Although commercial linear array transducers are widely used in clinical ultrasound, their application in photoacoustic tomography (PAT) is still limited due to the limited-view problem that restricts the image quality. In this paper, we propose a simple approach to address the limited-view problem in 2D by using two linear array transducers to receive PAT signal from different orientations. The positions of the two transducers can be adjusted to fit the specific geometry of an imaging site. This approach is made possible by using a new calibration method, where the relative position between the two transducers can be calibrated using ultrasound by transmitting ultrasound wave with one transducer while receiving with the other. The calibration results are then applied in the subsequent PAT imaging to incorporate the detected acoustic signals from both transducers and thereby increase the detection view. In this calibration method, no calibration phantom is required which largely simplifies and shortens the process. The efficacy of the calibration and improvement on the PAT image quality are demonstrated through phantom studies and in vivo imaging.
In vivo imaging of prostate cancer with photoacoustic tomography is currently limited by the lack of sufficient local fluence for deep tissue penetration and the risk of overirradiation near the laser-tissue contact surface. We propose the design of a transurethral illumination probe that addresses those limitations. A high energy of 50 mJ/pulse is coupled into a 1000-µm-core diameter multimode fiber. A 2 cm diffusing end is fabricated, which delivers light in radial illumination. The radial illumination is then reflected and reshaped by a parabolic cylindrical mirror to obtain nearly parallel side illumination with a doubled fluence. The fiber assembly is housed in a 25 Fr cystoscope sheath to provide protection of the fiber and maintain a minimal laser-tissue contact distance of 5 mm. A large laser-tissue contact surface area of 4 cm 2 is obtained and the fluence on the tissue surface is kept below the maximum permissible exposure. By imaging a prostate mimicking phantom, a penetration depth of 3.5 cm at 10 mJ/cm 2 fluence and 700 nm wavelength is demonstrated. The results indicate that photoacoustic tomography with the proposed transurethral probe has the potential to image the entire prostate while satisfying the fluence maximum permissible exposure and delivering a high power to the tissue.
In photoacoustic tomography (PAT), delivering high energy pulses through optical fiber is critical for achieving high quality imaging. A fiber coupling scheme with a beam homogenizer is demonstrated for coupling high energy pulses in a single multimode fiber. This scheme can benefit PAT applications that require miniaturized illumination or internal illumination with a small fiber. The beam homogenizer is achieved by using a cross cylindrical lens array, which provides a periodic spatial modulation on the phase of the input light. Thus the lens array acts as a phase grating which diffracts the beam into a 2D diffraction pattern. Both theoretical analysis and experiments demonstrate that the focused beam can be split into a 2D spot array that can reduce the peak power on the fiber tip surface and thus enhance the coupling performance. The theoretical analysis of the intensity distribution of the focused beam is carried out by Fourier optics. In experiments, coupled energy at 48 mJ/pulse and 60 mJ/pulse have been achieved and the corresponding coupling efficiency is 70% and 90% in a 1000-μm and a 1500-μm-core-diameter fiber, respectively. The high energy pulses delivered by the multimode fiber are further tested for PAT imaging in phantoms. PAT imaging of a printed dot array shows a large illumination area of 7 cm under 5 mm thick chicken breast tissue. In vivo imaging is also demonstrated on the human forearm. The large improvement in coupling energy can potentially benefit PAT with single fiber delivery to achieve large area imaging and deep penetration detection.
. Significance: As linear array transducers are widely used in clinical ultrasound imaging, photoacoustic tomography (PAT) with linear arrays is similarly suitable for clinical applications. However, due to the limited-view problem, a linear array has limited performance and leads to artifacts and blurring, which has hindered its broader application. There is a need to address the limited-view problem in PAT imaging with linear arrays. Aim: We investigate potential approaches for improving PAT reconstruction from linear array, by optimizing the detection geometry and implementing iterative reconstruction. Approach: PAT imaging with a single-array, dual-probe configurations in parallel-shape and L-shape, and square-shape configuration are compared in simulations and phantom experiments. An iterative model-based algorithm based on the variance-reduced stochastic gradient descent (VR-SGD) method is implemented. The optimum configuration found in simulation is validated on phantom experiments. Results: PAT imaging with dual-probe detection and VR-SGD algorithm is found to improve the limited-view problem compared to a single probe and provide comparable performance as full-view geometry in simulation. This configuration is validated in experiments where more complete structure is obtained with reduced artifacts compared with a single array. Conclusions: PAT with dual-probe detection and iterative reconstruction is a promising solution to the limited-view problem of linear arrays.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.