Here for the first time, we detail self-contained (wireless and self-powered) biodevices with wireless signal transmission. Specifically, we demonstrate the operation of self-sustained carbohydrate and oxygen sensitive biodevices, consisting of a wireless electronic unit, radio transmitter and separate sensing bioelectrodes, supplied with electrical energy from a combined multi-enzyme fuel cell generating sufficient current at required voltage to power the electronics. A carbohydrate/oxygen enzymatic fuel cell was assembled by comparing the performance of a range of different bioelectrodes followed by selection of the most suitable, stable combination. Carbohydrates (viz. lactose for the demonstration) and oxygen were also chosen as bioanalytes, being important biomarkers, to demonstrate the operation of the self-contained biosensing device, employing enzyme-modified bioelectrodes to enable the actual sensing. A wireless electronic unit, consisting of a micropotentiostat, an energy harvesting module (voltage amplifier together with a capacitor), and a radio microchip, were designed to enable the biofuel cell to be used as a power supply for managing the sensing devices and for wireless data transmission. The electronic system used required current and voltages greater than 44 µA and 0.57 V, respectively to operate; which the biofuel cell was capable of providing, when placed in a carbohydrate and oxygen containing buffer. In addition, a USB based receiver and computer software were employed for proof-of concept tests of the developed biodevices. Operation of bench-top prototypes was demonstrated in buffers containing different concentrations of the analytes, showcasing that the variation in response of both carbohydrate and oxygen biosensors could be monitored wirelessly in real-time as analyte concentrations in buffers were changed, using only an enzymatic fuel cell as a power supply.
In this paper, we present a novel approach for preparing patterned Au/poly(dimethylsiloxane) (PDMS) substrate. Chemical gold plating instead of conventional metal evaporation or sputtering was introduced to achieve a homogeneous gold layer on native PDMS for the first time, which possesses low-cost and simple operation. An electrochemical oxidation reaction accompanied by the coordination of gold and chloride anion was then exploited to etch gold across the region covered by electrolyte. On the basis of such an electrochemical etching, heterogeneous Au/PDMS substrate which has a gold "island" pattern or PDMS dots pattern was fabricated. Hydrogen bubbles which were generated in the etching process due to water electrolysis were used to produce a safe region under the Pt auxiliary electrode. The safe region would protect gold film from etching and lead to the formation of the gold "island" pattern. In virtue of a PDMS stencil with holes array, gold could be etched from the exposed region and take on the PDMS dots pattern which was selected to for protein and cell patterning. This patterned Au/PDMS substrate is very convenient to construct cytophobic and cytophilic regions. Self-assembled surface modification of (1-mercaptoundec-11-yl)hexa(ethylene glycol) on gold and adsorption of fibronectin on PDMS are suitable for effective protein and cell patterning. This patterned Au/PDMS substrate would be a potentially versatile platform for fabricating biosensing arrays.
After initial testing and optimization of anode biocatalysts, a membraneless glucose/oxygen enzymatic biofuel cell possessing high coulombic efficiency and power output was fabricated and characterized. Two sugar oxidizing enzymes, namely, pyranose dehydrogenase from Agaricus meleagris (AmPDH) and flavodehydrogenase domains of various cellobiose dehydrogenases (DH(CDH)) were tested during the pre-screening. The enzymes were mixed, "wired" and entrapped in a low-potential Os-complex-modified redox-polymer hydrogel immobilized on graphite. This anode was used in combination with a cathode based on bilirubin oxidase from Myrothecium verrucaria adsorbed on graphite. Optimization showed that the current density for the mixed enzyme electrode could be further improved by using a genetically engineered variant of the non-glycosylated flavodehydrogenase domain of cellobiose dehydrogenase from Corynascus thermophilus expressed in E. coli (ngDH(CtCDHC310Y)) with a high glucose-turnover rate in combination with an Os-complex-modified redox polymer with a high concentration of Os complexes as well as a low-density graphite electrode. The optimized biofuel cell with the AmPDH/ngDH(CtCDHC310Y) anode showed not only a similar maximum voltage as with the biofuel cell based only on the ngDH(CtCDHC310Y) anode (0.55 V) but also a substantially improved maximum power output (20 μW cm(-2)) at 300 mV cell voltage in air-saturated physiological buffer. Most importantly, the estimated half-life of the mixed biofuel cell can reach up to 12 h, which is apparently longer than that of a biofuel cell in which the bioanode is based on only one single enzyme.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.