significant in the chronic phase of the disease and correlated with the duration of illness. These findings demonstrate that SD-OCT can be a useful tool for the diagnosis and monitoring the progression of this disease.
We conclude that about half of patients had diagnostic constrictive bronchiolitis, or bronchiolectasis and mucus stasis consistent with more proximal luminal compromise. The fact that there were no differences between the low- and high-dose groups suggests that effects of SM are not solely dependent on the severity of exposure. The results also indicate that the diagnosis of chronic lung disease due to SM may be difficult. Surgical lung biopsy may be helpful in difficult cases, as constrictive (obliterative) bronchiolitis can be present in symptomatic patients with normal PFTs and chest HRCT.
Although sulfur mustard (SM) has been used as a chemical warfare agent since the early twentieth century, it has reemerged in the past decade as a major threat around the world. This agent injured over 100,000 Iranians and one-third is suffering from late effects until today. Mustard affects many organs such as the skin, eyes, and lungs, as well as the gastrointestinal, endocrine, and hematopoietic system. In this study we focused on review of the late Cutaneous and ocular complications caused by exposure to SM. All studies regarding long-term ocular and cutaneous effects, which have been done on Iranian population, were collected from domestic and international sources. Pruritus is the most common complain and a malignant change is the most important lesion, which has to be considered. Also this agent is causes of chronic and delayed destructive lesions in the ocular surface and cornea, leading to progressive visual deterioration and ocular irritation.
Tracheobronchomegaly (TBM) (Mounier-Kuhn syndrome) is dilatation of the trachea and major bronchi because of atrophy or absence of elastic fibers and smooth muscle cells. We present a case of TBM with normal pulmonary function test (PFT). The patient was a 37-year-old man with increasing productive cough and without fever, wheezes, chest pain, weight loss or any respiratory disease. Chest helical computed tomography (CT) scan showed tracheomegaly with transversal diameters of the trachea of 44mm. CT scan showed collapse of the trachea. Few large diverticular out-pouching and openings in the trachea was seen in bronchoscopy. PFT results were normal. PFT in large airway disorders may be normal while abnormalities may indicate underlying small airway disorder. An underlying small airway disorders is responsible for abnormal reports in PFT of these patients. We may need to re-evaluate the role of PFT within follow-up of patients with large airway disorder.
Background. Our study aimed to investigate an association between ocular pseudoexfoliation (PXF) and sensorineural hearing loss (SNHL) and to compare them with age and sex matched controls without pseudoexfoliation. Method. This was a case-control study of 123 patients which included 68 cases with PXF (at least one eye) and 55 controls without pseudoexfoliation. Pure-tone audiometry (PTA) was done for these patients at sound frequencies taken as important for speech comprehension, that is, 250 Hertz (Hz), 500 Hz, 1000 Hz, and 2000 Hz. Results. There were 41 patients with pseudoexfoliation syndrome (PXE) and 27 with pseudoexfoliative glaucoma (PXEG). The majority of patients with hearing loss (60%; n = 51) were PXF patients and the remaining 40% (n = 34) were controls. Below average hearing thresholds were significantly higher in the pseudoexfoliation group compared to the control group (P = 0.01; odds ratio (OR), 3.00; 95% confidence interval (CI), 1.25–7.19). However, there was no significant difference in the mean hearing threshold levels between the three groups (PXE, PXEG, and controls) in either ear (ANOVA, right ear: P = 0.46 and left ear P = 0.36). Conclusion. Our study found an association between PXF and SNHL, confirming that PXF can involve organs in the body other than the eye.
PurposeTo compare the performance of OKULIX ray-tracing software with SRK-T and Hoffer Q formula in intraocular lens (IOL) power calculation in patients presenting with cataract.MethodsIn this prospective study, 104 eyes of 104 patients with cataract who underwent phacoemulsification and IOL implantation were recruited. Three IOL brands were used and for all eyes, IOL power calculation was performed using SRK-T, Hoffer Q formula and also OKULIX ray-tracing software. For all patients, axial length and keratometry data was obtained with IOLMaster 500 device and IOL power was determined using Hoffer Q and SRK-T formula. The IOL powers were also calculated using the OKULIX ray-tracing software combined with CASIA AS-OCT and IOLMaster 500 device. Optically measured axial length of eyes were inserted to OKULIX software from IOLMaster 500 device, and anterior and posterior tomographic and corneal pachymetry data was imported from CASIA AS-OCT into the OKULIX.The performance of each calculation methods was measured by subtracting the predicted postoperative refraction from the postoperative manifest refraction spherical equivalent (MRSE). For each of the 3 methods, the mean absolute prediction error was determined, too.ResultsThe mean value absolute prediction error by OKULIX, SRK-T and Hoffer Q formulas, respectively, were 0.42 (±0.03), 0.36 (±0.02) and 0.37 (±0.02). The mean absolute prediction error by OKULIX had no significant difference between three IOL groups (P = 0.96), and it was confirmed that there was no meaningful statistically difference in mean absolute prediction error between the OKULIX, SRK-T and Hoffer Q formula. (P = 0.25). Also in each group of implanted IOLs, all three formulas worked with the same accuracy. The prediction error using OKULIX were within ±0.50 diopter in 63.5% of eyes and within ±1.00 diopter in 94.2% of eyes.ConclusionOKULIX ray-tracing IOL power measurements provides reliable and satisfactory postoperative results, which are comparable to other 3rd generation formulas of SRK-T and Hoffer Q.
MRI measured optic nerve volume is a reliable method of assessing glaucomatous damage beyond the optic nerve head. A value of 236 mm(3) and below can be used to define severe glaucoma.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.